@ -0,0 +1,212 @@
|
||||
# EPICS Database for streamdevice support with SinqDAQ Systems
|
||||
#
|
||||
# Macros
|
||||
# INSTR - Prefix
|
||||
# NAME - the device name, e.g. EL737
|
||||
# PROTO - Stream device protocol file
|
||||
# ASYN_PORT - Low level Asyn IP Port to EL737
|
||||
|
||||
# Send initial initialisation commands
|
||||
record(bo, "$(INSTR)$(NAME):INIT-CONF")
|
||||
{
|
||||
field(DESC, "Initialises the DAQ")
|
||||
field(OUT, "@$(PROTO) initialise($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(PINI, "YES") # Run at init
|
||||
field(DTYP, "stream")
|
||||
}
|
||||
|
||||
record(longout, "$(INSTR)$(NAME):FULL-RESET")
|
||||
{
|
||||
field(DESC, "Reset the DAQ")
|
||||
field(OUT, "@$(PROTO) fullReset($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(DTYP, "stream")
|
||||
}
|
||||
|
||||
################################################################################
|
||||
# Status Variables
|
||||
|
||||
record(stringin, "$(INSTR)$(NAME):MsgTxt")
|
||||
{
|
||||
field(DESC, "Unexpected received response")
|
||||
field(DTYP, "devDAQStringError")
|
||||
field(FLNK, "$(INSTR)$(NAME):INVALID-CONFIG")
|
||||
}
|
||||
|
||||
# We want to recognise the invalid config error message, so that we can rerun
|
||||
# the init if it occurs. This should only happen after turning the DAQ off and
|
||||
# on again or running a full reset
|
||||
record(scalcout, "$(INSTR)$(NAME):INVALID-CONFIG")
|
||||
{
|
||||
field(DESC, "Has the DAQ been configured?")
|
||||
field(CALC, "AA[0,2] == '?OF'")
|
||||
field(INAA, "$(INSTR)$(NAME):MsgTxt")
|
||||
field(FLNK, "$(INSTR)$(NAME):REINIT-CONF")
|
||||
}
|
||||
|
||||
record(seq, "$(INSTR)$(NAME):REINIT-CONF")
|
||||
{
|
||||
field(LNK1, "$(INSTR)$(NAME):INIT-CONF PP")
|
||||
field(DO1, 1)
|
||||
field(SELM, "Specified")
|
||||
field(SELL, "$(INSTR)$(NAME):INVALID-CONFIG.VAL")
|
||||
}
|
||||
|
||||
# Important! The "$(INSTR)$(NAME):READALL" isn't configure with a SCAN. Instead,
|
||||
# it must always be triggered after the value of $(INSTR)$(NAME):RAW-STATUS is
|
||||
# updated, so that it can't be the case that the status changes back from
|
||||
# counting to idle, without having updated the time and count values.
|
||||
record(longin, "$(INSTR)$(NAME):RAW-STATUS")
|
||||
{
|
||||
field(DESC, "Raw returned status value")
|
||||
field(DTYP, "stream")
|
||||
field(SCAN, ".5 second")
|
||||
field(INP, "@$(PROTO) readStatus($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(FLNK, "$(INSTR)$(NAME):READALL")
|
||||
}
|
||||
|
||||
record(calc, "$(INSTR)$(NAME):MAP-STATUS")
|
||||
{
|
||||
field(DESC, "Maps Raw Status to State")
|
||||
field(INPA, "$(INSTR)$(NAME):RAW-STATUS NPP")
|
||||
field(INPB, "$(INSTR)$(NAME):INVALID-CONFIG NPP")
|
||||
field(INPC, "$(INSTR)$(NAME):RAW-STATUS.UDF NPP") # should also be invalid if can't read the status
|
||||
field(CALC, "(B=1||C==1)?4:A=0?0:(A=1||A=2)?1:(A=5||A=6)?2:(A=9||A=13||A=10||A=14)?3:4")
|
||||
field(FLNK, "$(INSTR)$(NAME):STATUS")
|
||||
}
|
||||
|
||||
record(mbbi, "$(INSTR)$(NAME):STATUS")
|
||||
{
|
||||
field(DESC, "DAQ Status")
|
||||
field(INP, "$(INSTR)$(NAME):MAP-STATUS NPP")
|
||||
field(ZRVL, "0")
|
||||
field(ZRST, "Idle")
|
||||
field(ONVL, "1")
|
||||
field(ONST, "Counting")
|
||||
field(TWVL, "2")
|
||||
field(TWST, "Low rate")
|
||||
field(THVL, "3")
|
||||
field(THST, "Paused")
|
||||
# 4 should never happen, if it does it means the DAQ reports undocumented statusbits
|
||||
field(FRVL, "4")
|
||||
field(FRST, "INVALID")
|
||||
}
|
||||
|
||||
record(longin, "$(INSTR)$(NAME):CHANNELS")
|
||||
{
|
||||
field(DESC, "Total Supported Channels")
|
||||
field(VAL, $(CHANNELS))
|
||||
field(DISP, 1)
|
||||
}
|
||||
|
||||
|
||||
################################################################################
|
||||
# Count Commands
|
||||
|
||||
