changes after testing
This commit is contained in:
1 parent
2e0b800d0c
commit
6b4383cffc
4 files changed
+164
-168
No files matched your search
@@ -30,19 +30,30 @@ Mod('ch1',
|
||||
io = 'io_tmon',
|
||||
channel = 1,
|
||||
switcher = 'switcher',
|
||||
calcurve = 'rx078',
|
||||
enabled = False, # disable when used as heater
|
||||
calcurve = 'rx198', #'rx262', #'rx078',
|
||||
enabled = True, # disable when used as heater
|
||||
)
|
||||
|
||||
Mod('ch3',
|
||||
'frappy_psi.lakeshore370.Sensor',
|
||||
# Mod('ch3',
|
||||
# 'frappy_psi.lakeshore370.Sensor',
|
||||
# 'tmon sample',
|
||||
# io = 'io_tmon',
|
||||
# channel = 3,
|
||||
# switcher = 'switcher',
|
||||
# calcurve = 'cx198', #'cx262', #rx078',
|
||||
# enabled = True,
|
||||
# )
|
||||
|
||||
Mod('sample',
|
||||
'frappy_psi.lakeshore370.TemperatureLoop',
|
||||
'tmon sample',
|
||||
io = 'io_tmon',
|
||||
io = 'io_treg',
|
||||
channel = 3,
|
||||
switcher = 'switcher',
|
||||
calcurve = 'rx078',
|
||||
output_module = 'htr',
|
||||
enabled = True,
|
||||
)
|
||||
calcurve = 'cx078',
|
||||
)
|
||||
|
||||
Mod('ch4',
|
||||
'frappy_psi.lakeshore370.Sensor',
|
||||
@@ -61,7 +72,7 @@ Mod('ch10',
|
||||
channel = 10,
|
||||
switcher = 'switcher',
|
||||
calcurve = 'ruoxm0',
|
||||
enabled = True,
|
||||
enabled = False,
|
||||
)
|
||||
|
||||
Mod('ch11',
|
||||
@@ -84,6 +95,13 @@ Mod('ch12',
|
||||
enabled = True,
|
||||
)
|
||||
|
||||
Mod('htr',
|
||||
'frappy_psi.lakeshore370.MainOutput',
|
||||
'htr main output',
|
||||
io = 'io_tmon',
|
||||
max_heater = Param('0W')
|
||||
)
|
||||
|
||||
|
||||
# ### temperature regulating lakeshore (treg) ###
|
||||
|
||||
|
||||
+17
-3
@@ -636,6 +636,7 @@ class SensorBase(Base, Readable):
|
||||
status = Parameter(datatype=StatusType(Readable, 'DISABLED', 'BUSY'))
|
||||
channel = Property('used channel', StringType()) # input
|
||||
enabled = Parameter('enable flag', BoolType(), readonly=False)
|
||||
filter = Parameter('no. of filter points', datatype=FloatRange(2, 64, unit='points'), readonly=False)
|
||||
curve_no = None
|
||||
STATUS_BIT_LABELS = 'invalid_reading old_reading b2 b3 t_under t_over units_zero units_overrange'.split()
|
||||
_value_error = None
|
||||
@@ -680,6 +681,18 @@ class SensorBase(Base, Readable):
|
||||
self._raw_error = raw_error
|
||||
return status, value, raw
|
||||
|
||||
def read_filter(self):
|
||||
on, settle = self.query(f'FILTER?{self.channel}', int, int)
|
||||
return settle if on else 0
|
||||
|
||||
def write_filter(self, value):
|
||||
on = 1 if value else 0
|
||||
value = max(1, value)
|
||||
on, settle, _ = self.command(f'FILTER {self.channel}', on, value, self.channel)
|
||||
if not on:
|
||||
settle = 0
|
||||
return settle
|
||||
|
||||
|
||||
class RawSensor(SensorBase):
|
||||
"""class for sensors using raw value (w/o calibration curve)"""
|
||||
@@ -711,6 +724,7 @@ class Sensor(SensorBase):
|
||||
raw = Parameter('raw', datatype=FloatRange(unit='Ohm'))
|
||||
calcurve = Parameter('calibration curve name', StringType(), readonly=False)
|
||||
curve_no = None
|
||||
