feat: add nexus format
CI for xtreme_bec / test (push) Failing after 30s

This commit is contained in:
wakonig_k committed 2026-08-18 14:12:29 +02:00
1 parent 509ca6a195
commit b16cdcdf51
1 file changed
+233
+233
View File
@@ -0,0 +1,233 @@
from __future__ import annotations
from bec_server.file_writer.default_writer import DefaultFormat
class XtremeNeXusFormat(DefaultFormat):
"""NeXus layout for the X-Treme beamline device configuration."""
_MIRROR_GROUPS = {
"cmu": ("collimating_mirror", "Collimating mirror", 16.3),
"fmu": ("focusing_mirror", "Focusing mirror", 22.3),
"rmu": ("refocusing_mirror", "Refocusing mirror", 29.8),
}
_MIRROR_AXES = ("y", "z", "rx", "ry", "rz")
_SLIT_SIGNALS = ("sl1xi", "sl1xo", "sl1yb", "sl1yt", "sl1xc", "sl1xs", "sl1yc", "sl1ys")
_KEITHLEY_GROUPS = (
("tey_electrometer", "Keithley 1 / 428 tey", "keithley_1"),
("i0_electrometer", "Keithley 2 / 428 i0", "keithley_2"),
("diode_electrometer", "Keithley 3 / 428 diode", "keithley_3"),
)
_MONITOR_SIGNALS = ("s1", "s2", "s3", "s4", "s5", "s6", "s7")
def format(self) -> None:
entry = self.storage.create_group("entry")
self.write_entry_metadata(entry)
##############################
#### Entry Data ####
##############################
data = entry.create_group("data")
data.attrs["NX_class"] = "NXdata"
##############################
#### Sample ####
##############################
sample = entry.create_group("sample")
sample.attrs["NX_class"] = "NXsample"
sample.create_dataset(
name="name",
data=self.info_storage.get("sample_name") or self.get_entry("samplename") or "",
)
sample.create_dataset(
name="description", data=self.info_storage.get("sample_description") or ""
)
instrument = entry.create_group("instrument")
instrument.attrs["NX_class"] = "NXinstrument"
instrument.create_dataset(name="name", data="X-Treme beamline")
##############################
#### Source ####
##############################
source = instrument.create_group("source")
source.attrs["NX_class"] = "NXsource"
source.create_dataset(name="type", data="Synchrotron X-ray Source")
source.create_dataset(name="name", data="Swiss Light Source")
source.create_dataset(name="probe", data="x-ray")
self.safe_dataset(group=source, name="current", device="curr")
self.safe_dataset(group=source, name="orbit_feedback_state", device="ofb")
insertion_device = instrument.create_group("insertion_device")
insertion_device.attrs["NX_class"] = "NXinsertion_device"
insertion_device.create_dataset(name="type", data="undulator")
insertion_device.create_dataset(name="description", data="Apple II undulator")
self.safe_dataset(group=insertion_device, name="polarization", device="uind_mode")
self.safe_dataset(group=insertion_device, name="energy", device="uind_energy")
self.safe_dataset(group=insertion_device, name="gap", device="idgap")
self.safe_dataset(group=insertion_device, name="harmonic", device="uind_harmonic")
xbpm = instrument.create_group("xbpm_1")
xbpm.attrs["NX_class"] = "NXpositioner"
xbpm.create_dataset(
name="description", data="X-ray BPM1 translation stage in the front-end"
)
self.safe_dataset(group=xbpm, name="x", device="xbpm1x")
self.safe_dataset(group=xbpm, name="y", device="xbpm1y")
valve = instrument.create_group("valve")
valve.attrs["NX_class"] = "NXpositioner"
valve.create_dataset(name="description", data="Endstation vacuum valve")
self.safe_dataset(group=valve, name="value", device="valve")
shutter = instrument.create_group("shutter")
shutter.attrs["NX_class"] = "NXpositioner"
shutter.create_dataset(name="description", data="Beamline shutter")
self.safe_dataset(group=shutter, name="value", device="shutter")
##############################
#### Front End ####
##############################
front_end_slit = instrument.create_group("front_end_slit")
front_end_slit.attrs["NX_class"] = "NXslit"
front_end_slit.create_dataset(name="description", data="Front-end slit 1")
self.safe_dataset(group=front_end_slit, name="x_gap", device="sl1xs")
self.safe_dataset(group=front_end_slit, name="y_gap", device="sl1ys")
self.safe_dataset(group=front_end_slit, name="x_translation", device="sl1xc")
self.safe_dataset(group=front_end_slit, name="y_translation", device="sl1yc")
self.safe_dataset(group=front_end_slit, name="x_ring_blade", device="sl1xi")
self.safe_dataset(group=front_end_slit, name="x_wall_blade", device="sl1xo")
self.safe_dataset(group=front_end_slit, name="y_bottom_blade", device="sl1yb")
self.safe_dataset(group=front_end_slit, name="y_top_blade", device="sl1yt")
##############################
#### Optics ####
##############################
monochromator = instrument.create_group("monochromator")
monochromator.attrs["NX_class"] = "NXmonochromator"
self.safe_dataset(group=monochromator, name="energy", device="mono")
self.safe_dataset(group=monochromator, name="beamline_energy", device="energy")
self.safe_dataset(group=monochromator, name="mode", device="energy_mode")
self.safe_dataset(group=monochromator, name="cff", device="mono", signal="cff")
plane_mirror = monochromator.create_group("plane_mirror")
plane_mirror.attrs["NX_class"] = "NXmirror"
