TEST = False
if TEST:
set_exec_pars(path="/sls/X12SA/data/x12saop/Data10/bpm/{date}_{time}_{name}")
#rel_x = pico_bpm6_new_x.read()
rel_x = pico_bpm6_ts_x.read()
class SensorXAxis(ReadableArray):
def __init__(self, sensor):
self.sensor = sensor
self.x = rel_x[:]
def read(self):
timestamp = self.sensor.getTimestamp()
return [x + timestamp for x in self.x]
def getSize(self):
return len(self.x) #only reads if cache is None
def fixed_samples_scan(sensor, samples):
x_axis = SensorXAxis(sensor)
set_device_alias(x_axis, sensor.name+"_x_axis")
r = mscan(sensor, [sensor, x_axis], samples, title = sensor.name)
set_attribute( r.group, "Sensor", sensor.channelName)
set_attribute( r.group, "Scan Type", "Fixed samples: " + str(samples))
def fixed_time_scan(sensor, time):
x_axis = SensorXAxis(sensor)
set_device_alias(x_axis, sensor.name+"_x_axis")
r = mscan(sensor, [sensor, x_axis], -1, time)
set_attribute( r.group, "Sensor", sensor.channelName)
set_attribute( r.group, "Scan Type", "Fixed time: " + str(time))
def time_interval_scan(sensor, samples, interval):
x_axis = SensorXAxis(sensor)
set_device_alias(x_axis, sensor.name+"_x_axis")
r = tscan([sensor, x_axis], samples, interval)
set_attribute( r.group, "Sensor", sensor.channelName)
set_attribute( r.group, "Scan Type", "Time interval samples: " + str(samples) + " interval:" + str(interval))
sensors = [pico_bpm6_ts_sumall, pico_bpm6_ts_cur1, pico_bpm6_ts_cur2, pico_bpm6_ts_cur3, pico_bpm6_ts_cur4]
setup_plotting(line_plots = sensors, plot_list =sensors )
caputq ("X12SA-OP-BPM6:TS:TSAcquire", 1)
for sensor in sensors: sensor.setMonitored(True)
caput ("X12SA-ES1-TTL:OUT_02", "HIGH")
try:
time_interval_scan(pico_bpm6_ts_sumall, 10, 0.2)
samples = 10
parallelize([fixed_samples_scan, [pico_bpm6_ts_sumall, samples]], [fixed_samples_scan, [pico_bpm6_ts_cur1, samples]], \
[fixed_samples_scan, [pico_bpm6_ts_cur2, samples]], [fixed_samples_scan, [pico_bpm6_ts_cur3, samples]], \
[fixed_samples_scan, [pico_bpm6_ts_cur4, samples]])
time = 1.00
parallelize([fixed_time_scan, [pico_bpm6_ts_sumall, time]], [fixed_time_scan, [pico_bpm6_ts_cur1, time]], \
[fixed_time_scan, [pico_bpm6_ts_cur2, time]], [fixed_time_scan, [pico_bpm6_ts_cur3, time]], \
[fixed_time_scan, [pico_bpm6_ts_cur4, time]])
finally:
for sensor in sensors: sensor.setMonitored(False)
caput ("X12SA-ES1-TTL:OUT_02", "LOW")
caputq ("X12SA-OP-BPM6:TS:TSAcquire", 0)