intype = None
|
||||
_curve_handling = False # True when a device is present and device.curve_handling is True
|
||||
DISPLAY_UNIT = 1 # number as for DISPFLD command
|
||||
# TODO: implement alarms
|
||||
@@ -941,7 +955,7 @@ class MainOutput(Output):
|
||||
self.log.info('configure %r', control_loop)
|
||||
# self.command(f'CDISP {self.output_no}', 1, self.resistance, 1, 0)
|
||||
if control_loop is None:
|
||||
mode = self.query(f'OUTMODE?{self.output_no}', int)
|
||||
mode = self.query(f'OUTMODE? {self.output_no}', int)
|
||||
if mode != 3: # open loop
|
||||
self.command(f'OUTMODE {self.output_no}', 3) # control off
|
||||
# self.command(f'OUTMODE {self.output_no}', 3, self.channel, 0) # control off
|
||||
@@ -953,10 +967,10 @@ class MainOutput(Output):
|
||||
self.put_manual_power(control_loop.power_offset)
|
||||
|
||||
def read_max_power(self):
|
||||
curidx, self._user_current = self.query(f'HTRSET? {self.output_no}', int, int, float)[1:3] # ! cmd not found in ls370 manual (HTRRNG?)
|
||||
curidx, self._user_current = self.query(f'HTRSET? {self.output_no}', int, int, float)[1:3]
|
||||
if not self._user_current:
|
||||
self._user_current = 2.0 ** (curidx * 0.5 - 1)
|
||||
self._htr_range = self.query(f'RANGE?{self.output_no}', int) or self._htr_range # ! cmd not found in ls370 manual (HTRRNG?)
|
||||
self._htr_range = self.query(f'RANGE?{self.output_no}', int) or self._htr_range
|
||||
self._power_scale = self.imax ** 2 * self.heater_ranges[self._htr_range] / 1e4
|
||||
return self.calc_power(100)
|
||||
|
||||
|
||||
+20
-26
@@ -20,7 +20,7 @@
|
||||
"""LakeShore 370"""
|
||||
|
||||
import time
|
||||
from math import sqrt
|
||||
import math
|
||||
from frappy.datatypes import BoolType, EnumType, FloatRange, IntRange, StatusType
|
||||
from frappy.core import Done, Drivable, Parameter, Property, CommonReadHandler, CommonWriteHandler, Writable, \
|
||||
IDLE, ERROR, DISABLED, Command, Attached
|
||||
@@ -422,7 +422,7 @@ class Sensor(SensorBase, ls.Sensor):
|
||||
def install_curve(self):
|
||||
"""already done in install_sensor()"""
|
||||
reply = self.query(f'INSET?{self.channel}', int, int, int, int, int)
|
||||
self.log.warn('install curve %r %r %r', reply, self.curve_no, self.enabled)
|
||||
self.log.info('install curve %r %r', self.curve_no, self.enabled)
|
||||
if reply[3] != self.curve_no:
|
||||
self.enabled, self.dwell, self.pause, _, _ = self.command(
|
||||
f'INSET {self.channel}', self.enabled, self.dwell, self.pause,
|
||||
@@ -454,7 +454,7 @@ class SorbHeater(ls.HasLscIO, Writable):
|
||||
fullpower = Parameter('power at 100 %', FloatRange(0, unit='$'), readonly=False, default=5)
|
||||
|
||||
def write_target(self, value):
|
||||
percent = 100 * sqrt(value / self.fullpower)
|
||||
percent = 100 * math.sqrt(value / self.fullpower)
|
||||
on = bool(value)
|
||||
if on != bool(self.heater_range):
|
||||
self.write_heater_range(on)
|
||||
@@ -521,31 +521,23 @@ class TemperatureLoop(ls.Loop, Sensor, Drivable):
|
||||
return target
|
||||
|
||||
|
||||
HEATER_RANGES = {8 - i: 10 ** -i for i in range(8)}
|
||||