plane_mirror.create_dataset(name="description", data="Plane mirror")
plane_mirror.create_dataset(name="distance", data=21.3)
plane_mirror._storage["distance"].attrs["units"] = "m" # pylint: disable=protected-access
self.safe_dataset(group=plane_mirror, name="theta", device="mirror_theta")
grating = monochromator.create_group("grating")
grating.attrs["NX_class"] = "NXgrating"
grating.create_dataset(name="description", data="Plane grating")
grating.create_dataset(name="distance", data=21.3)
grating._storage["distance"].attrs["units"] = "m" # pylint: disable=protected-access
self.safe_dataset(group=grating, name="beta", device="grating_beta")
exit_slit = monochromator.create_group("exit_slit")
exit_slit.attrs["NX_class"] = "NXslit"
exit_slit.create_dataset(name="description", data="Vertical exit slit")
self.safe_dataset(group=exit_slit, name="y_gap", device="exit_slit")
for prefix, (group_name, description, distance_m) in self._MIRROR_GROUPS.items():
mirror = instrument.create_group(group_name)
mirror.attrs["NX_class"] = "NXmirror"
mirror.create_dataset(name="description", data=description)
mirror.create_dataset(name="distance", data=distance_m)
mirror._storage["distance"].attrs["units"] = "m" # pylint: disable=protected-access
for axis in self._MIRROR_AXES:
device_name = f"{prefix}_{axis}"
self.safe_dataset(group=mirror, name=axis, device=device_name)
##############################
#### Endstation ####
##############################
filter_group = instrument.create_group("filter")
filter_group.attrs["NX_class"] = "NXattenuator"
filter_group.create_dataset(
name="description", data="3 um-thick Al filter before the exit slit"
)
filter_group.create_dataset(name="type", data="Al")
thickness = filter_group.create_dataset(name="thickness", data=3.0)
thickness.attrs["units"] = "um"
self.safe_dataset(group=filter_group, name="position", device="filter")
gold_mesh_1 = instrument.create_group("gold_mesh_1")
gold_mesh_1.attrs["NX_class"] = "NXpositioner"
gold_mesh_1.create_dataset(name="description", data="Gold mesh 1 insertion stage")
self.safe_dataset(group=gold_mesh_1, name="value", device="goldmesh1")
gold_mesh_2 = instrument.create_group("gold_mesh_2")
gold_mesh_2.attrs["NX_class"] = "NXpositioner"
gold_mesh_2.create_dataset(name="description", data="Gold mesh 2 insertion stage")
self.safe_dataset(group=gold_mesh_2, name="value", device="goldmesh2")
end_station = instrument.create_group("end_station")
end_station.attrs["NX_class"] = "NXenvironment"
self.safe_dataset(group=end_station, name="temperature", device="temperature")
self.safe_dataset(group=end_station, name="magnetic_field_x", device="field_x")
self.safe_dataset(group=end_station, name="magnetic_field_z", device="field_z")
adc_signals = instrument.create_group("adc_signals")
adc_signals.attrs["NX_class"] = "NXdetector"
for signal_name in self._MONITOR_SIGNALS:
self.safe_dataset(
group=adc_signals, name=signal_name, device="signals", signal=signal_name
)
for group_name, description, device_name in self._KEITHLEY_GROUPS:
electrometer = instrument.create_group(group_name)
electrometer.attrs["NX_class"] = "NXdetector"
electrometer.create_dataset(name="description", data=description)
self.safe_dataset(group=electrometer, name="gain_code", device=device_name)
##############################
#### NXdata ####
##############################
self._populate_default_nxdata(data)
def _populate_default_nxdata(self, data_group) -> None:
has_otf_data = self.get_entry("otf", signal="edata") is not None
if has_otf_data:
self.safe_dataset(group=data_group, name="edata", device="otf", signal="edata")
self.safe_dataset(group=data_group, name="data", device="otf", signal="data")
data_group.attrs["signal"] = "data"
self.safe_dataset(group=data_group, name="idata", device="otf", signal="idata")
self.safe_dataset(group=data_group, name="fdata", device="otf", signal="fdata")
data_group.attrs["axes"] = ["edata"]
auxiliary_signals = [
signal_name
for signal_name in ("idata", "fdata")
if self.get_entry("otf", signal=signal_name) is not None
]
if auxiliary_signals:
data_group.attrs["auxiliary_signals"] = auxiliary_signals
axis_target = self._axis_target()
if axis_target and not has_otf_data:
self.safe_dataset(group=data_group, name="energy", device="energy")
data_group.attrs["axes"] = ["energy"]
elif axis_target:
self.safe_dataset(group=data_group, name="energy", device="energy")
found_signal = None
for signal in self._MONITOR_SIGNALS:
if self.get_entry("signals", signal=signal) is None:
continue
self.safe_dataset(group=data_group, name=signal, device="signals", signal=signal)
if found_signal is None:
found_signal = signal
if found_signal and not has_otf_data:
data_group.attrs["signal"] = found_signal
elif self.get_entry("energy") is not None and not has_otf_data:
data_group.attrs["signal"] = "energy"
def _axis_target(self) -> str | None:
if self.get_entry("energy") is not None:
return "/entry/instrument/beam_energy/energy"
if self.get_entry("mono") is not None:
return "/entry/instrument/monochromator/energy"
return None