# HLA Service Control Parameters
|
|
|
|
record(mbbo, "$(DEVICE):CONTROL-SCRUB") {
|
|
field(DESC, "Scrubbing Mode")
|
|
field(ASG, "PROTECTED")
|
|
field(ZRST, "Off")
|
|
field(ZRVL, "0")
|
|
field(ONST, "Vertical Pinger")
|
|
field(ONVL, "1")
|
|
field(TWST, "Horizontal Pingers")
|
|
field(TWVL, "2")
|
|
field(THST, "Both Pingers")
|
|
field(THVL, "3")
|
|
field(FRST, "Vertical MBFB")
|
|
field(FRVL, "4")
|
|
field(FVST, "Horizontal MBFB")
|
|
field(FVVL, "5")
|
|
field(SXST, "Both MBFBs")
|
|
field(SXVL, "6")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-VACUUM-MAX") {
|
|
field(DESC, "Stop injection at this vacuum pressure")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "1e-9 mbar")
|
|
field(VAL, "360")
|
|
field(PREC, "3")
|
|
field(FLNK, "$(DEVICE):CONTROL-VACUUM-MAX-PLOT")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-VACUUM-DYN") {
|
|
field(DESC, "Stop injection at this vacuum pressure")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "1e-9 mbar")
|
|
field(VAL, "27")
|
|
field(PREC, "3")
|
|
field(FLNK, "$(DEVICE):CONTROL-VACUUM-DYN-PLOT")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-VACUUM-DYN-FRAC") {
|
|
field(DESC, "Fraction defining dynamic pressure ")
|
|
field(ASG, "PROTECTED")
|
|
field(VAL, "1.2")
|
|
field(PREC, "3")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-VACUUM-MIN") {
|
|
field(DESC, "Start injection at this vacuum pressure")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "1e-9 mbar")
|
|
field(VAL, "0")
|
|
field(PREC, "3")
|
|
field(FLNK, "$(DEVICE):CONTROL-VACUUM-MIN-PLOT")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(calc, "$(DEVICE):CONTROL-VACUUM-MAX-PLOT") {
|
|
field(DESC, "Stop injection at this vacuum pressure")
|
|
field(ASG, "READONLY")
|
|
field(EGU, "mbar")
|
|
field(PREC, "-5")
|
|
field(CALC, "A/1e9")
|
|
field(INPA, "$(DEVICE):CONTROL-VACUUM-MAX")
|
|
}
|
|
|
|
record(calc, "$(DEVICE):CONTROL-VACUUM-DYN-PLOT") {
|
|
field(DESC, "Stop injection at this vacuum pressure")
|
|
field(ASG, "READONLY")
|
|
field(EGU, "mbar")
|
|
field(PREC, "-5")
|
|
field(CALC, "A/1e9")
|
|
field(INPA, "$(DEVICE):CONTROL-VACUUM-DYN")
|
|
}
|
|
|
|
record(calc, "$(DEVICE):CONTROL-VACUUM-MIN-PLOT") {
|
|
field(DESC, "Stop injection at this vacuum pressure")
|
|
field(ASG, "READONLY")
|
|
field(EGU, "mbar")
|
|
field(PREC, "-5")
|
|
field(CALC, "A/1e9")
|
|
field(INPA, "$(DEVICE):CONTROL-VACUUM-MIN")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-CURRENT-MAX") {
|
|
field(DESC, "Stop injection at this current")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "mA")
|
|
field(VAL, "403")
|
|
field(PREC, "3")
|
|
field(PINI, "YES")
|
|
field(DRVH, "425")
|
|
field(DRVL, "0")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-CURRENT-MIN") {
|
|
field(DESC, "Start injection at this current")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "mA")
|
|
field(VAL, "400")
|
|
field(PREC, "3")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-TIME-MAX") {
|
|
field(DESC, "Stop injection after this time")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "s")
|
|
field(VAL, "30")
|
|
field(PREC, "3")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-TIME-MIN") {
|
|
field(DESC, "Start injection after this time")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "s")
|
|
field(VAL, "300")
|
|
field(PREC, "3")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):MBFBY-GAIN-SP") {
|
|
field(DESC, "MBFBy Gain SP for scrubbing")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "%")
|
|
field(VAL, "1")
|
|
field(PREC, "3")
|
|
field(PINI, "YES")
|
|
field(DRVH, "100")
|
|
field(DRVL, "0")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):MBFBX-GAIN-SP") {
|
|
field(DESC, "MBFBx Gain SP for scrubbing")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "%")
|
|
field(VAL, "1")
|
|
field(PREC, "3")
|
|
field(PINI, "YES")
|
|
field(DRVH, "100")
|
|
field(DRVL, "0")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-GUNGRID-ACCUM") {
|
|
field(DESC, "Gungrid val for accumulation")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "V")
|
|
field(VAL, "100")
|
|
field(PREC, "3")
|
|
field(PINI, "YES")
|
|
field(DRVH, "180")
|
|
field(DRVL, "40")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):CONTROL-GUNGRID-FPFB") {
|
|
field(DESC, "Gungrid val for FPFB Injection")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "V")
|
|
field(VAL, "160")
|
|
field(PREC, "3")
|
|
field(PINI, "YES")
|
|
field(DRVH, "180")
|
|
field(DRVL, "40")
|
|
}
|
|
|
|
# HLA Service Output/Result Parameters
|
|
|
|
record(ao, "$(DEVICE):TOPUP-TAU") {
|
|
field(DESC, "Average tau since last top up")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "h")
|
|
field(VAL, "100")
|
|
field(PREC, "3")
|
|
field(VAL, "-1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):TOPUP-DELTAT") {
|
|
field(DESC, "Time since last top up")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "min")
|
|
field(VAL, "100")
|
|
field(PREC, "3")
|
|
field(VAL, "-1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):TOPUP-DELTAI") {
|
|
field(DESC, "Current change since last top up")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "mA")
|
|
field(VAL, "100")
|
|
field(PREC, "3")
|
|
field(VAL, "-1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-BOIN-SP") {
|
|
field(DESC, "Warmup cycles for booster injection")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "15")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-BOMB-SP") {
|
|
field(DESC, "Warmup cycles for ABOMA-B")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "5")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-BOME-SP") {
|
|
field(DESC, "Warmup cycles for ABOMA-ELSE")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "15")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-BOEX-SP") {
|
|
field(DESC, "Warmup cycles for booster extraction")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "15")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-SRIN-SP") {
|
|
field(DESC, "Warmup cycles for SR Injection")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "15")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-BOIN-RB") {
|
|
field(DESC, "Warmup cycles for booster injection")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "15")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-BOMB-RB") {
|
|
field(DESC, "Warmup cycles for ABOMA-B")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "5")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-BOME-RB") {
|
|
field(DESC, "Warmup cycles for ABOMA-ELSE")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "15")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-BOEX-RB") {
|
|
field(DESC, "Warmup cycles for booster extraction")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "15")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
}
|
|
|
|
record(ao, "$(DEVICE):WARMUPCYCLES-SRIN-RB") {
|
|
field(DESC, "Warmup cycles for SR Injection")
|
|
field(ASG, "PROTECTED")
|
|
field(EGU, "")
|
|
field(VAL, "15")
|
|
field(PREC, "1")
|
|
field(PINI, "YES")
|
|
} |