demo: fixup Switch class
Target and value are not emitting an update event upon changing target. Change-Id: Ic01d17fd8529dc0b0a720fbc79d98c7a61fc572b Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/30645 Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de> Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch> Reviewed-by: Georg Brandl <g.brandl@fz-juelich.de>
This commit is contained in:
parent
c0704b3d4f
commit
9755040ac2
@ -35,7 +35,8 @@ from frappy.properties import Property
|
||||
|
||||
|
||||
class Parameter(SECoP_Parameter):
|
||||
test = Property('A property for testing purposes', StringType(), default='', mandatory=False, extname='test')
|
||||
test = Property('A property for testing purposes', StringType(), default='',
|
||||
mandatory=False, extname='test')
|
||||
|
||||
|
||||
PERSIST = 101
|
||||
@ -62,7 +63,8 @@ class Switch(Drivable):
|
||||
)
|
||||
|
||||
description = Property('The description of the Module', StringType(),
|
||||
default='no description', mandatory=False, extname='description')
|
||||
default='no description', mandatory=False,
|
||||
extname='description')
|
||||
|
||||
def read_value(self):
|
||||
# could ask HW
|
||||
@ -70,22 +72,14 @@ class Switch(Drivable):
|
||||
self._update()
|
||||
return self.value
|
||||
|
||||
def read_target(self):
|
||||
# could ask HW
|
||||
return self.target
|
||||
|
||||
def write_target(self, value):
|
||||
# could tell HW
|
||||
setattr(self, 'status', (self.Status.BUSY, 'switching %s' % value.name.upper()))
|
||||
self.status = (self.Status.BUSY, 'switching %s' % value.name.upper())
|
||||
# note: setting self.target to the new value is done after this....
|
||||
# note: we may also return the read-back value from the hw here
|
||||
|
||||
def read_status(self):
|
||||
self.log.info("read status")
|
||||
info = self._update()
|
||||
if self.target == self.value:
|
||||
return self.Status.IDLE, ''
|
||||
return self.Status.BUSY, info
|
||||
self._update()
|
||||
return self.status
|
||||
|
||||
def _update(self):
|
||||
started = self.parameters['target'].timestamp
|
||||
@ -95,14 +89,15 @@ class Switch(Drivable):
|
||||
if time.time() > started + self.switch_on_time:
|
||||
info = 'is switched ON'
|
||||
self.value = self.target
|
||||
self.status = self.Status.IDLE, info
|
||||
elif self.target < self.value:
|
||||
info = 'waiting for OFF'
|
||||
if time.time() > started + self.switch_off_time:
|
||||
info = 'is switched OFF'
|
||||
self.value = self.target
|
||||
self.status = self.Status.IDLE, info
|
||||
if info:
|
||||
self.log.info(info)
|
||||
return info
|
||||
|
||||
|
||||
class MagneticField(Drivable):
|
||||
|
Loading…