|
||||
|
||||
class MainOutput(ls.MainOutput):
|
||||
ioClass = IO
|
||||
model = 370
|
||||
output_no = Parameter('output number', datatype=IntRange(0))
|
||||
HTRRNG = {n: i for i, n in enumerate(['off', '31.6uA', '100uA', '316uA', '1mA', '3.16mA', '10mA', '31.6mA', '100mA'])}
|
||||
# htrrng = Parameter('', EnumType(HTRRNG), readonly=False)
|
||||
htr = Parameter('heater percentage', FloatRange(unit='%'))
|
||||
minheater = Parameter('minimal heater current', FloatRange(0, 0.01, unit='A'), readonly=False, default=0)
|
||||
resistance = Parameter(datatype=FloatRange(1,100000, unit='Ohm'))
|
||||
heater_ranges = HEATER_RANGES
|
||||
heater_ranges = {8 - i: 10 ** -i for i in range(8)}
|
||||
sorted_factors = sorted((v, i) for i, v in heater_ranges.items())
|
||||
HTRST_MAP = {
|
||||
0: (IDLE, ''),
|
||||
1: (ERROR, 'Open heater load'),
|
||||
}
|
||||
_manual_output = 0.0 # TODO: check how to set this
|
||||
vmax = 50
|
||||
imax = 2
|
||||
max_currents = {4 - i: 2 ** (1 - i) for i in range(4)}
|
||||
SETPOINTLIMS = 1500.0
|
||||
sorted_factors = sorted([(fhtr * fcur ** 2, (i, h))
|
||||
for i, fcur in max_currents.items()
|
||||
for h, fhtr in HEATER_RANGES.items()
|
||||
])
|
||||
vmax = 10
|
||||
imax = 0.1
|
||||
|
||||
def get_status(self):
|
||||
st = self.query(f'HTRST?', int)
|
||||
@@ -555,21 +547,23 @@ class MainOutput(ls.MainOutput):
|
||||
if self._desired_max_power is None:
|
||||
self.log.info(f'max_heater {self.writeDict} {self.max_heater}')
|
||||
self.write_max_heater(self.max_heater)
|
||||
icurrent, htr_range = self.get_best_power_idx(self._desired_max_power, 1.1)
|
||||
self._power_scale = self.max_currents[icurrent] ** 2 * self.heater_ranges[htr_range] / 1e4
|
||||
self._htr_range = htr_range
|
||||
|
||||
self._htr_range = irng = self.get_best_power_idx(self._desired_max_power)
|
||||
self.log.info('htr rng %r', self.heater_ranges)
|
||||
user_current = max(0.1, min(self.imax, 2 * math.sqrt(self._desired_max_power /
|
||||
self.heater_ranges[irng] / self.resistance)))
|
||||
self._power_scale = user_current ** 2 * self.heater_ranges[irng] / 1e4
|
||||
control_loop = self.get_control_loop()
|
||||
ch, filt, unit, delay, curr, _, _ = self.query(f'CSET?', int, int, int, int, float, float, float) # control on
|
||||
if control_loop is None:
|
||||
mode = self.query(f'CMODE?', int)
|
||||
if mode != 3: # open loop
|
||||
self.command(f'CSET', '0', 1, 1, 1, 1, self._htr_range, self.resistance) # control off
|
||||
self.command(f'CSET', ch, filt, unit, delay, curr, self._htr_range, self.resistance)
|
||||
self.command(f'CMODE', 3) # open loop
|
||||
self.command('HTRRNG', self._htr_range)
|
||||
self.put_manual_power(self._manual_output)
|
||||
self.put_manual_power(0) # for security, we don't want to increase the output power
|
||||
else:
|
||||
self.log.info('control_loop %r, %r', control_loop, control_loop.channel)
|
||||
self.command(f'CSET', control_loop.channel, 1, 1, 1, 1, self._htr_range, self.resistance) # control on
|
||||
self.command(f'CSET', control_loop.channel, filt, unit, delay, curr, self._htr_range, self.resistance)
