refactor: eiger9m updates, operation in gating mode
This commit is contained in:
parent
7de0ff236c
commit
053f1d9181
@ -1,5 +1,6 @@
|
||||
import enum
|
||||
import time
|
||||
from typing import List
|
||||
from typing import Any, List
|
||||
import numpy as np
|
||||
|
||||
from ophyd import EpicsSignal, EpicsSignalRO, EpicsSignalWithRBV
|
||||
@ -10,20 +11,26 @@ from ophyd.areadetector.plugins import FileBase
|
||||
from bec_lib.core import BECMessage, MessageEndpoints
|
||||
from bec_lib.core.file_utils import FileWriterMixin
|
||||
from bec_lib.core import bec_logger
|
||||
from ophyd_devices.utils import bec_utils as bec_utils
|
||||
|
||||
from std_daq_client import StdDaqClient
|
||||
|
||||
from .bec_scaninfo_mixin import BecScaninfoMixin
|
||||
from ophyd_devices.epics.devices.bec_scaninfo_mixin import BecScaninfoMixin
|
||||
|
||||
|
||||
logger = bec_logger.logger
|
||||
|
||||
|
||||
class EigerError(Exception):
|
||||
pass
|
||||
|
||||
|
||||
class SlsDetectorCam(CamBase, FileBase):
|
||||
detector_type = ADCpt(EpicsSignalRO, "DetectorType_RBV")
|
||||
setting = ADCpt(EpicsSignalWithRBV, "Setting")
|
||||
delay_time = ADCpt(EpicsSignalWithRBV, "DelayTime")
|
||||
threshold_energy = ADCpt(EpicsSignalWithRBV, "ThresholdEnergy")
|
||||
beam_energy = ADCpt(EpicsSignalWithRBV, "BeamEnergy")
|
||||
enable_trimbits = ADCpt(EpicsSignalWithRBV, "Trimbits")
|
||||
bit_depth = ADCpt(EpicsSignalWithRBV, "BitDepth")
|
||||
num_gates = ADCpt(EpicsSignalWithRBV, "NumGates")
|
||||
@ -57,6 +64,27 @@ class SlsDetectorCam(CamBase, FileBase):
|
||||
json_detector_mode = ADCpt(EpicsSignalWithRBV, "JsonDetectorMode")
|
||||
|
||||
|
||||
class TriggerSource(int, enum.Enum):
|
||||
AUTO = 0
|
||||
TRIGGER = 1
|
||||
GATING = 2
|
||||
BURST_TRIGGER = 3
|
||||
|
||||
|
||||
class DetectorState(int, enum.Enum):
|
||||
IDLE = 0
|
||||
ERROR = 1
|
||||
WAITING = 2
|
||||
FINISHED = 3
|
||||
TRANSMITTING = 4
|
||||
RUNNING = 5
|
||||
STOPPED = 6
|
||||
STILL_WAITING = 7
|
||||
INITIALIZING = 8
|
||||
DISCONNECTED = 9
|
||||
ABORTED = 10
|
||||
|
||||
|
||||
class Eiger9mCsaxs(DetectorBase):
|
||||
"""Eiger 9M detector for CSAXS
|
||||
|
||||
@ -81,6 +109,7 @@ class Eiger9mCsaxs(DetectorBase):
|
||||
configuration_attrs=None,
|
||||
parent=None,
|
||||
device_manager=None,
|
||||
sim_mode=False,
|
||||
**kwargs,
|
||||
):
|
||||
super().__init__(
|
||||
@ -92,77 +121,128 @@ class Eiger9mCsaxs(DetectorBase):
|
||||
parent=parent,
|
||||
**kwargs,
|
||||
)
|
||||
self.device_manager = device_manager
|
||||
if device_manager is None and not sim_mode:
|
||||
raise EigerError("Add DeviceManager to initialization or init with sim_mode=True")
|
||||
|
||||
self.name = name
|
||||
self.scaninfo.username = "e21206"
|
||||
# TODO once running from BEC
|
||||
# self.scaninfo.username = self.device_manager.producer.get(MessageEndpoints.account()).decode()
|
||||
self.wait_for_connection() # Make sure to be connected before talking to PVs
|
||||
if not sim_mode:
|
||||
