Implements docs/plans/flomni-fermat-asymmetry.md as written: generate the
spiral against an inflated fovy half-width (length_axis2 * fermat_asymmetry),
then compress the accepted y-coordinate back down by the ratio before
storing -- keeps x spacing fixed at step, scales y spacing by the ratio,
preserves the requested FOV. Composes with the already-landed sub-step
randomization: the offset is subtracted at the raw (pre-compression) scale
on both axes, before the inflated-window check, so the offset's phase-shift
stays proportional to the local spacing on both axes.
Wired through the scan class (FlomniFermatScan), Flomni's global var +
queue/CLI plumbing (_TOMO_SCAN_PARAM_NAMES, scan_kwargs, tomo_parameters()
print/prompt, _set_default_tomo_params()), and the tomo_params Qt widget
(new field with a "?" help button, following the widget's existing
offsets-section help-button pattern).
Added tests verifying the inflate/compress math directly (against an
equivalent call with an inflated FOV and fermat_asymmetry=1.0, same seed)
rather than via an approximate spacing-ratio heuristic -- a first attempt
at the latter proved too noisy on a Fermat spiral to assert reliably.
Updated the flOMNI user docs and the OMNY port TODO (out of scope here,
explicitly excludes LamNI per the plan).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Lx3KffiFyyDMKT8vvPENUW
Restores the legacy spec behavior of drawing a fresh random offset
(uniform in [0, step)) per call and shifting the sampling lattice by
it before the FOV crop check -- decorrelates position-tied
reconstruction errors that otherwise accumulate into ring artifacts
across a ptycho-tomography series. Applied identically to all three
generators (get_flomni_fermat_spiral_pos, get_omny_fermat_spiral_pos,
get_lamni_fermat_spiral_pos), same scalar offset for x and y, matching
the historical spec. New `seed` parameter (default None = fresh
randomization) allows deterministic/reproducible calls.
The four call sites that predict Fermat point counts ahead of a real
scan (flomni.py/lamni.py's _expected_fermat_position_count(),
tomo_params.py's _compute_fermat_positions_flomni/_lamni) now pin
seed=0 so their own estimates stay reproducible across repeated calls;
their docstrings note the real scan's count can differ by a point or
two near the threshold due to the randomization. Updated the affected
tests to compare against a matching seed=0 instead of an independent
random draw.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Lx3KffiFyyDMKT8vvPENUW
Legacy spec code drew a fresh random offset per projection to shift the
Fermat lattice phase before FOV cropping (mitigates ptycho-tomo ring
artifacts). None of the current BEC Fermat spiral generators (flOMNI,
OMNY, LamNI) draw this offset -- all three are fully deterministic.
Plan only, not implemented; applies identically across all three setups.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Lx3KffiFyyDMKT8vvPENUW
Introduces fermat_asymmetry, a ratio of x spacing to y spacing for the
Flomni Fermat-spiral scan: x spacing stays fixed at step while y spacing
scales by the ratio, with the requested field of view preserved (so the
total position count changes with the ratio). Covers the scan class,
global var/CLI, queuing, and the tomo_params Qt widget. Plan only, not
implemented -- written during a live beamtime experiment.
Also flags this for a future OMNY port (same Fermat-spiral algorithm),
explicitly excluding LamNI.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01WW873PFzsY4N1r65aQgfFn
Once height-centering fixes the sample's vertical position during the
flomni alignment procedure, the selection box for the 0-180 deg rotation
steps should auto-snap to the FZP height instead of requiring manual
vertical placement each time. Plan only, not implemented.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01CpPtD7tCRwRZZnREhWcJi8
Add a temporary single-camera (ID 41, color) device config for manually
verifying the new exposure/auto-gain controls against real hardware
outside a live beamtime, and update the plan's status accordingly.
No code changes -- IDSCamera and the xrayeye widget are both used
during beamtimes. Revises the earlier plain-method design to
Cpt(Signal, kind=Kind.config) (mirroring live_mode_enabled) so the
xrayeye widget can read exposure/auto-exposure/auto-gain state via
its existing device_read_configuration subscription instead of
polling the device, and adds the corresponding GUI control knobs
(auto-exposure/auto-gain toggles, exposure spinbox) to the plan.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_014s92UHyMfov6Fb934pGqcU
No code changes -- IDSCamera is in production use during beamtimes.
Documents the intended USER_ACCESS additions (get/set_exposure_time,
set_auto_exposure_enabled, set_auto_gain_enabled) for a future session.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_014s92UHyMfov6Fb934pGqcU