from slic.utils.hastyepics import get_pv as PV
from slic.core.device.basedevice import BaseDevice
from slic.core.adjustable import PVAdjustable
from slic.utils import typename
CTA_sequence_start_PID = PV("SAR-CCTA-ESC:seq0Ctrl-StartedAt-O")
class PP_Shutter:
"""Pulsed magnet instrument classs"""
def __init__(self, ID, name="Pulsed Magnet Instrument"):
self.ID = ID
self.name = name or ID
pvname_setvalue = ID
pvname_readback = ID
self._adj = PVAdjustable(pvname_setvalue, pvname_readback, accuracy=0, internal=True)
def close(self):
self._adj.set_target_value(0).wait()
def open(self):
self._adj.set_target_value(1).wait()
@property
def status(self):
state = self._adj.get_current_value()
if state is None:
return "not connected"
return "open" if state else "closed"
def __repr__(self):
tn = typename(self)
return f'{tn} "{self.name}" is {self.status}'
def get_Cernox_temperature():
""" Very improvised """
import csv
fname = '/gfa/.mounts/sf_cristallina/applications/devices/CryovacTIC/temperatures_009.csv'
with open(fname) as f:
reader = csv.reader(f)
rows = [row for row in reader]
return float(rows[-1][3])