Start work on sinqdaq soft proton implementation

This commit is contained in:
2026-01-07 09:44:47 +01:00
parent 4801dc3279
commit 94814b2140

186
db/daq_soft_proton.db Normal file
View File

@@ -0,0 +1,186 @@
# EPICS database for counterbox-like interface using proton current,
# as retrieved via network from HIPA.
#
# This is created to be able reuse the SinqDAQ interface
# in Nicos, to avoid having more code to maintain there.
record(mbbi, "$(INSTR)$(NAME):STATUS")
{
field(DESC, "DAQ Status")
field(ZRVL, "0")
field(ZRST, "Idle")
field(ONVL, "1")
field(ONST, "Counting")
field(TWVL, "2")
field(TWST, "Low rate")
field(THVL, "3")
field(THST, "Paused")
# 4 should never happen, if it does it means the DAQ reports undocumented statusbits
field(FRVL, "4")
field(FRST, "INVALID")
}
record(longin, "$(INSTR)$(NAME):CHANNELS")
{
field(DESC, "Total Supported Channels")
field(VAL, $(CHANNELS=1))
field(DISP, 1)
}
record(longout, "$(INSTR)$(NAME):FULL-RESET")
{
field(DESC, "Reset the DAQ")
field(OUT, "@$(PROTO) fullReset($(INSTR)$(NAME):) $(ASYN_PORT)")
field(DTYP, "stream")
}
record(stringin, "$(INSTR)$(NAME):MsgTxt")
{
field(DESC, "Miscellanous messages")
}
################################################################################
# Count Commands
record(ao,"$(INSTR)$(NAME):PRESET-COUNT")
{
field(DESC, "Count until preset reached")
field(DTYP, "stream")
field(OUT, "@$(PROTO) startWithCountPreset$(CHANNELS)($(INSTR)$(NAME):) $(ASYN_PORT)")
field(VAL, 0)
field(PREC, 2)
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
}
record(ao,"$(INSTR)$(NAME):PRESET-TIME")
{
field(DESC, "Count for specified time")
field(DTYP, "stream")
field(OUT, "@$(PROTO) startWithTimePreset$(CHANNELS)($(INSTR)$(NAME):) $(ASYN_PORT)")
field(VAL, 0)
field(PREC, 2)
field(EGU, "seconds")
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
}
record(bo,"$(INSTR)$(NAME):PAUSE")
{
field(DESC, "Pause the current count")
field(DTYP, "stream")
field(OUT, "@$(PROTO) pauseCount($(INSTR)$(NAME):) $(ASYN_PORT)")
field(VAL, "0")
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
}
record(bo,"$(INSTR)$(NAME):CONTINUE")
{
field(DESC, "Continue with a count that was paused")
field(DTYP, "stream")
field(OUT, "@$(PROTO) continueCount($(INSTR)$(NAME):) $(ASYN_PORT)")
field(VAL, "0")
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
}
record(longout, "$(INSTR)$(NAME):STOP")
{
field(DESC, "Stop the current counting operation")
field(DTYP, "stream")
field(OUT, "@$(PROTO) stopCount($(INSTR)$(NAME):) $(ASYN_PORT)")
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
}
record(longout,"$(INSTR)$(NAME):THRESHOLD-MONITOR")
{
# Alias to RBV to be compatible with higher level interface
alias("$(INSTR)$(NAME):THRESHOLD-MONITOR_RBV")
field(DESC, "Channel monitored for minimum rate")
field(VAL, "1") # Monitor
field(DRVL, "0") # Smallest Threshold Channel (0 is off)
field(DRVH, "$(CHANNELS=1)") # Largest Threshold Channel
field(DTYP, "stream")
}
record(ao,"$(INSTR)$(NAME):THRESHOLD")
{
# Alias to RBV to be compatible with higher level interface
alias("$(INSTR)$(NAME):THRESHOLD_RBV")
field(DESC, "Minimum rate for counting to proceed")
field(VAL, "1") # Default Rate
# Could perhaps still be improved.
# It seems to only accept whole counts?
field(DRVL, "1") # Minimum Rate
field(DRVH, "100000") # Maximum Rate
field(OMSL, "supervisory")
field(OROC, "0")
}
record(ai,"$(INSTR)$(NAME):ELAPSED-TIME")
{
field(DESC, "DAQ Measured Time")
field(EGU, "sec")
field(FLNK, "$(INSTR)$(NAME):ETO")
}
# Subroutine record which emulates the counterbox functionality
record(sub, "$(INSTR)$(NAME):EMULATION")
{
field(SCAN, "0.1 seconds"
field(INAM, "InitEmulatedCounter")
field(SNAM, "ProcessEmulatedCounter"
field(INPA, "$(INSTR)$(NAME):STATUS")
field(INPB, "$(INSTR)$(NAME):M$(CHANNEL=0)")
field(INPC, "$(INSTR)$(NAME):ELAPSED-TIME")
field(INPD, "$(INSTR)$(NAME):R$(CHANNEL=0) PP")
field(INPE, "$(INSTR)$(NAME):PRESET-COUNT")
field(INPF, "$(INSTR)$(NAME):PRESET-TIME")
field(INPG, "$(INSTR)$(NAME):PAUSE")
field(INPH, "$(INSTR)$(NAME):CONTINUE")
field(INPI, "$(INSTR)$(NAME):STOP")
field(OUTA, "$(INSTR)$(NAME):STATUS PP")
field(OUTB, "$(INSTR)$(NAME):M$(CHANNEL=0) PP")
field(OUTC, "$(INSTR)$(NAME):ELAPSED-TIME PP")
}
#######################
# Channel interface
#######################
record(int64in, "$(INSTR)$(NAME):M$(CHANNEL=0)")
{
field(DESC, "DAQ CH$(CHANNEL=0)")
field(EGU, "cts")
}
record(calc, "$(INSTR)$(NAME):R$(CHANNEL=0)")
{
field(DESC, "Rate of DAQ CH$(CHANNEL=0)")
field(INPA, "$(REMOTE_RATE_PV) CA"
field(INPB, "$(SHUTTER1_PV=0)")
field(INPC, "$(SHUTTER1_CLOSED_VAL=1)"
field(INPD, "$(SHUTTER2_PV=0)")
field(INPE, "$(SHUTTER2_CLOSED_VAL=1)")
# If either shutter is closed we have no rate
field(CALC, "B != C && D != E ? A : 0")
field(EGU, "cts/sec")
}
# Clear channel, has to be calcout due to client
# writing 1 to it.
record(calcout, "$(INSTR)$(NAME):C$(CHANNEL=0)")
{
field(DESC, "Clear the current channel count")
field(OOPT, "Every Time")
field(DOPT, "Use OCAL")
field(OCAL, "0")
field(OUT, "$(INSTR)$(NAME):M$(CHANNEL=0) PP"
}
# Current Status of Channel, i.e. is it ready to count?
# This is probbably only need to satify the interface.
record(bi, "$(INSTR)$(NAME):S$(CHANNEL=0)")
{
field(DESC, "Channel Status")
field(VAL, 0)
field(ZNAM, "OK")
field(ONAM, "CLEARING")
}