record(ao,"$(INSTR)$(NAME):PRESET-COUNT")
|
||||
{
|
||||
field(DESC, "Count until preset reached")
|
||||
field(DTYP, "stream")
|
||||
field(OUT, "@$(PROTO) startWithCountPreset$(CHANNELS)($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(VAL, 0)
|
||||
field(PREC, 2)
|
||||
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
|
||||
}
|
||||
|
||||
record(ao,"$(INSTR)$(NAME):PRESET-TIME")
|
||||
{
|
||||
field(DESC, "Count for specified time")
|
||||
field(DTYP, "stream")
|
||||
field(OUT, "@$(PROTO) startWithTimePreset$(CHANNELS)($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(VAL, 0)
|
||||
field(PREC, 2)
|
||||
field(EGU, "seconds")
|
||||
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
|
||||
}
|
||||
|
||||
record(bo,"$(INSTR)$(NAME):PAUSE")
|
||||
{
|
||||
field(DESC, "Pause the current count")
|
||||
field(DTYP, "stream")
|
||||
field(OUT, "@$(PROTO) pauseCount($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(VAL, "0")
|
||||
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
|
||||
}
|
||||
|
||||
record(bo,"$(INSTR)$(NAME):CONTINUE")
|
||||
{
|
||||
field(DESC, "Continue with a count that was paused")
|
||||
field(DTYP, "stream")
|
||||
field(OUT, "@$(PROTO) continueCount($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(VAL, "0")
|
||||
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
|
||||
}
|
||||
|
||||
record(bo, "$(INSTR)$(NAME):STOP")
|
||||
{
|
||||
field(DESC, "Stop the current counting operation")
|
||||
field(DTYP, "stream")
|
||||
field(OUT, "@$(PROTO) stopCount($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(FLNK, "$(INSTR)$(NAME):RAW-STATUS")
|
||||
}
|
||||
|
||||
record(ao,"$(INSTR)$(NAME):THRESHOLD")
|
||||
{
|
||||
field(DESC, "Minimum rate for counting to proceed")
|
||||
field(VAL, "0") # Rate
|
||||
field(DRVL, "0.000001") # Minimum Rate
|
||||
field(DRVH, "100000") # Maximum Rate
|
||||
field(OMSL, "supervisory")
|
||||
field(OROC, "0")
|
||||
field(OUT, "@$(PROTO) setMinRate($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(DTYP, "stream")
|
||||
}
|
||||
|
||||
record(ai,"$(INSTR)$(NAME):THRESHOLD_RBV")
|
||||
{
|
||||
field(DESC, "Minimum rate for counting to proceed")
|
||||
field(INP, "@$(PROTO) readMinRate($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(DTYP, "stream")
|
||||
field(SCAN, "1 second")
|
||||
}
|
||||
|
||||
record(longout,"$(INSTR)$(NAME):THRESHOLD-MONITOR")
|
||||
{
|
||||
field(DESC, "Channel monitored for minimum rate")
|
||||
field(VAL, "1") # Monitor
|
||||
field(DRVL, "0") # Smallest Threshold Channel (0 is off)
|
||||
field(DRVH, "$(CHANNELS)") # Largest Threshold Channel
|
||||
field(OUT, "@$(PROTO) setRateMonitor($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(DTYP, "stream")
|
||||
}
|
||||
|
||||
record(longin,"$(INSTR)$(NAME):THRESHOLD-MONITOR_RBV")
|
||||
{
|
||||
field(DESC, "Channel monitored for minimum rate")
|
||||
field(INP, "@$(PROTO) readRateMonitor($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(DTYP, "stream")
|
||||
field(SCAN, "1 second")
|
||||
}
|
||||
|
||||
record(bo, "$(INSTR)$(NAME):CT")
|
||||
{
|
||||
field(DESC, "Clear the timer")
|
||||
field(DTYP, "stream")
|
||||
field(OUT, "@$(PROTO) clearTimer($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
}
|
||||
|
||||
################################################################################
|
||||
# Read all monitors values
|
||||
|
||||
record(ai, "$(INSTR)$(NAME):READALL")
|
||||
{
|
||||
field(DESC, "Reads monitors and elapsed time")
|
||||
field(INP, "@$(PROTO) readAll$(CHANNELS)($(INSTR)$(NAME):) $(ASYN_PORT)")
|
||||
field(DTYP, "stream")
|
||||
field(FLNK, "$(INSTR)$(NAME):MAP-STATUS")
|
||||
}
|
||||
|
||||
record(ai,"$(INSTR)$(NAME):ELAPSED-TIME")
|
||||
{
|
||||
field(DESC, "DAQ Measured Time")
|
||||
field(EGU, "seconds")
|
||||
}
|
Reference in New Issue