Holler
3fac5ff9e3 fixed issue with move_to_start 2025-09-10 15:31:50 +02:00
Holler
81a63d0317 fixes 2025-09-10 15:31:50 +02:00
Holler
7513955674 flomni fixes 2025-09-10 15:31:50 +02:00
5 changed files with 23 additions and 14 deletions

View File

@@ -416,7 +416,7 @@ class FlomniSampleTransferMixin:
def laser_tracker_on(self):
dev.rtx.controller.laser_tracker_on()
time.sleep(0.2)
self._laser_tracker_check_signalstrength()
dev.rtx.controller.laser_tracker_check_signalstrength()
def laser_tracker_off(self):
dev.rtx.controller.laser_tracker_off()
@@ -429,11 +429,11 @@ class FlomniSampleTransferMixin:
def feedback_enable_with_reset(self):
self.device_manager.devices.rtx.controller.feedback_enable_with_reset()
self.rt_feedback_status()
self.feedback_status()
def feedback_enable_without_reset(self):
self.device_manager.devices.rtx.controller.feedback_enable_without_reset()
self.rt_feedback_status()
self.feedback_status()
def feedback_status(self):
feedback_status = self.device_manager.devices.rtx.controller.feedback_is_running()

View File

@@ -63,6 +63,8 @@ class OmnyAlignment(BECWidget, QWidget):
self.ui.liveViewSwitch.enabled.connect(self.on_live_view_enabled)
self.ui.moveUpButton.clicked.connect(self.on_move_up)
@property
def enable_live_view(self):
@@ -102,7 +104,6 @@ class OmnyAlignment(BECWidget, QWidget):
image.disconnect_monitor("cam200")
@property
def enable_move_buttons(self):
move_up:QPushButton = self.ui.moveUpButton

View File

@@ -172,7 +172,7 @@ class FlomniFermatScan(SyncFlyScanBase):
self.device_manager.connector.raise_alarm(
severity=0,
alarm_type="LaserTrackerSignalStrength",
source="rtx",
source={"device": "rtx", "reason": "low signal strength", "method": "_prepare_setup_part2"},
metadata={},
msg="Signal strength of the laser tracker is low, sufficient to continue. Realignment recommended!",
)
@@ -295,9 +295,10 @@ class FlomniFermatScan(SyncFlyScanBase):
logger.debug("reading monitors")
# yield from self.device_rpc("rtx", "controller.kickoff")
def return_to_start(self):
def move_to_start(self):
"""return to the start position"""
# in flomni, we need to move to the start position of the next scan
# in flomni, we need to move to the start position of the next scan, which is the end position of the current scan
# this method is called in finalize and overwrites the default move_to_start()
if isinstance(self.positions, np.ndarray) and len(self.positions[-1]) == 3:
yield from self.stubs.set(device=["rtx", "rty", "rtz"], value=self.positions[-1])
return

View File

@@ -280,9 +280,10 @@ class OMNYFermatScan(SyncFlyScanBase):
logger.debug("reading monitors")
# yield from self.device_rpc("rtx", "controller.kickoff")
def return_to_start(self):
def move_to_start(self):
"""return to the start position"""
# in omny, we need to move to the start position of the next scan
# in omny, we need to move to the start position of the next scan, which is the end position of the current scan
# this method is called in finalize and overwrites the default move_to_start()
if isinstance(self.positions, np.ndarray) and len(self.positions[-1]) == 3:
yield from self.stubs.set(device=["rtx", "rty", "rtz"], value=self.positions[-1])
return

View File

@@ -147,8 +147,14 @@ Following functions exist to move the optics in and out, with self-explaining na
The position feedback in flOMNI is controlled in closed loop to an interferometric position measurement. To show the signal of the interferometers:
`flomni.show_signal_strength_interferometer()`
Typical values with proper alignment, sample stage at the measurement position and laser tracker running are
_TODO_
Typical values with proper alignment, sample stage at the measurement position and laser tracker running are in the range of
| Axis | Value |
| --- | --- |
| 0 | 13681.0 |
| 1 | 12383.0 |
| 2 | 10716.0 |
| 3 | 11032.0 |
#### Laser tracker commands
@@ -162,10 +168,10 @@ The horizontal interferometer is built according to the [tracking interferometer
#### Interferometer feedback commands
The closed loop control of the Piezo stages can be controlled by
- `flomni.rt_feedback_enable_with_reset()`.
- `flomni.feedback_feedback_enable_with_reset()`.
_There is also an enable without reset, which is used during tomography scans, when using coarse stages to increase the scan range. It should not be required to use manually._
- `flomni.rt_feedback_disable()`
- `flomni.rt_feedback_status()`
- `flomni.feedback_disable()`
- `flomni.feedback_status()`
### Scanning in 2D and sample alignment