# The is the "ASYN" example for communication to either a Newport MM4000/5 or an
# IMS483 controller. The examples must be configured by including or omitting
# comment characters (i.e., #'s) from this file.
# "#!" marks lines that can be uncommented.
# The following must be added for many board support packages
#!cd "... IOC st.cmd complete directory path ... "
< cdCommands
#!< ../nfsCommands
cd topbin
# If the VxWorks kernel was built using the project facility, the following must
# be added before any C++ code is loaded (see SPR #28980).
sysCplusEnable=1
ld < WithMPFVx.munch
cd startup
dbLoadDatabase("$(TOP)/dbd/WithMPFVx.dbd")
WithMPFVx_registerRecordDeviceDriver(pdbbase)
dbLoadRecords("$(TOP)/db/WithMPF.db")
# Configure the ASYN server code. This MUST be configured too!
< st_asynserver.cmd.Vx
# Newport MM4000 driver setup parameters:
# (1) maximum number of controllers in system
# (2) motor task polling rate (min=1Hz,max=60Hz)
#!MM4000Setup(1, 10)
# Newport MM4000 driver configuration parameters:
# (1) controller# being configured
# (2) ASYN port name
# (3) address (GPIB only)
#!MM4000Config(0, "a-Serial[0]")
#!drvMM4000debug=4
# Newport PM500 driver setup parameters:
# (1) maximum number of controllers in system
# (2) motor task polling rate (min=1Hz,max=60Hz)
#!PM500Setup(1, 10)
# Newport PM500 configuration parameters:
# (1) controller# being configured,
# (2) ASYN port name
# (3) address (GPIB only)
#!PM500Config(0, "a-Serial[0]")
#!drvPM500debug=4
# IMS IM483 driver setup parameters:
# (1) maximum number of controllers in system
# (2) motor task polling rate (min=1Hz,max=60Hz)
# SM - single mode PL - party mode
#!IM483SMSetup(1, 10)
#!IM483PLSetup(1, 10)
# IMS IM483 configuration parameters:
# (1) controller# (chain#) being configured,
# (2) ASYN port name
# SM - single mode PL - party mode
#!IM483SMConfig(0, "a-Serial[0]")
#!drvIM483SMdebug=4
#!IM483PLConfig(0, "a-Serial[0]")
#!drvIM483PLdebug=4
# MCB-4B driver setup parameters:
# (1) maximum # of controllers,
# (2) motor task polling rate (min=1Hz, max=60Hz)
#!MCB4BSetup(1, 10)
# MCB-4B driver configuration parameters:
# (1) controller
# (2) ASYN port name
#!MCB4BConfig(0, "a-Serial[0]")
#!drvMCB4BDebug=4
# Newport ESP300 driver setup parameters:
# (1) maximum number of controllers in system
# (2) motor task polling rate (min=1Hz,max=60Hz)
#!ESP300Setup(1, 10)
# Newport ESP300 driver configuration parameters:
# (1) controller# being configured,
# (2) ASYN port name
# (3) address (GPIB only)
#!ESP300Config(0, "a-Serial[0]")
#!drvESP300debug = 4
# MicroMo MVP2001 driver setup parameters:
#
# NOTE: The 1st controller on each chain should have it's address = 1.
# The rest of the controllers on a chain should follow sequentially.
#
#
# int MVP2001Setup(int num_cards, /* number of CHAINS of controllers */
# int scan_rate) /* polling rate (Min=1Hz, max=60Hz) */
#!MVP2001Setup(1, 10)
# int MVP2001Config(int card, /* CHAIN being configured */
# (2) ASYN port name
#!MVP2001Config(0, "a-Serial[0]")
#!drvMVP2001debug=4
# PI C-844 driver setup parameters:
# (1) maximum number of controllers in system
# (2) motor task polling rate (min=1Hz,max=60Hz)
#!PIC844Setup(1, 10)
# PI C-844 driver configuration parameters:
# (1) controller# being configured,
# (2) ASYN port name
# (3) address (GPIB only)
#!PIC844Config(0, "a-Serial[0]")
#!drvPIC844debug = 4
# Micos MoCo driver setup parameters:
# Load MicosSetup once.
# (1) max # of controller groups. Controller groups are per serial
# port.
# (2) max # axes per controller group. Maximum 16. (addr 0-15)
# (3) motor task polling rate (min=1Hz, max=60Hz, 10Hz works well)
# Example:
# MicosSetup(1, 2, 10) 1 group. 2 axes (controllers) in the group.
# 10Hz poll.
#!MicosSetup(1, 2, 10)
# Micos MoCo driver configuration parameters:
# Load one MicosConfig for each group of Micos drivers.
# (1) "Controller group" number
# (2) ASYN port name
#!MicosConfig(0, "a-Serial[0]")
#!drvMicosDebug = 4
# IMS MDrive driver setup parameters:
# (1) maximum number of controllers in system
# (2) motor task polling rate (min=1Hz,max=60Hz)
#!MDriveSetup(1, 10)
# IMS MDrive driver configuration parameters:
# (1) controller# being configured,
#!MDriveConfig(0, "a-Serial[0]")
#!drvMDrivedebug = 4
iocInit