Files
muSRFlow/docs/source/troubleshooting.rst
T
salman 01df50c3ac Clarify installation guides and retire obsolete CGI parity references
Put Windows and Linux setup, upgrades, and troubleshooting in dedicated manual chapters linked directly from the README. Separate user installation from maintainer packaging instructions and refresh generated HTML/PDF manuals.

Remove stale checklist references and completed legacy gap descriptions while preserving relevant future workflow improvements and historical release notes.
2026-10-28 17:22:53 +01:00

3.8 KiB

Troubleshooting

For Windows setup, WSL startup errors, missing ROOT libraries, and older runtime updates, see install-windows. For Linux package/runtime setup, see install-linux. The sections below cover analysis workflows.

Fit or plot will not start

Check the resolution warning under the run row: it reports runs that cannot be resolved against the current data tree. In the browser edition, confirm the server exposes those runs; on the desktop, verify the data directory preference points at the real data root. If a model has no valid run, the action reports the reason in the outcome dialog and the run log.

"Nothing to fit"

An independent-series fit (two or more data sets, no shared parameters) where every run is set to skip reports this instead of running. Set at least one chip to reuse or refit, or use Refit all from the All dropdown.

Fitted parameters look wrong or unchanged

  • The parameter table is the source of the starting values. After a fit it holds the fitted results; run the fit again after editing values.
  • Hand-edited MSR documents are authoritative: if the editor lock is closed, Fit and Plot use the editor text and ignore GUI changes until you unlock (see msr-editor).
  • A model change rebuilds the parameter table and may reset values; re-check the rows for every component you use.

Parameter plot is empty or missing data

  • Click Refresh after a new fit -- panels reread the parameter file.
  • Use Data... to change the data set of the active panel.
  • A panel that shares the X axis with no plottable column shows its empty message; activate it and add a parameter or load another file.
  • Overlaid files that lack the panel's X column (or could not be re-read) are skipped and listed in a striped note under the panel. Fix the X column (X control) or uncheck the file under Plot options > Overlay data sets.

Parameter plot hangs on "Preparing plot files"

"Preparing plot files" covers the setup performed before the tools run. If the step never finishes, check the server/work-bench side:

  • The command-line tools must be reachable on the machine that runs them (local install on the desktop, server-side install for the CGI).
  • On the desktop, confirm the work directory is writable.

The command log records every command line that was attempted; it is the first place to look.

Web page cannot load data

The browser edition fetches data and runs fits on the server. If the page loads but actions fail, verify the CGI endpoint is reachable (see cgi/README.md) and that the server data root matches what the page was deployed with. The server health endpoint reports the configured data root; muSRFlow's resolution warning should agree with it.

Restored configuration differs from the original machine

Configuration links carry analysis settings only, not data or working directories. On a different machine the same settings resolve against that machine's data tree. If runs do not resolve, fix the data/startup-XML configuration (desktop Preferences; server configuration on the web) and refit.

muSRFlow shares both a compact compressed form (#c=) and a readable legacy form (#cfg=). Both are accepted by the web and the desktop restore dialog.

Reporting problems

Include the command log (open from the status bar or the outcome dialog) and the versions involved. Contact Zaher Salman zaher.salman@psi.ch with those details for the fastest help.