move some initialization from cfg file to source code
+ make 'out of calibrated range' and 'sensor break' more generic
Change-Id: I3e92100fdb9c983f82665de9d8e063609cd7af5a
+ visibiliy is no longer an EnumType, as this would break
the specs
Change-Id: I1197c82f31c33c210fdcda0b49a0c38027880d77
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/36088
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
take the opportunity for a small redesign:
- create a new method build_descriptive_data which
calls secnode.get_modules also on unexported modules.
+ cache descriptive data
Change-Id: I4a0b8ac96108463dc0c800bb11a404206c26b092
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/36089
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
- new config file dummy
- frappy_demo.test.Temp now creates WARN and ERROR status
and may be disabled
Change-Id: Ibc7bb565f18c2c12cdc2a77bea1ee1bf1cc8bd41
- add name when target and value datatype are incompatible
- check that module class inherits from Module
Change-Id: I4edbdff1c250b64b74b1adf7287f9659dff69b26
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35931
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
a property declared in a base class may be overriden
with a parameter in a subclass. this is already allowed.
if then, in the subsubclass it is overridden by a bare value,
it fails.
Patchset 1: add a test for this
Patchset 4: add the fix
Change-Id: Ia5a26076a9ee98439932643a03878342d56f8396
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35932
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
- new classes in frappy_psi/ultrasound.py and frappy_psi/adq.mr.py
- add signal plottter
- move clients to bin/ directory
Change-Id: I8db8e5ebc082c346278f09e0e54504e070655f14
make sure module methods are not called after shutdownModule
+ fix: when mod.enablePoll is False, pollInfo is None
therefore we have to check before access
Change-Id: I83b28607b25996376939175be8abf0c5b27bcac1
The Parameter Properties 'value', 'default' and 'constant'
have ValueType, so they are not checked in the setProperty call.
We have to do this explicitly in Module._add_accessible.
Change-Id: I1e35adf2fe539411b4aebacd813adb07497de95b
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35797
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
The test for method names 'read_<param>' and 'write_<param>'
without a defined parameter is simplified. We do not check
anymore method names from base classes. Base classes
inheriting from HasAccessible are checked anyway at the
place they are defined.
+ add a test for it
+ move some tests to a new file test_all_modules.py, as
test_modules.py is getting too long
+ fix missing doc string (frappy.simulation.SimDrivable.stop)
Change-Id: Id8a9afe5c977ae3b1371bd40c6da52be2fc79eb9
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35503
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>