Overview

muSRFlow provides a modern interface over the classic µSR analysis tools. A typical session selects the data, chooses a fit model, fits it, inspects the result, and finally inspects how the fitted parameters vary run by run.

What you get

  • A single window with the full workflow in tabs:
    • Runs -- run selection, factorial fit range, fit model, fit options, and the Plot / FFT / RRF view settings.
    • Parameters -- the parameter table with starting values, steps, limits, and plot selection.
    • Constraints -- custom parameters and parameter constraints.
    • t0 / Bg -- expert timing and background controls.
    • MSR Editor -- the generated MSR document, with GUI-to-MSR and MSR-to-GUI synchronisation.
    • Results -- generated files, execution details, and the full command log.
  • Two one-click workflow actions in the main toolbar:
    • Fit -- generate the MSR document and run the fit.
    • Plot -- generate the MSR document and display the spectra.
  • Interactive parameter plots that show how every fitted parameter evolves across the selected runs.
  • Configuration sharing: the current analysis settings can be encoded into a link and restored on another machine.

Under the hood

muSRFlow does not reimplement the physics. It writes MSR files that are fed to the musrfit package, and renders spectra with musrview:

  • musrfit -- the muon-spectroscopy fitting engine. muSRFlow generates an MSR file from the GUI and runs musrfit on it. The fitted values (a par.dat parameter table) feed the parameter plots.
  • musrview -- the reference data viewer. On the desktop it opens its own native window; in the browser edition the server produces a ROOT canvas that is drawn with JSROOT inside the page.
  • msr2data -- converts a fitted MSR file into a parameter table (par.dat) that the parameter plot can read.
  • dump_header -- reads run metadata used to resolve portable run names and to guess initial parameters.

Two editions

  • Desktop (Electron) runs the tools directly on your machine, manages its own data and working directories (set under File / Preferences), and can open and save MSR files from the File menu.
  • Web runs the same interface in a browser. The data tree and the command-line tools live on the server, so file selection is limited to what the server exposes, and there is no local Preferences dialog.

Both editions share the same workflow and produce the same MSR documents. The differences that matter day to day are collected in platforms.

A first fit

  1. In the Runs tab, choose the instrument and year and enter one or more run numbers.
  2. Adjust the fit range and the fit model as needed.
  3. Press Fit.
  4. Open the Parameters tab to verify and adjust starting values, then press Fit again.
  5. Use Plot any time to look at the spectra.
  6. Select parameters and choose Plot parameters... to inspect how they vary across the run set (see parameters-plots).

The Quick Start button (?) at the right of the tab bar opens a short guide that highlights the section relevant to the active tab. Its sections are expanded into the chapters of this manual.