same devices with "direct PWM" (idCmd=0, iqCmd controls torque)

Test Servo, Stage X Parker MX80L, Stage Y Parker MX80L, LS Mecapion rotationstage
This commit is contained in:
2016-12-15 16:31:31 +01:00
parent 5b4848f6dc
commit 87168508e6
4 changed files with 212 additions and 61 deletions

View File

@@ -29,13 +29,27 @@ http://www.inmoco.co.uk/Upload/product/1037_DD_Series_Motors_79.pdf
- Max Current 4.38 Arms
- 32 pole (16 einraster per rev)
Servo Test Motor QBL
--------------------
- 8 pole (4 einraster per rev)
Servo Test Motor QBL 4208-41-04-006
-----------------------------------
8 pole (4 lock position per rev)
24 V rated voltage
1.79 A rated phase current
5.4 A max peak current
4000 rpm rated speed
1.8 ohm line to line resistance
2.6 mH line to line inductance
2Phase Stepper Test Motor Vextra PK244M
---------------------------------------
- 200 pole (100 einraster per rev)
************************
copy configuration after 'save':
scp -r root@SAROP11-CPPM-MOT6871:/opt/ppmac/usrflash /scratch
restore
scp -r /scratch/usrflash.IDE/* root@SAROP11-CPPM-MOT6871:/opt/ppmac/usrflash
$$$
#4$