The test for method names 'read_<param>' and 'write_<param>'
without a defined parameter is simplified. We do not check
anymore method names from base classes. Base classes
inheriting from HasAccessible are checked anyway at the
place they are defined.
+ add a test for it
+ move some tests to a new file test_all_modules.py, as
test_modules.py is getting too long
+ fix missing doc string (frappy.simulation.SimDrivable.stop)
Change-Id: Id8a9afe5c977ae3b1371bd40c6da52be2fc79eb9
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35503
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
This is meant to replace change 33375.
Optional commands and parameters may be declared with the argument
optional=True. In principle, optional commands are not really needed
to be declared, but doing so is nice for documentation reasons
and for inherited accessible properties.
Optional parameters and commands can not be used and are not
exported als long as they are not overridden in subclasses.
- add a test for this
+ fix an issue with checking for methods like read_<param> without
<param> being a parameter
Change-Id: Ide5021127a02778e7f2f7162555ec8826f1471cb
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35495
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Add a new custom module property 'original_id' indicating
the equipment_id the modules originally belongs to.
This property is only given, when distinct from the equipment_id
of the SEC node.
It happens when multiple config files are given, for all modules
but the ones given in the first file, and for routed modules,
when multiple nodes are routed or own modules are given.
+ fix an issue in router: additional modules were ignore in case
of a single node.
+ small cosmetic changes in config.py reducing IDE complains
Change-Id: If846c47a06158629cef807d22b91f69e4f416563
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35396
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
the bare value must be converted to a updated property.
add also a test for this
Change-Id: I261daaaa8e12d7f739d8b2e8389c1b871b26c5b3
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34985
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
No reason to keep stringly-typed data on that level
Change-Id: Iba8d88301bf36ef6051031d1916d1bac84ede546
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34893
Reviewed-by: Georg Brandl <g.brandl@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
implement RFC-005
- server broadcasts once on startup and answers to broadcasts
- small tool for listening on the port and sending broadcasts
Change-Id: I02d1184d6be62bef6f964eb9d238220aef062e94
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34851
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Georg Brandl <g.brandl@fz-juelich.de>
- predefined parameters/commands appear first, in the order
defined in frappy.params.PREDEFINED_ACCESSIBLES
- other (custom) parameters by inheritance order
- remove paramOrder attribute (not used currently)
Change-Id: If4c43189e4837dba057dc0a430ac6c3d1ae10829
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34904
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
check from_string and to_string are counterparts
redesign standard value checks for this
Change-Id: I825cdba5955596096fd11ab52de571f05845d7ae
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34737
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- switch to pathlib
- represent multiple confdirs as list of Paths internally, not string
with pathsep
Change-Id: I1418e561641e27cd904af0762be056cd66ee1919
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34464
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
installing a custom logger was not possible, since the RemoteLogHandler
was not installed.
Additionally, search for the RemoteLogHandler recursively upwards, since
not all loggers copy their Hanlders to their children.
Change-Id: If3e19966d9289cacd926648582e9718b7eab279c
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34288
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
- fix inheritance of command description
- when no stop method is given, then the description should indicate
that stop is a no-op -> add missing doc strings to stop methods
- add test to make sure stop command doc strings are given
when implemented
Change-Id: If891359350e8dcdec39a706841d61d4f8ec8926f
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/33266
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
on Module, use one single callback list 'paramsCallback' instead of
'valueCallbacks', 'errorCallbacks'. Redesign the mechanism to
avoid most of the closures.
Change-Id: Ie7f68f6bf97ab3f3cd961faa20b0e77730e5b37d
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/33118
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
for the use case where a parameter is a selection of discrete
float parameters
declaring a parameter as FloatEnumParam will create effectively
two parameters, one with datatype FloatRange and another with
datatype Enum, influencing each other automatically.
in a later change StructParam should be moved from
frappy/structparam.py to frappy/extparams.py
Change-Id: Ica3fd8dcaf6e9439e8178390f220dec15e52cc86
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32975
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Transported values in a change must be converted first.
As this is only relevant for the exotic "scaled" and "blob"
datatypes, this was not detected yet.
- add tests
- suppress warning PytestUnhandledThreadExceptionWarning in tests
+ change import_value methods to raise no other exceptions than
WrongTypeError and RangeError
+ simplify Command.do: as import_value already raises the
appropriate error, no more try/except is needed
Change-Id: I299e511468dc0fcecff4c20cf8a917da38b70786
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32743
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
more descriptive error when trying to export OrType, NoneOr, ValueType
and DataTypeType
Change-Id: If13815e9d2b177042b24a1bb62b1ad1d1d88b502
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32737
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
* check argument of do
* automatically set optional struct members from function signature
Change-Id: I95684f1826c1318ea92fad2bd4c9681d85ea72f5
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32501
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
- StringIO.writeline sends a command and does not expect a reply
- StringIO.multicomm and BytesIO.multicomm is improved in order
to insert individual delays in between lines and individual
noreply flags
+ fix a bug in tutorial_t_control
+ improve readability of frappy.lib.classdoc.indent_description
Change-Id: I9dea113e19147684ec41aca5267a79816bbf202c
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32267
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Split module handling code from the dispatcher.