self._producer = self.device_manager.producer
|
||||
self.device_manager = device_manager
|
||||
else:
|
||||
self._producer = bec_utils.MockProducer()
|
||||
self.device_manager = bec_utils.MockDeviceManager()
|
||||
self.scaninfo = BecScaninfoMixin(device_manager, sim_mode)
|
||||
# TODO
|
||||
self.scaninfo.username = "e21206"
|
||||
self.service_cfg = {"base_path": f"/sls/X12SA/data/{self.scaninfo.username}/Data10/"}
|
||||
self.filewriter = FileWriterMixin(self.service_cfg)
|
||||
self.reduce_readout = 1e-3 # 3 ms
|
||||
self.triggermode = 0 # 0 : internal, scan must set this if hardware triggered
|
||||
self.mokev = 12
|
||||
self._init_eiger9m()
|
||||
self._init_standard_daq()
|
||||
|
||||
self.service_cfg = {"base_path": f"/sls/X12SA/data/{self.scaninfo.username}/Data10/data/"}
|
||||
self.filewriter = FileWriterMixin(self.service_cfg)
|
||||
self.scaninfo = BecScaninfoMixin(device_manager)
|
||||
self._producer = self.device_manager.producer
|
||||
self.readout = 0.003 # 3 ms
|
||||
self.triggermode = 0 # 0 : internal, scan must set this if hardware triggered
|
||||
# self.mokev = self.device_manager.devices.mokev.read()[
|
||||
# self.device_manager.devices.mokev.name
|
||||
# ]["value"]
|
||||
|
||||
def _init_eiger9m(self) -> None:
|
||||
"""Init parameters for Eiger 9m"""
|
||||
pass
|
||||
self._set_det_threshold()
|
||||
self._set_trigger(TriggerSource.GATING)
|
||||
self.cam.acquire.set(0)
|
||||
|
||||
def _update_std_cfg(self, cfg_key: str, value: Any) -> None:
|
||||
cfg = self.std_client.get_config()
|
||||
old_value = cfg.get(cfg_key)
|
||||
if old_value is None:
|
||||
raise EigerError(
|
||||
f"Tried to change entry for key {cfg_key} in std_config that does not exist"
|
||||
)
|
||||
if not isinstance(value, type(old_value)):
|
||||
raise EigerError(
|
||||
f"Type of new value {type(value)}:{value} does not match old value {type(old_value)}:{old_value}"
|
||||
)
|
||||
cfg.update({cfg_key: value})
|
||||
logger.info(f"Updated std_daq config for key {cfg_key} from {old_value} to {value}")
|
||||
|
||||
def _init_standard_daq(self) -> None:
|
||||
self.std_rest_server_url = "http://xbl-daq-29:5000"
|
||||
self.std_client = StdDaqClient(url_base=self.std_rest_server_url)
|
||||
self.std_client.stop_writer()
|
||||
timeout = 0
|
||||
# TODO check std_daq status
|
||||
while not self.std_client.std_status["state"] == "READY":
|
||||
self._update_std_cfg("writer_user_id", int(self.scaninfo.username.strip(" e")))
|
||||
while not self.std_client.get_status()["state"] == "READY":
|
||||
time.sleep(0.1)
|
||||
timeout = timeout + 0.1
|
||||
if timeout > 2:
|
||||
logger.info("Timeout of STD")
|
||||
|
||||
# TODO check status after sleep
|
||||
raise EigerError(
|
||||
f"Std client not in READY state, returns: {self.std_client.get_status()}"
|
||||
)
|
||||
|
||||
def _prep_det(self) -> None:
|
||||
self._set_det_threshold()
|
||||
self._set_acquisition_params()
|
||||
self._set_trigger(TriggerSource.TRIGGER)
|
||||
|
||||
def _set_det_threshold(self) -> None:
