towards recabeling and reconfiguring all Powerbricks and Smaracts devices
Here all IOCs were started without any hardware. So in the next steps the hardware must be tested.
This commit is contained in:
22
cfg/MX3_setup.cfg
Normal file
22
cfg/MX3_setup.cfg
Normal file
@@ -0,0 +1,22 @@
|
||||
//5 simulated cam movers
|
||||
|
||||
|
||||
!encoder_sim(enc=1,tbl=1,mot=1)
|
||||
!motor(mot=1,dirCur=0,contCur=100,peakCur=100,timeAtPeak=1,JogSpeed=8.,numPhase=3,invDir=True)
|
||||
Motor[1].pLimits=0;Motor[1].AmpFaultLevel=0;Motor[1].pAmpEnable=0;Motor[1].pAmpFault=0
|
||||
|
||||
!encoder_sim(enc=2,tbl=2,mot=2)
|
||||
!motor(mot=2,dirCur=0,contCur=100,peakCur=1000,timeAtPeak=1,JogSpeed=8.,numPhase=3,invDir=True)
|
||||
Motor[2].pLimits=0;Motor[2].AmpFaultLevel=0;Motor[2].pAmpEnable=0;Motor[2].pAmpFault=0
|
||||
|
||||
!encoder_sim(enc=3,tbl=3,mot=3)
|
||||
!motor(mot=3,dirCur=0,contCur=100,peakCur=1000,timeAtPeak=1,JogSpeed=8.,numPhase=3,invDir=True)
|
||||
Motor[3].pLimits=0;Motor[3].AmpFaultLevel=0;Motor[3].pAmpEnable=0;Motor[3].pAmpFault=0
|
||||
|
||||
!encoder_sim(enc=4,tbl=4,mot=4)
|
||||
!motor(mot=4,dirCur=0,contCur=100,peakCur=1000,timeAtPeak=1,JogSpeed=8.,numPhase=3,invDir=True)
|
||||
Motor[4].pLimits=0;Motor[4].AmpFaultLevel=0;Motor[4].pAmpEnable=0;Motor[4].pAmpFault=0
|
||||
|
||||
!encoder_sim(enc=5,tbl=5,mot=5)
|
||||
!motor(mot=5,dirCur=0,contCur=100,peakCur=1000,timeAtPeak=1,JogSpeed=8.,numPhase=3,invDir=True)
|
||||
Motor[5].pLimits=0;Motor[5].AmpFaultLevel=0;Motor[5].pAmpEnable=0;Motor[5].pAmpFault=0
|
||||
Reference in New Issue