|
||||
self.command(f'CMODE', 1) # pid
|
||||
self.command('HTRRNG', self._htr_range)
|
||||
self.put_manual_power(control_loop.power_offset)
|
||||
@@ -622,10 +616,9 @@ class MainOutput(ls.MainOutput):
|
||||
|
||||
|
||||
class AnalogOutput(ls.HasLscIO, Writable):
|
||||
|
||||
target = Parameter('target', datatype=FloatRange(0, 100, unit='%'))
|
||||
value = Parameter('value', datatype=FloatRange(0, 100, unit='%'))
|
||||
output_no = Property('output number', datatype=IntRange(1, 2))
|
||||
output_no = Parameter('output number', datatype=IntRange(1, 2))
|
||||
|
||||
def write_target(self, target):
|
||||
if target > 0:
|
||||
@@ -634,4 +627,5 @@ class AnalogOutput(ls.HasLscIO, Writable):
|
||||
self.command(f'ANALOG {self.output_no}', 1, 0, 1, 1, 0.0, 0.0, target) # off (0)
|
||||
|
||||
def read_value(self):
|
||||
return self.query(f'ANALOG? {self.output_no}', int, int, int, int, float, float, float)[6]
|
||||
# return self.query(f'ANALOG? {self.output_no}', int, int, int, int, float, float, float)[6]
|
||||
return self.query(f'AOUT? {self.output_no}', float)
|
||||
+101
-131
@@ -52,8 +52,7 @@ class Device(ls.Device):
|
||||
channels = list(range(1, 17))
|
||||
user_curves = (21, 60) # the last curve is 20
|
||||
log_formats = True, True # log Ohm / log K is supported
|
||||
cmds_per_line = 1
|
||||
_crvsav_deadline = None
|
||||
cmds_per_line = 5
|
||||
|
||||
def disable_channel(self, channel):
|
||||
self.command(f'INSET {channel}', 0, 1, 3, 0, 1)
|
||||
@@ -99,6 +98,7 @@ class Device(ls.Device):
|
||||
if loc > 8:
|
||||
return
|
||||
self.command(f'DISPFLD {loc}', ch, sens.DISPLAY_UNIT)
|
||||
self.command('INNAME', sens.name)
|
||||
|
||||
|
||||
class Switcher(ls.HasLscIO, ChannelSwitcher):
|
||||
@@ -263,7 +263,6 @@ class SensorBase(Ls372, ls.SensorBase, Channel):
|
||||
else:
|
||||
lim = 0.2
|
||||
while rng > self.minrange and abs(raw) < lim * self.RES_SCALE[rng]:
|
||||
# self.log.info('%r < %r, %r', raw, lim * self.RES_SCALE[rng], rng)
|
||||
rng -= 1
|
||||
direction = -1
|
||||
lim -= 0.05 # not more than 4 steps at once
|
||||
@@ -298,7 +297,7 @@ class SensorBase(Ls372, ls.SensorBase, Channel):
|
||||
|
||||
@CommonReadHandler(rdgrng_params)
|
||||
def read_rdgrng(self):
|
||||
# rdgrng_params = 'range', 'iexc', 'vexc'
|
||||
# rdgrng_params = 'range', 'iexc', 'vexc' -> read_range(), read_iexc(), read_vexc()
|
||||
iscur, exc, autorange, rng, excoff, units = self.query(f'INTYPE?{self.channel}',
|
||||
int, int, int, int, int, int)
|
||||
self._prev_rdgrng = iscur, exc
|
||||
@@ -321,6 +320,7 @@ class SensorBase(Ls372, ls.SensorBase, Channel):
|
||||
|
||||
@CommonWriteHandler(rdgrng_params)
|
||||
def write_rdgrng(self, change):
|
||||
# rdgrng_params = 'range', 'iexc', 'vexc' -> write_range(), write_iexc(), write_vexc()
|
||||
self.read_range() # make sure autorange is handled
|
||||
if 'vexc' in change: # in case vext is changed, do not consider iexc
|
||||
change['iexc'] = 0
|
||||
@@ -339,24 +339,23 @@ class SensorBase(Ls372, ls.SensorBase, Channel):
|
||||