|
||||
# threshold_energy PV exists on Eiger 9M?
|
||||
factor = 1
|
||||
if self.cam.threshold_energy._metadata["units"] == "eV":
|
||||
factor = 1000
|
||||
setp_energy = int(self.mokev * factor)
|
||||
energy = self.cam.beam_energy.read()[self.cam.beam_energy.name]["value"]
|
||||
if setp_energy != energy:
|
||||
self.cam.beam_energy.set(setp_energy) # .wait()
|
||||
threshold = self.cam.threshold_energy.read()[self.cam.threshold_energy.name]["value"]
|
||||
if not np.isclose(self.mokev / 2, threshold, rtol=0.05):
|
||||
self.cam.threshold_energy.set(self.mokev / 2)
|
||||
if not np.isclose(setp_energy / 2, threshold, rtol=0.05):
|
||||
self.cam.threshold_energy.set(setp_energy / 2) # .wait()
|
||||
|
||||
def _set_acquisition_params(self) -> None:
|
||||
self.cam.acquire_time.set(self.scaninfo.exp_time)
|
||||
self.cam.acquire_period.set(self.scaninfo.exp_time + self.readout)
|
||||
self.cam.num_images.set(self.scaninfo.num_frames)
|
||||
self.cam.num_exposures.set(1)
|
||||
# trigger_mode vs timing mode ??!!
|
||||
self.cam.timing_mode.set(self.triggermode)
|
||||
# self.cam.acquire_time.set(self.scaninfo.exp_time)
|
||||
# Set acquisition parameters slightly shorter then cycle
|
||||
# self.cam.acquire_period.set(
|
||||
# self.scaninfo.exp_time + (self.scaninfo.readout_time - self.reduce_readout)
|
||||
# )
|
||||
self.cam.num_cycles.set(self.scaninfo.num_frames)
|
||||
self.cam.num_frames.set(1)
|
||||
|
||||
def _set_trigger(self, trigger_source: TriggerSource) -> None:
|
||||
"""Set trigger source for the detector, either directly to value or TriggerSource.* with
|
||||
AUTO = 0
|
||||
TRIGGER = 1
|
||||
GATING = 2
|
||||
BURST_TRIGGER = 3
|
||||
"""
|
||||
value = int(trigger_source)
|
||||
self.cam.timing_mode.set(value)
|
||||
|
||||
def _prep_file_writer(self) -> None:
|
||||
self.filepath = self.filewriter.compile_full_filename(
|
||||
self.scaninfo.scan_number, "eiger", 1000, 5, True
|
||||
self.scaninfo.scan_number, "eiger.h5", 1000, 5, True
|
||||
)
|
||||
logger.info(f" std_daq output filepath {self.filepath}")
|
||||
self.std_client.start_writer_async(
|
||||
{"output_file": self.filepath, "n_images": self.scaninfo.num_frames}
|
||||
)
|
||||
logger.info("Waiting for std daq to be armed")
|
||||
while True:
|
||||
det_ctrl = self.std_client.get_status()["acquisition"]["state"]
|
||||
if det_ctrl == "WAITING_IMAGES":
|
||||
break
|
||||
time.sleep(0.005)
|
||||
|
||||
def _close_file_writer(self) -> None:
|
||||
self.std_client.stop_writer()
|
||||
pass
|
||||
|
||||
def stage(self) -> List[object]:
|
||||
"""stage the detector and file writer"""
|
||||
# TODO remove once running from BEC
|
||||
# self.scaninfo.load_scan_metadata()
|
||||
self.scaninfo.scan_number = 10
|
||||
self.scaninfo.exp_time = 0.5
|
||||
self.scaninfo.num_frames = 3
|
||||
self.mokev = 12
|
||||
self.triggermode = 0
|
||||
self.scaninfo.load_scan_metadata()
|
||||
self.mokev = self.device_manager.devices.mokev.read()[
|
||||
self.device_manager.devices.mokev.name
