mirror of
https://github.com/slsdetectorgroup/slsDetectorPackage.git
synced 2025-06-24 02:27:59 +02:00
mythen3: fix of external signals to not allow master output inversion, but can edge detect not configurable, and default dout pulse length
This commit is contained in:
@ -923,9 +923,11 @@ class Detector {
|
||||
|
||||
/** [Gotthard] signal index is 0
|
||||
* Options: TRIGGER_IN_RISING_EDGE, TRIGGER_IN_FALLING_EDGE
|
||||
* [Mythen3] signal index 0-3 for master input, 4-7 master output signals
|
||||
* Options: TRIGGER_IN_RISING_EDGE, TRIGGER_IN_FALLING_EDGE (for master
|
||||
* input trigger only), INVERSION_ON, INVERSION_OFF */
|
||||
* [Mythen3] signal index 0 is master input trigger signal, 1-3 for master
|
||||
* input gate signals, 4 is busy out signal, 5-7 is master output gate
|
||||
* signals.
|
||||
* Options: TRIGGER_IN_RISING_EDGE, TRIGGER_IN_FALLING_EDGE (for
|
||||
* master input trigger only), INVERSION_ON, INVERSION_OFF */
|
||||
void setExternalSignalFlags(int signalIndex, defs::externalSignalFlag value,
|
||||
Positions pos = {});
|
||||
|
||||
|
@ -766,8 +766,9 @@ std::string CmdProxy::ExternalSignal(int action) {
|
||||
"[trigger_in_rising_edge|trigger_in_falling_edge]"
|
||||
"\n\t[Mythen3] [0-7] "
|
||||
"[trigger_in_rising_edge|trigger_in_falling_edge|inversion_on|"
|
||||
"inversion_off]\n\t where 0-3 is master input signals and 4-7 is "
|
||||
"master output signals"
|
||||
"inversion_off]\n\t where 0 is master input trigger signal, 1-3 "
|
||||
"is master input gate signals, 4 is busy out signal and 5-7 is "
|
||||
"master output gate signals"
|
||||
<< '\n';
|
||||
} else if (action == defs::GET_ACTION) {
|
||||
if (args.size() != 1) {
|
||||
|
Reference in New Issue