eiger server: more checks for feb interface reg readouts

This commit is contained in:
maliakal_d 2020-08-31 18:22:16 +02:00
parent 973b8f7106
commit adb6171e35

View File

@ -1892,7 +1892,7 @@ int Feb_Control_GetRightFPGATemp() {
}
unsigned int temperature = 0;
if (!Feb_Interface_ReadRegister(Feb_Control_rightAddress, FEB_REG_STATUS,
&temperature) {
&temperature)) {
LOG(logERROR, ("Trouble reading FEB_REG_STATUS reg to get right feb "
"temperature\n"));
return 0;
@ -1911,7 +1911,7 @@ int64_t Feb_Control_GetMeasuredPeriod() {
}
unsigned int value = 0;
if (!Feb_Interface_ReadRegister(Feb_Control_leftAddress, MEAS_PERIOD_REG,
&value) {
&value)) {
LOG(logERROR,
("Trouble reading MEAS_PERIOD_REG reg to get measured period\n"));
return 0;
@ -1925,7 +1925,7 @@ int64_t Feb_Control_GetSubMeasuredPeriod() {
}
unsigned int value = 0;
if (!Feb_Interface_ReadRegister(Feb_Control_leftAddress, MEAS_SUBPERIOD_REG,
&value) {
&value)) {
LOG(logERROR, ("Trouble reading MEAS_SUBPERIOD_REG reg to get measured "
"sub period\n"));
return 0;