|
||||
]["value"]
|
||||
|
||||
self._prep_det()
|
||||
self._prep_file_writer()
|
||||
@ -172,32 +252,43 @@ class Eiger9mCsaxs(DetectorBase):
|
||||
MessageEndpoints.public_file(self.scaninfo.scanID, "eiger9m"),
|
||||
msg.dumps(),
|
||||
)
|
||||
self.arm_acquisition()
|
||||
logger.info("Waiting for detector to be armed")
|
||||
while True:
|
||||
det_ctrl = self.cam.detector_state.read()[self.cam.detector_state.name]["value"]
|
||||
if det_ctrl == int(DetectorState.RUNNING):
|
||||
break
|
||||
time.sleep(0.005)
|
||||
logger.info("Detector is armed")
|
||||
|
||||
return super().stage()
|
||||
|
||||
def unstage(self) -> List[object]:
|
||||
"""unstage the detector and file writer"""
|
||||
self.timing_mode = 0
|
||||
self._close_file_writer()
|
||||
std_status = self.std_client.get_status()
|
||||
if (
|
||||
not std_status["acquisition"]["message"] == "Completed"
|
||||
or std_status["acquisition"]["state"] == "FINISHED"
|
||||
):
|
||||
logger.info(std_status)
|
||||
# TODO add BEC error message
|
||||
# raise
|
||||
# TODO check detector stateX12SA-ES-EIGER9M:cam1:DetectorState_RBV
|
||||
logger.info("Waiting for eiger9M to return from acquisition")
|
||||
while True:
|
||||
det_ctrl = self.cam.acquire.read()[self.cam.acquire.name]["value"]
|
||||
if det_ctrl == 0:
|
||||
break
|
||||
time.sleep(0.005)
|
||||
|
||||
state = True
|
||||
msg = BECMessage.FileMessage(file_path=self.filepath, done=True, successful=state)
|
||||
self.producer.set_and_publish(
|
||||
MessageEndpoints.public_file(self.metadata["scanID"], self.name),
|
||||
msg.dumps(),
|
||||
)
|
||||
logger.info("Waiting for std daq to receive images")
|
||||
while True:
|
||||
det_ctrl = self.std_client.get_status()["acquisition"]["state"]
|
||||
if det_ctrl == "FINISHED":
|
||||
break
|
||||
time.sleep(0.005)
|
||||
# Message to BEC
|
||||
# state = True
|
||||
|
||||
# msg = BECMessage.FileMessage(file_path=self.filepath, done=True, successful=state)
|
||||
# self._producer.set_and_publish(
|
||||
# MessageEndpoints.public_file(self.metadata["scanID"], self.name),
|
||||
# msg.dumps(),
|
||||
# )
|
||||
return super().unstage()
|
||||
|
||||
def acquire(self) -> None:
|
||||
def arm_acquisition(self) -> None:
|
||||
"""Start acquisition in software trigger mode,
|
||||
or arm the detector in hardware of the detector
|
||||
"""
|
||||
@ -206,7 +297,13 @@ class Eiger9mCsaxs(DetectorBase):
|
||||
def stop(self, *, success=False) -> None:
|
||||
"""Stop the scan, with camera and file writer"""
|
||||
self.cam.acquire.set(0)
|
||||
self.std_client.stop_writer()
|
||||
self._close_file_writer()
|
||||
self.unstage()
|
||||
super().stop(success=success)
|
||||
self._stopped = True
|
||||
|
||||
|
||||
# Automatically connect to test environmenr if directly invoked
|
||||
if __name__ == "__main__":
|
||||
eiger = Eiger9mCsaxs(name="eiger", prefix="X12SA-ES-EIGER9M:", sim_mode=True)
|
||||
eiger.stage()
|
||||
|
Loading…
x
Reference in New Issue
Block a user