Compare commits

..

3 Commits

Author SHA1 Message Date
d99b44b619 refactor(configs):Migrate deviceClass for EpicsMotorEX to EpicsUserMotorVME
All checks were successful
CI for csaxs_bec / test (pull_request) Successful in 1m30s
CI for csaxs_bec / test (push) Successful in 1m30s
2025-12-11 07:52:52 +01:00
x12sa
dbab981ac2 add micfoc and change some motor settings 2025-12-11 07:52:52 +01:00
x12sa
bdd7f1767f new yaml file sastt for sastt setup 2025-12-11 07:52:52 +01:00
2 changed files with 101 additions and 5 deletions

View File

@@ -115,7 +115,7 @@ samy:
softwareTrigger: false
micfoc:
description: Focusing motor of Microscope stage
deviceClass: ophyd_devices.devices.EpicsMotorEx
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES06
motor_resolution: 0.00125
@@ -133,7 +133,7 @@ micfoc:
softwareTrigger: false
owis_samx:
description: Owis motor stage samx
deviceClass: ophyd_devices.devices.EpicsMotorEx
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES01
motor_resolution: 0.00125
@@ -151,7 +151,7 @@ owis_samx:
softwareTrigger: false
owis_samy:
description: Owis motor stage samx
deviceClass: ophyd_devices.devices.EpicsMotorEx
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES02
motor_resolution: 0.00125
@@ -169,7 +169,7 @@ owis_samy:
softwareTrigger: false
rotx:
description: Rotation stage rotx
deviceClass: ophyd_devices.devices.EpicsMotorEx
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES05
motor_resolution: 0.0025
@@ -190,7 +190,7 @@ rotx:
softwareTrigger: false
roty:
description: Rotation stage rotx
deviceClass: ophyd_devices.devices.EpicsMotorEx
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES04
motor_resolution: 0.0025

View File

@@ -0,0 +1,96 @@
samx:
description: Owis motor stage samx
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES01
motor_resolution: 0.00125
base_velocity: 0.0625
velocity: 10
backlash_distance: 0.125
acceleration: 0.2
user_offset_dir: 1
deviceTags:
- cSAXS
- owis_samx
onFailure: buffer
enabled: true
readoutPriority: baseline
softwareTrigger: false
samy:
description: Owis motor stage samy
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES02
motor_resolution: 0.00125
base_velocity: 0.0625
velocity: 10
backlash_distance: 0.125
acceleration: 0.2
user_offset_dir: 0
deviceTags:
- cSAXS
- owis_samx
onFailure: buffer
enabled: true
readoutPriority: baseline
softwareTrigger: false
rotx:
description: Rotation stage rotx
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES03
motor_resolution: 0.0025
base_velocity: 0.5
velocity: 7.5
backlash_distance: 0.25
acceleration: 0.2
user_offset_dir: 1
limits:
- -0.1
- 0.1
deviceTags:
- cSAXS
- rotx
onFailure: buffer
enabled: true
readoutPriority: baseline
softwareTrigger: false
roty:
description: Rotation stage roty
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES04
motor_resolution: 0.0025
base_velocity: 0.5
velocity: 7.5
backlash_distance: 0.25
acceleration: 0.2
user_offset_dir: 0
limits:
- -0.1
- 0.1
deviceTags:
- cSAXS
- roty
onFailure: buffer
enabled: true
readoutPriority: baseline
softwareTrigger: false
micfoc:
description: Focusing motor of Microscope stage
deviceClass: ophyd_devices.devices.psi_motor.EpicsUserMotorVME
deviceConfig:
prefix: X12SA-ES2-ES05
motor_resolution: 0.00125
base_velocity: 0.25
velocity: 2.5
backlash_distance: 0.125
acceleration: 0.4
user_offset_dir: 0
deviceTags:
- cSAXS
- micfoc
onFailure: buffer
enabled: true
readoutPriority: baseline
softwareTrigger: false