Files
sinqDAQ/scripts/daq_soft_proton.cmd
soederqvist_a f7d4292d68
Some checks failed
Example Action / Lint (push) Successful in 3s
Example Action / BuildAndTest (push) Failing after 10s
Software proton counter DAQ (#5)
This PR implements a software based proton counterbox implementation supporting only 1 channel, the proton current that is typically propagated over channel access.

It also changes a minor convention of how to signal low rate, but this wasn't used by the client Nicos so this shouldn't affect anything.

Reviewed-on: #5
2026-03-11 09:25:17 +01:00

9 lines
439 B
Batchfile

#var softProtonDebug 1
$(SET_SIM_MODE=#)dbLoadRecords("$(sinqDAQ_DB)sim_proton_current.db", "INSTR=$(INSTR), NAME=$(NAME)")
$(SET_SIM_MODE=#)epicsEnvSet("REMOTE_RATE_PV", "$(INSTR)$(NAME):SIM-PROTON-CURR")
dbLoadRecords("$(sinqDAQ_DB)daq_soft_proton.db", "INSTR=$(INSTR), NAME=$(NAME), REMOTE_RATE_PV=$(REMOTE_RATE_PV=MHC6:IST:2), RATE_EGU=$(RATE_EGU=cts/sec), COUNTER_EGU=$(COUNTER_EGU=cts), SCALE_FACTOR=$(SCALE_FACTOR=100)")
iocInit