#Parameters
B1 = 10 # starting mag. field in Amps
B2 = -B1 # final mag. field in Amps
T1=150 # starting temperature in K
T2=200 # final temperature in K
TSTEP=10 # Temperature step size
ENERGIES = (708.5,705) #list of energies in eV
OFFSET1 = -9 #ID1 offset
OFFSET2 = -8 #ID2 offset
FIELD_PRECISION = 0.05 # in Amps
ENERGY_CHANGE_SLEEP = 0.1 # put the Enerrgy settling time if needed
FIELD_CHANGE_SLEEP = 0.1 # put the Field settling time if needed
TEMP_CHANGE_SLEEP = 10.0 # put the Temperature settling time if needed
ACC_TIME = 150.0 # accumulation time s
# List of scans.
STEPS =frange(T1, T2, TSTEP, True)
#Pre-actions
# Here offsets are set
caput ("X11PHS-E:OPT","PGM+ID2")
#caput(OTF_OFF1,-50) #detune ID1
caput(OTF_OFF2,OFFSET2)
wait_channel(OTF_DONE, 1, type = 'i')
#cawait("X11MA-PHS:ALL-DONE",1.0)
wait_channel(OTF_DONE, 1, type = 'i')
# setting number of samples to be averaged, which depends on the accumulation time
avg = ACC_TIME * 10
caputq("X11MA-ES1-10ADC:AVG",avg)
# plot properties
set_preference(Preference.ENABLED_PLOTS, ['field', 'tey_norm'])
set_preference(Preference.PLOT_TYPES, {'tey_norm':1})
#scan = ManualScan(['field', 'Energy'], ['TEY', 'I0', 'polarization', 'temperature', 'RingCurrent', 'tey_norm'] , [min(setpoints), min(ENERGIES)], [max(setpoints), max(ENERGIES)], [len(setpoints)-1, len(ENERGIES)-1])
scan = ManualScan(['field', 'Energy','Temperature'], ['I0', 'TEY', 'TFY', 'polarization', 'temperature', 'RingCurrent', 'tey_norm','tfy_norm'] , [min([B1,B2]), min(ENERGIES),min(STEPS)], [max([B1,B2]), max(ENERGIES),max(STEPS)], [1, len(ENERGIES)-1, len(STEPS)-1])
scan.start()
# Main loop
for T in STEPS:
# set Temperature
caputq(OTF_MODE2,1) # already set the polarization
caput("X11MA-XMCD:I-SETraw",B1)# warm in B1
caput('X11MA-ES3-LSCI:TEMP.VAL',T)
# while not caget('X11MA-ES3-LSCI:TEMP-STAT'):
#time.sleep(5)
time.sleep( TEMP_CHANGE_SLEEP ) # Settling time
#Mode loop:
for MODE in [1,2]: #polarization (CIRC+ -> 1 or CIRC- -> 2)
caput(OTF_MODE2,MODE)
#Field loop
for B in [B1,B2]:
print "Setting field = ", B
caput("X11MA-XMCD:I-SETraw",B)
time.sleep( FIELD_CHANGE_SLEEP ) # Settling time
readback1 = caget("X11MA-XMCD:Ireadout")
while abs(readback1-B) > FIELD_PRECISION:
readback1 = caget("X11MA-XMCD:Ireadout")
time.sleep(0.5)
for E in ENERGIES:
print "Setting energy = ", E
caput(OTF_ESET, E)
wait_channel(OTF_DONE, 1, type = 'i')
readback2 = energy.read()
if abs(readback2 - E) > 0.1 : # TODO: Check accuracy
raise Exception('Energy could not be set to the value ' + str(E))
sleep( ENERGY_CHANGE_SLEEP ) # Settling time
caput("X11MA-ES1-10ADC:TRG.PROC",1) # accumulate
time.sleep( 0.1) # wait a bit more
detector1 = keithley_1a.read() #Keithley1
detector2 = keithley_2a.read() #Keithley2
detector3 = keithley_3a.read() #Keithley3
detector4 = caget(OTF_MODE2) #polarization in ID2
#detector5 = caget("X11MA-ID2:ALPHA-READ") # polAngle in ID2
detector6 = caget('X11MA-ES3-LSCI:TEMP_RBV') #temperature.get()
detector7 = caget("ARIDI-PCT:CURRENT")
#detector8 = signal_field_analog_x.read() # fieldAnalogX.get()
tey_norm = detector2/detector1
tfy_norm = detector3/detector1
#converting polarization strings to integer numbers: C+ -> 1 and C- -> 2
if detector4 == 'CIRC +': detector4 = 1
elif detector4 == 'CIRC -': detector4 = 2
else: detector4 = 0
readback3=caget('X11MA-ES3-LSCI:TEMP_RBV') # read temperature
#scan.append ([B, E], [readback1, readback2], [detector1, detector2, detector4, detector6, detector7, tey_norm])
scan.append ([B, E, T], [readback1, readback2, readback3], [detector1, detector2, detector3, detector4, detector6, detector7, tey_norm, tfy_norm])
scan.end()
caput("X11MA-ES1-10ADC:AVG",1)
print "Wake up its done"
print("Success")