if self.autorange:
|
||||
rng = max(rng, self.minrange)
|
||||
self.command(f'INTYPE {self.channel}', iscur, exc, 0, rng, excoff, 2)
|
||||
# self.log.info('write_intype %g', rng)
|
||||
self.read_range()
|
||||
|
||||
@CommonReadHandler(inset_params)
|
||||
def read_inset(self):
|
||||
# self.log.info('read_inset %r, %x', self.write_enabled, id(type(self).write_enabled))
|
||||
# inset_params = 'enabled', 'pause', 'dwell' -> read_enabled(), read_pause(), read_dwell()
|
||||
# ignore curve no and temperature coefficient
|
||||
self.enabled, self.dwell, self.pause, self.curve_no, self.tempco \
|
||||
= self.query(f'INSET?{self.channel}', int, int, int, int, int)
|
||||
|
||||
@CommonWriteHandler(inset_params)
|
||||
def write_inset(self, change):
|
||||
# inset_params = 'enabled', 'pause', 'dwell' -> write_enabled(), write_pause(), write_dwell()
|
||||
_, _, _, curve_no, tempco = self.query(f'INSET?{self.channel}', int, int, int, int, int)
|
||||
self.enabled, self.dwell, self.pause, _, _ = self.command(
|
||||
f'INSET {self.channel}', change['enabled'], change['dwell'], change['pause'],
|
||||
curve_no, tempco)
|
||||
if 'enabled' in change:
|
||||
# self.log.info('channel %r, enable %r', self.channel, change['enabled'])
|
||||
if change['enabled']:
|
||||
# switch to enabled channel
|
||||
self.switcher.write_target(self.channel)
|
||||
@@ -365,18 +364,6 @@ class SensorBase(Ls372, ls.SensorBase, Channel):
|
||||
elif self.switcher.target == self.channel:
|
||||
self.switcher.set_delays(self)
|
||||
|
||||
def read_filter(self):
|
||||
on, settle = self.query(f'FILTER?{self.channel}', int, int)
|
||||
return settle if on else 0
|
||||
|
||||
def write_filter(self, value):
|
||||
on = 1 if value else 0
|
||||
value = max(1, value)
|
||||
on, settle, _ = self.command(f'FILTER {self.channel}', on, value, self.channel)
|
||||
if not on:
|
||||
settle = 0
|
||||
return settle
|
||||
|
||||
|
||||
class RawSensor(SensorBase, ls.RawSensor):
|
||||
DISPLAY_UNIT = 2 # number as for DISPLOC command
|
||||
@@ -406,7 +393,7 @@ class Sensor(SensorBase, ls.Sensor):
|
||||
raw = self.query(f'RDGR?{ch}', float)
|
||||
value = self.query(f'RDGK?{ch}', float)
|
||||
return rdgst, raw, value
|
||||
|
||||
|
||||
def get_data(self):
|
||||
if not self.enabled:
|
||||
self.status = DISABLED, 'disabled'
|
||||
@@ -416,12 +403,14 @@ class Sensor(SensorBase, ls.Sensor):
|
||||
|
||||
def install_sensor(self):
|
||||
if self.query(f'INSET?{self.channel}', int, int, int, int, int)[4] != self.tempco:
|
||||
# we have to call write_inset() (CommonWriteHandler)
|
||||
# as self.tempco is not a Parameter
|
||||
self.write_enabled(self.enabled)
|
||||
|
||||
def install_curve(self):
|
||||
"""already done in install_sensor()"""
|
||||
reply = self.query(f'INSET?{self.channel}', int, int, int, int, int)
|
||||
self.log.warn('install curve %r %r %r', reply, self.curve_no, self.enabled)
|
||||
self.log.info('install curve %r %r', self.curve_no, self.enabled)
|
||||
if reply[3] != self.curve_no:
|
||||
self.enabled, self.dwell, self.pause, _, _ = self.command(
|
||||
