# EL737 EPICS Database for streamdevice support
# Macros
# P - Prefix
# NAME - just a name, e.g. EL737
# PROTO - Stream device protocol file
# ASYN_PORT - Low level Asyn IP Port to EL737
# Send initial initialisation commands
record(bo, "$(P):$(NAME):INIT-CONF")
{
field(DESC, "Initialises the Counterbox")
field(OUT, "@$(PROTO) initialise($(P):$(NAME):) $(ASYN_PORT)")
field(PINI, "YES") # Run at init
field(DTYP, "stream")
field(FLNK, "$(P):$(NAME):INIT-BOX")
}
# As we aren't certain of the order that PINI exectutes PVs, we only set it to
# true on INIT-CONF to make sure the box is ready to receive commands, and then
# let INIT-CONF trigger the initialisation of other necessary records
record(fanout, "$(P):$(NAME):INIT-BOX")
{
field(DESC, "Rewrite PVs to Box")
field(SELM, "All")
field(LNK0, "$(P):$(NAME):MONITOR-CHANNEL_RBV PP")
field(LNK1, "$(P):$(NAME):RAW-STATUS PP")
field(LNK2, "$(P):$(NAME):THRESHOLD_RBV PP")
}
record(longout, "$(P):$(NAME):FULL-RESET")
{
field(DESC, "Reset the Counterbox")
field(OUT, "@$(PROTO) fullReset($(P):$(NAME):) $(ASYN_PORT)")
field(DTYP, "stream")
}
################################################################################
# Status Variables
record(stringin, "$(P):$(NAME):MsgTxt")
{
field(DESC, "Unexpected received response")
field(DTYP, "devCounterBoxStringError")
field(FLNK, "$(P):$(NAME):INVALID-CONFIG")
}
# We want to recognise the invalid config error message, so that we can rerun
# the init if it occurs. This should only happen after turning the box off and
# on again or running a full reset
record(scalcout, "$(P):$(NAME):INVALID-CONFIG")
{
field(DESC, "Has the counterbox been configured?")
field(CALC, "AA[0,2] == '?OF'")
field(INAA, "$(P):$(NAME):MsgTxt")
field(FLNK, "$(P):$(NAME):REINIT-CONF")
}
record(seq, "$(P):$(NAME):REINIT-CONF")
{
field(LNK1, "$(P):$(NAME):INIT-CONF PP")
field(DO1, 1)
field(SELM, "Specified")
field(SELL, "$(P):$(NAME):INVALID-CONFIG.VAL")
}
# Important! The "$(P):$(NAME):READALL" isn't configure with a SCAN. Instead,
# it must always be triggered after the value of $(P):$(NAME):RAW-STATUS is
# updated, so that it can't be the case that the status changes back from
# counting to idle, without having updated the time and count values.
record(longin, "$(P):$(NAME):RAW-STATUS")
{
field(DESC, "Raw returned status value")
field(DTYP, "stream")
field(SCAN, ".1 second")
field(INP, "@$(PROTO) readStatus($(P):$(NAME):) $(ASYN_PORT)")
field(FLNK, "$(P):$(NAME):READALL")
}
record(calc, "$(P):$(NAME):MAP-STATUS")
{
field(DESC, "Maps Raw Status to State")
field(INPA, "$(P):$(NAME):RAW-STATUS NPP")
field(INPB, "$(P):$(NAME):INVALID-CONFIG NPP")
field(INPC, "$(P):$(NAME):RAW-STATUS.UDF NPP") # should also be invalid if can't read the status
field(CALC, "(B=1||C==1)?4:A=0?0:(A=1||A=2)?1:(A=5||A=6)?2:(A=9||A=13||A=10||A=14)?3:4")
field(FLNK, "$(P):$(NAME):STATUS")
}
record(mbbi, "$(P):$(NAME):STATUS")
{
field(DESC, "Counterbox Status")
field(INP, "$(P):$(NAME):MAP-STATUS NPP")
field(ZRVL, "0")
field(ZRST, "Idle")
