file_prefix = time.strftime("%Y%m%d") # CHANGE THE PATH IN THE OTH input_path = "/sls/X11MA/data/X11MA/Data1/public/scans/1809_Armin/" #input_path = "/sls/X11MA/data/X11MA/slsbl/x11ma/e17174/Data1/Aug_2018/sample02-LMNO_pristine/" output_path = input_path #Parameters E1 = sys.argv[0] E2 = sys.argv[1] TIME = sys.argv[2] DELAY = sys.argv[3] number_of_scans = 1 ID1=0 ID2=1 OFFSET1 = -2.0 #eV OFFSET2 = -2.9 #eV PREFIX = 'Data' RUNTYPE = "LH" ROUNDS = 1 PLOT_TYPE = 1 print "\nStarting energy scan - Parameters: ", print E1,E2,TIME,DELAY,OFFSET1,OFFSET2,RUNTYPE#,ALPHA1,ALPHA2 caput(OTF_ESET, E1) ############################################################################### # Plotting ############################################################################### task = None running = False def _startPlot(type): global running sep = "\t" line_sep = "\r\n" print "Starting plot: type " + str(type) running = True p = plot(None,name="Energy")[0] s = p.getSeries(0) cur = 0 time.sleep(3.0) t_start = time.time() t_end = time.time() + TIME*60.0 while running: try: #if otf_start.read() == 0: if (otf_start.read() == 0 or time.time() > t_end): break e = energy.read() if (abs(e-cur)) > 0.1: v = abs((keithley_3a.read() / ((keithley_1a if (type==1) else keithley_3a).read() ))) s.appendData(e,v) cur = e # time.sleep(0.2) except: pass print "Done Plotting" def startPlot(type = 1): global task task = fork((_startPlot,(type,)),) def stopPlot(): global task, running running = False ret = join(task) ############################PGM+ID1+ID2################################################### def switchpol(activeID, runtype): global pol_str if activeID == 1: caput(OTF_OFF1,OFFSET1) caput(OTF_OFF2,OFFSET2-40) #detune ID2 if runtype in ["+/-", "+"]: pol_str = "circ +" elif runtype in ["LH/LV", "LH"]: pol_str = "Lin. Horizontal" elif activeID == 2: caput(OTF_OFF1,OFFSET1-40) #detune ID1 caput(OTF_OFF2,OFFSET2) if runtype in ["+/-", "-"]: pol_str = "circ -" elif runtype in ["LH/LV", "LV"]: pol_str = "Lin. Vertical" else: raise Exception("Invalid parameter") mag_str = None #mag_str = caget(MAG) pol_str = None polswitch = 1 fid = get_next_fid(input_path, "o" + file_prefix) ############################################################################### #Prepare scan ############################################################################### """ if ID1 == 1: caput ("X11PHS-E:OPT","PGM+ID1") elif ID2 == 1: caput ("X11PHS-E:OPT","PGM+ID2") else: caput ("X11PHS-E:OPT","PGM+ID1+ID2") if RUNTYPE in ["+/-", "+", "-"]: caput(OTF_MODE1,1) # circ + in ID1 caput(OTF_MODE2,2) # circ - in ID2 wait_channel(OTF_DONE, 1, type = 'i') if RUNTYPE == "+/-": number_of_scans = 2 * ROUNDS else: number_of_scans = ROUNDS elif RUNTYPE in ["LH/LV", "LH", "LV"]: caput(OTF_MODE1,0) caput(OTF_MODE2,0) wait_channel(OTF_DONE, 1, type = 'i') caput(OTF_ALPHA1, 0.0) # LH in ID1 caput(OTF_ALPHA2, 90.0) # LV in ID2 wait_channel(OTF_DONE, 1, type = 'i') if RUNTYPE == "LH/LV": number_of_scans = 2 * ROUNDS else: number_of_scans = ROUNDS else: raise Exception("Invalid run type: " + RUNTYPE) if RUNTYPE in ["-", "LV"]: switchpol(2, RUNTYPE) # tune ID2 --> polarization: C- or LV polswitch = 0 elif RUNTYPE in ["+/-", "+", "LH/LV", "LH"]: switchpol(1, RUNTYPE) # tune ID1 --> polarization: C+ or LH time.sleep(1.0) wait_channel(OTF_DONE, 1, type = 'i') """ open_vg10() time.sleep(0.5) open_vg11() time.sleep(0.5) open_vg12() time.sleep(0.5) open_vg13() for scan_no in range(number_of_scans): suffix = ("%03d" % fid) input_file = input_path + "o" + file_prefix + "_" + suffix + ".dat" # Log.append(scan_no+1) #Log.append(posX) sep = "\t" line_sep = "\r\n" caput(OTF_E1, E1) caput(OTF_E2, E2) caput(OTF_TIME, TIME) caput(OTF_FTS,file_prefix) caput(OTF_FID,fid) time.sleep(2.0) caput(OTF_ESET, E1) wait_channel(OTF_DONE, 1, type = 'i') time.sleep(DELAY) time.sleep(2.0) T_start = Temp.getValue() startPlot(PLOT_TYPE) #Start the OTF scan #caput(OTF_START, 'GO') otf_start.write(1) time.sleep(3.0) print "Running scan " + str(scan_no+1) + " out of " + str(number_of_scans) try: #wait_channel(OTF_START, 'STOP', timeout = int(TIME*60), type = 's') otf_start.waitValue(0, (15 + int(TIME*60)) *1000) except: print "******** OTF STOP TIMEOUT **********" otf_start.write(0) finally: stopPlot() # caput(OTF_ESET, E1) T_end = Temp.getValue() time.sleep(5.0) #Convert file output_file = output_path + "os" + file_prefix + "_" + suffix + ".dat" print("Converting data file: " + output_file); convert_file(input_file, output_file) plot_file(output_file, file_prefix+"_" + suffix) #"Scan " + str(scan_no+1)) print "Finished scan " + str(scan_no+1) + " out of " + str(number_of_scans) time.sleep(3.0) fid = fid + 1 #caput(OTF_ESET, E1) #close_vg13() print "Finished Energy scan" print("Success")