f'INSET {self.channel}', self.enabled, self.dwell, self.pause,
|
||||
@@ -437,12 +426,45 @@ class Sensor(SensorBase, ls.Sensor):
|
||||
else:
|
||||
self.tempco = 1 # NTC
|
||||
return logformat, range_limit
|
||||
|
||||
|
||||
def announce_data(self, raw, value):
|
||||
self.announceUpdate('value', value, self._value_error)
|
||||
self.announceUpdate('raw', raw, self._raw_error)
|
||||
|
||||
|
||||
class SensorA(ls.Sensor):
|
||||
channel = 'A'
|
||||
status = Parameter(datatype=StatusType(Drivable, 'DISABLED'))
|
||||
enabled = Parameter('is this channel enabled?', datatype=BoolType(), readonly=False)
|
||||
filter = Parameter('filter time', datatype=FloatRange(0, 200, unit='s'), readonly=False)
|
||||
tempco = None
|
||||
|
||||
install_sensor = Sensor.install_sensor
|
||||
get_curve_type = Sensor.get_curve_type
|
||||
announce_data = Sensor.announce_data
|
||||
|
||||
def get_internal_data(self):
|
||||
ch = self.channel
|
||||
rdgst = self.query(f'RDGST?{ch}', int)
|
||||
raw = self.query(f'RDGR?{ch}', float)
|
||||
value = self.query(f'RDGK?{ch}', float)
|
||||
return rdgst, raw, value
|
||||
|
||||
def get_data(self):
|
||||
if not self.enabled:
|
||||
self.status = DISABLED, 'disabled'
|
||||
return self.status, self.value, self.raw
|
||||
|
||||
def install_curve(self):
|
||||
"""already done in install_sensor()"""
|
||||
reply = self.query(f'INSET?{self.channel}', int, int, int, int, int)
|
||||
self.log.info('install curve %r %r', self.curve_no, self.enabled)
|
||||
if reply[3] != self.curve_no:
|
||||
self.enabled, _, _, _, _ = self.command(
|
||||
f'INSET {self.channel}', self.enabled, reply[1], reply[2],
|
||||
self.curve_no, self.tempco)
|
||||
|
||||
|
||||
class SorbHeater(ls.HasLscIO, Writable):
|
||||
value = Parameter('heater output', FloatRange(0, unit='W'))
|
||||
target = Parameter('heater output', FloatRange(0, unit='$'), readonly=False, default=0)
|
||||
@@ -518,117 +540,65 @@ class TemperatureLoop(ls.Loop, Sensor, Drivable):
|
||||
return target
|
||||
|
||||
|
||||
HEATER_RANGES = {8 - i: 10 ** -i for i in range(8)}
|
||||
class MainOutput(ls.MainOutput):
|
||||
"""Sample heater"""
|
||||
|
||||
ioClass = IO
|
||||
model = 372
|
||||
output_no = Property('output number', datatype=IntRange(0))
|
||||
HTRRNG = {n: i for i, n in enumerate(['off', '31.6uA', '100uA', '316uA', '1mA', '3.16mA', '10mA', '31.6mA', '100mA'])}
|
||||
# htrrng = Parameter('', EnumType(HTRRNG), readonly=False)
|
||||
htr = Parameter('heater percentage', FloatRange(unit='%'))
|
||||
minheater = Parameter('minimal heater current', FloatRange(0, 0.01, unit='A'), readonly=False, default=0)
|
||||
resistance = Parameter(datatype=FloatRange(1,100000, unit='Ohm'))
|
||||
heater_ranges = {8 - i: 10 ** -i for i in range(8)}
|
||||
sorted_factors = sorted((v, i) for i, v in heater_ranges.items())
|
||||
HTRST_MAP = {
|
||||
0: (IDLE, ''),
|
||||
1: (ERROR, 'Open heater load'),
|
||||
2: (ERROR, 'Heater short circuit'),
|
||||
3: (ERROR, 'Voltage compliance'),
|
||||
}
|
||||
vmax = 10
|
||||
imax = 0.1
|
||||
|
||||
@Command
|
||||