field(ONVL, "1")
field(ONST, "Counting")
field(TWVL, "2")
field(TWST, "Low rate")
field(THVL, "3")
field(THST, "Paused")
# 4 should never happen, if it does it means the counter box reports undocumented statusbits
field(FRVL, "4")
field(FRST, "INVALID")
}
record(longin, "$(P):$(NAME):CHANNELS")
{
field(DESC, "Total Supported Channels")
field(VAL, $(CHANNELS))
field(DISP, 1)
}
################################################################################
# Count Commands
record(ao,"$(P):$(NAME):PRESET-COUNT")
{
field(DESC, "Count until preset reached")
field(DTYP, "stream")
field(OUT, "@$(PROTO) startWithCountPreset($(P):$(NAME):) $(ASYN_PORT)")
field(VAL, 0)
field(PREC, 2)
}
record(ao,"$(P):$(NAME):PRESET-TIME")
{
field(DESC, "Count for specified time")
field(DTYP, "stream")
field(OUT, "@$(PROTO) startWithTimePreset($(P):$(NAME):) $(ASYN_PORT)")
field(VAL, 0)
field(PREC, 2)
field(EGU, "seconds")
}
record(bo,"$(P):$(NAME):PAUSE")
{
field(DESC, "Pause the current count")
field(DTYP, "stream")
field(OUT, "@$(PROTO) pauseCount($(P):$(NAME):) $(ASYN_PORT)")
field(VAL, "0")
}
record(bo,"$(P):$(NAME):CONTINUE")
{
field(DESC, "Continue with a count that was paused")
field(DTYP, "stream")
field(OUT, "@$(PROTO) continueCount($(P):$(NAME):) $(ASYN_PORT)")
field(VAL, "0")
}
record(bo, "$(P):$(NAME):STOP")
{
field(DESC, "Stop the current counting operation")
field(DTYP, "stream")
field(OUT, "@$(PROTO) stopCount($(P):$(NAME):) $(ASYN_PORT)")
}
# TODO should changing the monitor also set things?
# or only when actually setting a threshold?
record(longout,"$(P):$(NAME):THRESHOLD")
{
field(DESC, "Minimum rate for counting to proceed")
field(VAL, "0") # Rate
field(DRVL, "0") # Minimum Rate
field(DTYP, "stream")
field(OUT, "@$(PROTO) setMinRate($(P):$(NAME):) $(ASYN_PORT)")
}
record(longin,"$(P):$(NAME):THRESHOLD_RBV")
{
field(DESC, "Minimum rate for counting to proceed")
field(DTYP, "stream")
field(INP, "@$(PROTO) readMinRate($(P):$(NAME):) $(ASYN_PORT)")
field(SCAN, "2 second")
}
record(longout,"$(P):$(NAME):THRESHOLD-MONITOR")
{
field(DESC, "Channel monitored for minimum rate")
field(VAL, "1") # Monitor
field(DRVL, "1") # Smallest Threshold Channel
field(DRVL, "$(CHANNELS)") # Largest Threshold Channel
}
record(longin,"$(P):$(NAME):THRESHOLD-MONITOR_RBV")
{
field(DESC, "Channel monitored for minimum rate")
}
################################################################################
# Read all monitors values
record(ai, "$(P):$(NAME):READALL")
{
field(DESC, "Reads monitors and elapsed time")
field(INP, "@$(PROTO) readAll$(CHANNELS)($(P):$(NAME):) $(ASYN_PORT)")
field(DTYP, "stream")
field(FLNK, "$(P):$(NAME):MAP-STATUS")
}
record(ai,"$(P):$(NAME):ELAPSED-TIME")
{
field(DESC, "Counterbox Measured Time")
field(EGU, "seconds")
}
# Not yet sure whether we want to support this
# record(longin, "$(P):$(NAME):R1")
# {
# field(DESC, "Counterbox Rate CH1")
# field(INP, "@$(PROTO) readRate($(P):$(NAME):, 1) $(ASYN_PORT)")
# field(SCAN, ".2 second")
# field(DTYP, "stream")
# }