Proton local user 292032fca2 Major modifications to account for introducing in the calibration paramters the panel center offset:
This include as most important changes:
- itkImageProcessor UpdateProjectionGeometryMeta - SetOriginLPS now includes that offset
- ui_qvtk_handler: change in overlapping of two images. This now use the vtk provided image center which also consider image orientation and allows us to work under no assumption of center at same position between DRT and TOPO
This release was tested on Imaging calibration data. Consistency was good. On Phantom data also good consistency on Correction Vector between SHORT and LONG