towards recabeling and reconfiguring all Powerbricks and Smaracts devices
Here all IOCs were started without any hardware. So in the next steps the hardware must be tested.
This commit is contained in:
71
cfg/old/init_limit.cfg
Normal file
71
cfg/old/init_limit.cfg
Normal file
@@ -0,0 +1,71 @@
|
||||
//home by bove to physical limits and set these to -5000um
|
||||
|
||||
define(PLC_Homing='1')
|
||||
|
||||
open plc PLC_Homing
|
||||
define(status='P100',timer='P101')
|
||||
|
||||
L20=Motor[2].MaxDac
|
||||
Motor[2].MaxDac=500
|
||||
L21=Motor[2].FatalFeLimit
|
||||
Motor[2].FatalFeLimit=2000
|
||||
L22=Motor[2].JogSpeed
|
||||
Motor[2].JogSpeed=1
|
||||
|
||||
L30=Motor[3].MaxDac
|
||||
Motor[3].MaxDac=500
|
||||
L31=Motor[3].FatalFeLimit
|
||||
Motor[3].FatalFeLimit=2000
|
||||
L32=Motor[3].JogSpeed
|
||||
Motor[3].JogSpeed=1
|
||||
|
||||
|
||||
Motor[2].PhaseFindingStep=1
|
||||
Motor[3].PhaseFindingStep=1
|
||||
timer = Sys.RunTime + 1;while (Sys.RunTime < timer){} //wait 1 sec
|
||||
|
||||
jog-2; jog-3;
|
||||
|
||||
status=1
|
||||
while(1)
|
||||
{
|
||||
if(Motor[2].FeWarn==1 && (status&2)==0)
|
||||
{
|
||||
status=status|2
|
||||
jog/2
|
||||
Motor[2].PhasePos=310
|
||||
Motor[2].HomePos=Motor[2].ActPos+5000
|
||||
jog2=0
|
||||
}
|
||||
if(Motor[3].FeWarn==1 && (status&4)==0)
|
||||
{
|
||||
status=status|4
|
||||
jog/3
|
||||
Motor[3].PhasePos=1210
|
||||
Motor[3].HomePos=Motor[3].ActPos+5000
|
||||
jog3=0
|
||||
}
|
||||
if(status==7)
|
||||
{
|
||||
status=status|8
|
||||
break
|
||||
}
|
||||
}
|
||||
|
||||
timer = Sys.RunTime + 2
|
||||
while (Sys.RunTime < timer){} //wait 2 sec
|
||||
status=100
|
||||
timer = Sys.RunTime + 2
|
||||
status=200
|
||||
while (Sys.RunTime < timer){} //wait 2 sec
|
||||
status=201
|
||||
|
||||
Motor[2].MaxDac=L20
|
||||
Motor[2].FatalFeLimit=L21
|
||||
Motor[2].JogSpeed=L22
|
||||
Motor[3].MaxDac=L30
|
||||
Motor[3].FatalFeLimit=L31
|
||||
Motor[3].JogSpeed=L32
|
||||
|
||||
disable plc PLC_Homing
|
||||
close
|
||||
Reference in New Issue