def control_off(self):
|
||||
"""switch control off"""
|
||||
self._control_active = False
|
||||
self.command(f'RANGE', 0)
|
||||
self.read_control_active()
|
||||
|
||||
def set_htrrng(self):
|
||||
if self._control_active:
|
||||
newhtr = int(self.htrrng) if self._control_active else 0
|
||||
htrrng = self.query('RANGE?', int)
|
||||
if htrrng != newhtr:
|
||||
if newhtr:
|
||||
self.log.info('switched heater on %d', newhtr)
|
||||
self.command('RANGE', newhtr)
|
||||
|
||||
def put_manual_power(self, value):
|
||||
self.command(f'MOUT ', value)
|
||||
|
||||
# def write_htrrng(self, value):
|
||||
# if self._control_active:
|
||||
# self.command('RANGE', int(value))
|
||||
# return value
|
||||
|
||||
|
||||
# class MainOutput(ls.MainOutput):
|
||||
# ioClass = IO
|
||||
# model = 372
|
||||
# HTRRNG = {n: i for i, n in enumerate(['off', '31.6uA', '100uA', '316uA', '1mA', '3.16mA', '10mA', '31.6mA', '100mA'])}
|
||||
# # htrrng = Parameter('', EnumType(HTRRNG), readonly=False)
|
||||
# htr = Parameter('heater percentage', FloatRange(unit='%'))
|
||||
# minheater = Parameter('minimal heater current', FloatRange(0, 0.01, unit='A'), readonly=False, default=0)
|
||||
# resistance = Parameter(datatype=FloatRange(1,100000, unit='Ohm'))
|
||||
# heater_ranges = HEATER_RANGES
|
||||
# HTRST_MAP = {
|
||||
# 0: (IDLE, ''),
|
||||
# 1: (ERROR, 'Open heater load'),
|
||||
# }
|
||||
# _manual_output = 0.0 # TODO: check how to set this
|
||||
# vmax = 50
|
||||
# imax = 2
|
||||
# max_currents = {4 - i: 2 ** (1 - i) for i in range(4)}
|
||||
# SETPOINTLIMS = 1500.0
|
||||
# sorted_factors = sorted([(fhtr * fcur ** 2, (i, h))
|
||||
# for i, fcur in max_currents.items()
|
||||
# for h, fhtr in HEATER_RANGES.items()
|
||||
# ])
|
||||
class AnalogOutput(ls.HasLscIO, Writable):
|
||||
"""Output 1 (warm-up heater) and Output 2 (analog/still)"""
|
||||
|
||||
# def get_status(self):
|
||||
# st = self.query(f'HTRST?', int)
|
||||
# return self.HTRST_MAP[st]
|
||||
target = Parameter('target', datatype=FloatRange(0, 100, unit='%'))
|
||||
value = Parameter('value', datatype=FloatRange(0, 100, unit='%'))
|
||||
output_no = Property('output number', datatype=IntRange(1, 2))
|
||||
|
||||
# def configure(self):
|
||||
# if self._desired_max_power is None:
|
||||
# self.log.info(f'max_heater {self.writeDict} {self.max_heater}')
|
||||
# self.write_max_heater(self.max_heater)
|
||||
# icurrent, htr_range = self.get_best_power_idx(self._desired_max_power, 1.1)
|
||||
# self._power_scale = self.max_currents[icurrent] ** 2 * self.heater_ranges[htr_range] / 1e4
|
||||
# self._htr_range = htr_range
|
||||
def write_target(self, target):
|
||||
if target > 0:
|
||||
self.command(f'ANALOG {self.output_no}', 1, 2, 1, 1, 0.0, 0.0, target) # manual (2)
|
||||
return
|
||||
self.command(f'ANALOG {self.output_no}', 1, 0, 1, 1, 0.0, 0.0, target) # off (0)
|
||||
|
||||
# control_loop = self.get_control_loop()
|
||||
# if control_loop is None:
|
||||
# mode = self.query(f'CMODE?', int)
|
||||
# if mode != 3: # open loop
|
||||
