define(PLC_Homing='1')
//Homing:
//Move all motors left bottom
//move 1mm up
//move both mottors at same time
//move to limit switch, gather data, move to other limit switch, gather stop. move back to first limit switch
//motID :P0 : Motor Number
//direction :P1 : Motion direction to first limit switch: -1 -> #1j- ,+1 -> #1j+
//status :P100: local status
//timer :P101: local timer
open plc PLC_Homing
define(motID='L0',direction='P1',status='P100',timer='P101')
jog-1; jog-2; jog-3; jog-4;
Motor[1].HomeVel=0.5
Motor[2].HomeVel=0.5
Motor[3].HomeVel=0.5
Motor[4].HomeVel=0.5
status=10
while(1)
{
if((Motor[1].MinusLimit==1 || Motor[1].FeFatal==1)){
if((Motor[2].MinusLimit==1 || Motor[2].FeFatal==1)){
if((Motor[3].MinusLimit==1 || Motor[3].FeFatal==1)){
if((Motor[4].MinusLimit==1 || Motor[4].FeFatal==1)){
status=11
break
}}}}
}
timer = Sys.RunTime + 2
status=100
while (Sys.RunTime < timer){} //wait 2 sec
status=101
jog1:1000; jog2:1000; jog3:1000; jog4:1000;
timer = Sys.RunTime + 2
status=200
while (Sys.RunTime < timer){} //wait 2 sec
status=201
while(1)
{
if(Motor[1].DesVelZero==1 && Motor[2].DesVelZero==1 && Motor[3].DesVelZero==1 && Motor[4].DesVelZero==1)
{
status=12
break
}
}
timer = Sys.RunTime + 2
while (Sys.RunTime < timer){}
home 1; home 2; home 3; home 4
status=13
while(1) //wait homing index found done
{
if(Motor[1].HomeComplete==1 && Motor[2].HomeComplete==1 && Motor[3].HomeComplete==1 && Motor[4].HomeComplete==1)
{
status=14
break
}
}
while(1) //wait moving to zero position done
{
if(Motor[1].DesVelZero==1 && Motor[2].DesVelZero==1 && Motor[3].DesVelZero==1 && Motor[4].DesVelZero==1)
{
status=15
break
}
}
disable plc PLC_Homing
close