The new class for managing Modules is called SecNode.
* change logging to no longer need a reference to modobj
* modules get a reference to the secnode obj instead of the
dispatcher
* intermediate usage fixes for frappy_psi/sea
Change-Id: Ifee4bb47aa7a4508bb4a47c9a5873b7e2d5faf67
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32249
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
in the previous version FloatRange(max=100) was neither working
properly nor complaining, because the maxval=None default was
overriding the value for max.
possible fixes:
- raise an error when min/max used as argument (confusing for
the programmer, as it is a property)
- allow both versions minval/maxval and min/max (more code)
- use min/max and a pylint directive here (the only thing to
take care is not to use the min/max builtin in __init__)
this change uses the last option for the fix
Change-Id: Iff0e0c4d0d7b165003bdeffa67a93a1cd7f29eea
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31982
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
adds a generic solution for creating parameters with struct datatype
with their members linked to individual parameters.
main use case: ctrlpars
read_*/write_* methods are either created for the main (structed)
parameter based on the corresponding methods of the individual
parameters or the methods for the individual parameters are created
based on the methods of the main parameter
+ disable pylint use-dict-literal
Change-Id: I7f1d9fb3d3b2226b548c2999bbfebe2ba5ac285e
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31405
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
add module which scans a connection and registers new devices depending
on the answer.
* change module initialization to demand-based
* move code from server to dispatcher
- remove intermediate step in Attached __get__
TODO:
factor out dispatcher (regards to playground)
discuss factoring out of module creation code from server AND
dispatcher
Change-Id: I7af959b99a84c291c526aac067a4e2bf3cd741d4
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31470
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Georg Brandl <g.brandl@fz-juelich.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
inital reads from HW should be done in the thread started by
startModule, not in startModule itself.
- add a hook method 'initialReads' for this
+ add doc for init methods
+ fix some errors in doc
Change-Id: I914e3b7ee05050eea1ee8aff3461030adf08a461
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31374
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- in order to work properly, readonly=True in limit parameters
has to be set before creating the write_* method
- more explicit: Use e.g. target_max=Limit()
- fix an error in the loop over the base classes when creating
the check_* method
- more concise error message when a limit is violated
+ fix an error in playground when using persistent parameters
Change-Id: Ibd557b55d6c0d9a2612cda4460b16e3c70e1bc9e
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31017
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- repeated errors on poller are only once logged (per poll
function / read_* method)
- during exception handling, silent=True on a SECoP error indicates
that the error is already logged
+ fix the name of HardwareError
+ add test for consistency of SECoPErrors
+ catch socket.timeout in AsynTcp
Change-Id: I9df6c775cc19553b22a4d6e39591092adf7ff9a1
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28139
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
This valve needs 8 turns to open. As the encoder forgets
the number if turns on power cycle, a home switch is
mounte, which engages during the last turn when closing.
The final close position is determined by closing the valve
with a defined motor current/torque.
+ fix an issue in StateMachine.start: the first cycle
must be called after the new state is assigned
Change-Id: I34cd05d10d97b043f9e3126310943b74ee727382
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28030
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
When several poller threads are using the same io, the resposivity
of client requests is reduced, as every thread first finishes
its pending communication requests, before it is the turn of the
request thread. This is solved by using one common poller thread
for all modules sharing the same communicator.
+ fix an issue with overriding a property with a parameter, as
this is the case for pollperiod (cfg was applied to property
instead of overriding parameter)
+ separate setFastPoll arguments into flag and fast interval
+ fix missing announceUpdate call when read function fails
+ fix mechanism for triggering polls after an io connection
reconnected again.
Change-Id: I1115a61fae3de80d18416e61f40b52a0eebb637c
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28021
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- fix: calling state.start(<new state>) on restart must ensure
that the function <new state> is called before state.start()
returns.
- modify slighly behaviour of cleanup function
Change-Id: I483a3aefa6af4712b3cf13f62c86d4c06edd1d8d
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28020
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
revert basically the former change
"init generalConfig.defaults only in secop-server"
The problem of import order when setting generalConfig.defaults
has to be solved by not overriding already existing keys when
setting the default.
Change-Id: I82121e346607dd74146279c4241e13ab63c14096
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28011
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
using one RLock per Module
+ init generalConfig for all tests
Change-Id: I88db6cacdb4aaac2ecd56644ccd6a3e5fd2d1cf2
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28005
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>