# self.command(f'CSET', '0', 1, 1, 1, 1, self._htr_range, self.resistance) # control off
|
||||
# self.command(f'CMODE', 3) # open loop
|
||||
# self.command('HTRRNG', self._htr_range)
|
||||
# self.put_manual_power(self._manual_output)
|
||||
# else:
|
||||
# self.log.info('control_loop %r, %r', control_loop, control_loop.channel)
|
||||
# self.command(f'CSET', control_loop.channel, 1, 1, 1, 1, self._htr_range, self.resistance) # control on
|
||||
# self.command(f'CMODE', 1) # pid
|
||||
# self.command('HTRRNG', self._htr_range)
|
||||
# self.put_manual_power(control_loop.power_offset)
|
||||
|
||||
# def fix_heater_range(self):
|
||||
# # switch heater range on, if needed
|
||||
# irng = self.query('HTRRNG?', int)
|
||||
# if irng != self._htr_range:
|
||||
# if irng:
|
||||
# self.log.info('output range was changed manually')
|
||||
# self._htr_range = irng
|
||||
# else:
|
||||
# self.log.info('output was off - switch on again')
|
||||
# self.command('HTRRNG', self._htr_range)
|
||||
|
||||
# def read_max_power(self):
|
||||
# htr_range = self.query(f'CSET?', int, int, int, int, int, int, float)[5]
|
||||
# htr_range = self.query('HTRRNG?', int) or htr_range
|
||||
# self._htr_range = htr_range
|
||||
# self._power_scale = 0.1 ** 2 * self.heater_ranges[htr_range] / 1e4
|
||||
# return self.calc_power(100)
|
||||
|
||||
# def read_htr(self):
|
||||
# """read heater output in percent or power depending on the heater output selection"""
|
||||
# return self.query('HTR?', float)
|
||||
|
||||
# @Command
|
||||
# def control_off(self):
|
||||
# """switch control off"""
|
||||
# self._control_active = False
|
||||
# self.command(f'HTRRNG', 0)
|
||||
# self.read_control_active()
|
||||
|
||||
# def set_htrrng(self):
|
||||
# if self._control_active:
|
||||
# newhtr = int(self.htrrng) if self._control_active else 0
|
||||
# htrrng = self.query('HTRRNG?', int)
|
||||
# if htrrng != newhtr:
|
||||
# if newhtr:
|
||||
# self.log.info('switched heater on %d', newhtr)
|
||||
# self.command('HTRRNG', newhtr)
|
||||
|
||||
# def put_manual_power(self, value):
|
||||
# self.command(f'MOUT ', value)
|
||||
|
||||
# # def write_htrrng(self, value):
|
||||
# # if self._control_active:
|
||||
# # self.command('HTRRNG', int(value))
|
||||
# # return value
|
||||
|
||||
|
||||
# class AnalogOutput(ls.HasLscIO, Writable):
|
||||
|
||||
# target = Parameter('target', datatype=FloatRange(0, 100, unit='%'))
|
||||
# value = Parameter('value', datatype=FloatRange(0, 100, unit='%'))
|
||||
# output_no = Property('output number', datatype=IntRange(1, 2))
|
||||
|
||||
# def write_target(self, target):
|
||||
# if target > 0:
|
||||
# self.command(f'ANALOG {self.output_no}', 1, 2, 1, 1, 0.0, 0.0, target) # manual (2)
|
||||
# return
|
||||
# self.command(f'ANALOG {self.output_no}', 1, 0, 1, 1, 0.0, 0.0, target) # off (0)
|
||||
|
||||
# def read_value(self):
|
||||
# return self.query(f'ANALOG? {self.output_no}', int, int, int, int, float, float, float)[6]
|
||||
def read_value(self):
|
||||
return self.query(f'AOUT? {self.output_no}', float)
|
||||
Reference in new issue