fix prepump config in bernina.py
This commit is contained in:
1 parent
e3d801a38c
commit
d63bc10779
1 file changed
+4
-4
@@ -228,16 +228,16 @@ namespace.mark_beamline(
|
||||
_prepump_config = {
|
||||
"gp": "SARES21-VMCP142-620", # common prevac-line gauge Gp base
|
||||
"roots_pump": "SARES21-VPFO140-750", # Roots pump base
|
||||
"p_target": 1e-3, # "pumped" threshold [mbar]
|
||||
"p_vent_target": 500.0, # "vented" threshold [mbar]
|
||||
"p_target": 0.5, # "pumped" threshold [mbar]
|
||||
"p_vent_target": 1000.0, # "vented" threshold [mbar]
|
||||
"lines": {
|
||||
"line1_usd": {
|
||||
"gauge": "SARES21-VMFR140-510", # G1 gauge base
|
||||
"gauge": "SARES21-VMCP140-600", # G1 gauge base
|
||||
"valve_prevac": "SARES21-VVPP140-300", # P1 roughing valve
|
||||
"valve_vent": "SARES21-VVPP142-340", # V1 vent valve
|
||||
},
|
||||
"line2_lic": {
|
||||
"gauge": "SARES21-VMCP141-531", # G2 gauge base
|
||||
"gauge": "SARES21-VMCP141-610", # G2 gauge base
|
||||
"valve_prevac": "SARES21-VVPP141-320", # P2 roughing valve
|
||||
"valve_vent": "SARES21-VVPP142-370", # V2 vent valve
|
||||
},
|
||||
|
||||
Reference in new issue