x01dcandClaude Sonnet 5 bcdfc12a88 fix(LamNI): decouple smear composite display from live acquisition channel
The "camera running" toggle (IDSCamera.live_mode_enabled) was flapping
on/off during the smear sweep, and on real hardware that's genuinely
slow (starting/stopping the live acquisition thread has real driver
overhead, unlike the simulator). Root cause: composite pushes shared
the same device_preview channel the live thread continuously publishes
to, so live_mode_enabled had to be toggled off around every push to
keep the composite from being instantly overwritten.

Give the composite its own channel instead:
- IDSCamera gains a smear_preview PreviewSignal (no rotation_90/
  transpose configured -- composite data is already display-oriented)
  and push_smear_preview(), mirroring push_preview_image() but fully
  decoupled from the live channel.
- XRayEye gains set_live_view_signal() to switch which camera signal
  the live Image view displays, defaulting to the normal channel for
  every fresh GUI instance; on_live_view_enabled() now uses whichever
  signal is currently selected instead of a hardcoded constant.
- _smear_sweep() switches the GUI to "smear_preview" for the sweep and
  pushes composite updates there -- live_mode_enabled is never touched
  at all (just ensured on at the start, exactly like _live_sweep()).
  The GUI is deliberately left on the composite after a successful
  sweep until the caller has collected the operator's click, then
  switched back to "image"; on KeyboardInterrupt it's switched back
  immediately.

This removes the resume_live/hold_display_s toggle-avoidance mechanism
added in def9bf4, which is no longer needed with a dedicated channel.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-24 16:08:01 +02:00
2025-05-24 11:37:51 +02:00
2026-07-12 23:16:18 +02:00

cSAXS BEC

cSAXS specific plugins and configs for BEC This document guides you through the procedure to spin up BEC at the beamline for a new experiment (e-account). You might want to run cSAXS copy scripts before in case you want to have the former data structure to be preserved.

Overview

  • Clone cSAXS BEC repository into e-account (e.g. into ~/Data10/software/.)
  • Start Epics iocs
  • Start BEC, BEC server and load/modify the device config with relevant hardware
  • BEC commands

Clone cSAXS BEC repository

Clone the current cSAXS BEC repository from GIT into the new e-account. Create directory

mkdir ~/Data10/software
cd ~/Data10/software

Clone repository

git clone https://gitlab.psi.ch/bec/csaxs_bec.git

Start epics iocs

You can start up the iocs while the ./setup_bec.sh script is running. Be aware though that the scripts requires you to interact with it.

DelayGenerator

Open a new tab in a terminal in comp1/comp2 or cons1 and follow the commands below:

ssh gac-x12sa@localhost
cd ~/delaygen
iocsh -7.0.6 startup.script

Be aware -7.0.6 is referring to the current epics version and might change in future (SLS 2.0). To start the epics panel (only if needed), run in a new shell

caqtdm -noMsg -macro P=delaygen:,R=DG1: srsDG645.ui

More notes on usages and cabelling of DDGs. Currently 3 generators are used:

  • DDG1 for detectors (EXT Enable from SGalil stages, T0 to DDG2, AB for eiger, CD for Falcon, EF for Pilatus_2)
  • DDG2 for mcs card (ext. enable from DDG1, AB to mcs card)
  • DDG3 for fast shutter and mcs enable (AB short pulse to enable MCS (needed!!), CD to keep FSH open )

Eiger

Open a new tab in a terminal in comp1/comp2 or cons1 and follow the commands below:

ssh gac-x12sa@localhost
cd ~/Software/Eiger/
./launch_ioc

A live view of status and images for std_daq can be found here xbl-daq-29:5000.

Pilatus_2

First, start the cam server. Connect to the computer and follow the instructions printed after connecting:

ssh det@x12sa-pd-2 (Pilatus2)

The cam server will open, wait until you see **. Nex step, open a new tab in a terminal in comp1/comp2 or cons1 and follow the commands below:

ssh gac-x12sa@localhost
cd ~/Software/Pilatus300K/
./launch_epics

FalconX1

Open a new tab in a terminal in comp1/comp2 or cons1 (logged in as the current e-account) and follow the commands:

ssh x12sa-cons-01
cd /ioc/X12SA-PC-FALCONX1/
iocsh -7.0.6 startup.script

Be aware -7.0.6 is referring to the current epics version and might change in future (SLS 2.0)

Start BEC, BEC server and load device config

Step 1 needs to have finished for continuing with these steps. What remains now is to start the bec server. Connect to pc15543 and open a new terminal to run:

cd ~/Data10/software
source bec_venv/bin/activate
bec-server start
tmux attach -t bec

Open another teminal on pc15543 and start BEC:

cd ~/Data10/software
source bec_venv/bin/activate
bec

Note: In case there is a warning after starting BEC that it was not able to import scilog, you will have to pip install scilog in the bec_venv to be able to send printouts to scilog from the command line. Within a new terminal:

cd ~/Data10/software
source bec_venv/bin/activate
pip install scilog

Device config from csaxs-bec plugins

bec.config.update_session_with_file('/sls/X12SA/data/e20639/Data10/software/csaxs-bec/bec_plugins/configs/bec_device_config_sastt.yaml')
bec.config.save_current_session('~/Data10/software/current_config.yaml')

The second command is helpful if you adjust limits of motors, which will then be stored in the config and loaded if a reload of the configuration is needed.

BEC commands

A number of commands that are useful:

To move devices that are added in the config:

umv(dev.samx, 0) #absolute
umvr(dev.samx, 0) #relative
dev.samx.wm #print motor position and limits
dev.samx.limits = [low_limit, high_limit] # To set limits, note, same lower and higher limit, e.g. [0, 0] means no limits!!

Scans:

scans.acquire(exp_time = 0.5, frames_per_trigger=10, readout_time=3e-3) # equivalent to a loopscan 30 0.5
scans.line_scan(dev.samx, -1, 1, steps=20, exp_time=0.5, readout_time=3e-3, relative=True) # optional, add frames_per_trigger =10 for burst acquisition at each step
#Scan 2 motors in a step scan at the same time
scans.line_scan(dev.samx, -1, 1, dev.samy, -1, 1, steps=20, exp_time=0.5, readout_time =3e-3, relative=True) # step scan with 20 steps, again frames_per_trigger can be added for burst at each point
scans.sgalil_grid(start_y = , end_y = , interval_y = , start_x=, end_x=, interval_x =, exp_time=0.5, readout_time=3e-3, relative=True)
S
Description
cSAXS specific plugins and configs for BEC
Readme BSD-3-Clause
24 MiB
Languages
Python 99%