@@ -57,6 +57,8 @@ A backup environment is currently located at:
````
if all else fails.
## Getting git
The `git` installed on the cristallina consoles is from 2015, so we can use conda to provide us with an up-to-date version. E.g. with `miniconda` activated simply install using `conda install git`.
# sf_datafiles directly from github
- pip:
+192
View File
@@ -0,0 +1,192 @@
**HowTos**
Panels
* Launcher:
* `launcher`
* Aramis synoptics
* From launcher
* `caqtdm …`
* Aramis synoptic medm (Optics group version, used to move mirrors)
* Aramis
* Cameras:
* `caqtdm -noMsg -stylefile sfop.qss camsf.ui`
* (also “Cameras” button in Aramis Synoptic)
* X-ray eye camera:
* `caqtdm -macro NAME=SARES30-CAMS999-XE /sf/controls/config/qt/Camera/CameraExpert.ui`
* EVRs
* EVR specific panel in “Cameras”
* Cristallina EVR overall panel (includes scope/digitizer):
* `caqtdm -macro EEVR=SARES30-LTIM01-EEVR0,EEVRCHAN1=0,EEVRCHAN2=0,IOC=SARES30-LTIM01-EVR0,SYS=SARES30-LTIM01,DEVICE=EVR0,CALC=SARES30-LTIM01-EVR0,C1=I,C2=X,C3=Y,C4=S,C5=T,C6=U,C7=V,C8=W,C9=Z,DUM=SARES30-LTIM01-EVR0,SCP=SARES30-LSCP1-FNS,FMC=SARES30-LSCP1-CRISTA1,TITLE=SARES30-CVME-CRISTA1,BS=SARES30-CVME-CRISTA1,FMC2=,SCP2=-FNS S_LAS_IFC_SYS_V2.ui &`
* Screen panel: visualizes “camera bread stream”
* Does not work from any caqtdm panel (/sf/op/bin/screen_panel)
* `screen panel (/sf/cristallina/bin/screen_panel)`
* PBPSs
* From launcher in Photonics expert mode, Operation photonics menu, PBPS (diamond)
* > bash -c 'caqtdm -noMsg -stylefile sfop.qss -macro P=SAROP31-PBPS149,FED=SAROP31-CVME-PBPS1,LNK=9,PDL=4,PDR=3,PDD=2,PDU=1 PBPS_exp.ui'
* PPRMs / PSCR
* Launcher in Photonics expert mode → Aramis screens
* From caqtdm Aramis synoptic panel (also from medm Aramis synoptic panel)
* PSSS059 (single shot spectrometer)
* Motor panel: > caqtdm -noMsg -stylefile sfop.qss -macro P1=SARFE10-PSSS055,P2=SARFE10-PSSS059 PSSS_
* exp.ui (also button on Aramis synoptic)Setup panel (with energy, crystal and camera alignment features): > bash /sf/photo/src/apps/psss/bin/psss_panel (also launcher in Photonics expert mode)
* Setup panel dev: > bash /sf/photo/src/apps/psss_dev/bin/psss_panel
* Requires 100-200 uJ - so no less than 0.2 attenuation at OATT053
* Alignment procedure
* Alignment
* Energy scan about requested energy
* Crystal height scan
* Look at readback values “Xtal bender y-trans” and put in sensible range in PSSS window
* OATA150:
* >caqtdm -attach -macro "P=SAROP31-OATA150,PH_ENERGY=SARUN:FELPHOTENE" OATT_exp.ui
Change photon energy
* Launcher from Cristallina, mode Operation, Operation/Procedures>Aramis Photon Energy (K)
Beam synchronous DAQ with run_control
* Start run control:
* > /sf/jungfrau/bin/run_control, then chose pgroup
* Acquire pedestal
* From “Expert” panel in run control
* Acquire data (single point scan)
* “Run”
* Acquire scans
* In “Scan” panel set motor positions
* Check “Run scan”
* “Run”
* Set bs and ca channels
* Load files in “Configure” panel
* Set Jungfraus
* In “Configure” panel check JF detectors
Jungfrau 1.5M
* Start high voltage after power has been given to the detector:
* Power on in “Configure”
* Power off by disconnecting power cable
* 1Hz image stream
* web browser with _sf-daq-cristallina:5016_
Jungfrau 8M
* Start by toggling “lever button” for ~1sec → no high voltage yet
* Start high voltage after power has been given to the detector:
* Power on in “Configure”
* Stand by by toggling “lever button” for 1sec
* Power off by disconnecting power cable
* 1Hz image stream
* web browser with _sf-daq-cristallina:5017_
PBPS:
* Panel: > caqtdm -stylefile sfop.qss -macro P=SAROP31-PBPS149,IOC=SAROP31-CVME-PBPS149 S_FrontEndDigitizer_User.ui
* > module load psi-python38/2020.11
* > source activate /sf/photo/miniconda/
* > jupyter-notebook /sf/photo/src/PhotonDiagControl/Beamline/PBPS149_esc_short.ipynb
* Must be run but new calibration values cant be pushed to the process SAROP31-PBPS149_proc running on the camera server sf-daqsync-03.psi.ch:8881
Diode
PIPS Diode model …
Connected to ifc1210 digitizer in rack 0.Z719.75 (“electronics”)
uses (too) fast bias-tee and
Signal attenuated with 25 dB 3GHz attenuator
* Signal is on channel 0 of the scope on the Cristallina IFC1210
* Broadcasted to bread: waveform, signal-background, first computation output
pshell workbench:
* > pshell_cr
* Can be used for scans, not clear how it works
* Jungfrau not accessible
* Scan:
* Set positioners
* Set detectors: screen_panel ROI, bread channel
* See /sf/cristallina/config_pshell_cr/script/example.scan
Strip charts (pshell based):
* > strip_chart, then load wished strip chart from /sf/cristallina/config/strip_chart
* /sf/cristallina/config/strip_chart is read-only for gac-cristall
Correlation panel (pshell based):
* > correlation panel
Bsread stream:
* > bs receive …
* > bs avail (...)
* > bs config (?)
Channel access / epics:
* Make CA channels writable from sf-esc network:
* [https://git.psi.ch/controls_it/gfa_ansible_ca-gateways/-/blob/master/files/saresc-cagw.pvlist](https://git.psi.ch/controls_it/gfa_ansible_ca-gateways/-/blob/master/files/saresc-cagw.pvlist)
data-ui.psi.ch:
*
Mobile webcam:
* IP address in web browser: 129.129.221.71
NoMachine remote connections
* Define access list:
* [https://rama.psi.ch](https://rama.psi.ch)
* Instructions to connect:
* [https://www.psi.ch/en/photon-science-data-services/remote-interactive-access](https://www.psi.ch/en/photon-science-data-services/remote-interactive-access)
Set pointing:
A useful command is to switch between which slit is open or closed
###### caputq SARFE10-OAPU044:MOTOR_W 0.25; caputq SARFE10-OAPU044:MOTOR_H 0.25; caputq SARFE10-OAPU092:MOTOR_W 3.00; caputq SARFE10-OAPU092:MOTOR_H 3.00;
(to open the back slit and close the upstream one)
###### caputq SARFE10-OAPU044:MOTOR_W 3.00; caputq SARFE10-OAPU044:MOTOR_H 3.00; caputq SARFE10-OAPU092:MOTOR_W 0.25; caputq SARFE10-OAPU092:MOTOR_H 0.25;
(to do the opposite, open the front and close down the downstream slit)
To view the beam after both slits, use SAROP21-PPRM113 camera (from the screen_panel).