#Parameters
E1 = 630
E2 = 685
TIME = 1 #min
DELAY = 0.0 #s
MODE = 'LINEAR' #'CIRC +'
OFFSET = None
FOLDER = '2021_03/20210330'
FILE = 'Test'
ALPHA=0 #None
'''
set_exec_pars (reset=True)
print "wait 0.5 seconds..."
time.sleep(0.5) # delay to avoid immediate commands to ID after completion of last scan
#print "\nCheck temperature"
#wait_temp()
#print "\nTemperature ok"
print "\nStart energy scan..."
#print E1,E2,TIME,DELAY,str(MODE) ,str(OFFSET) ,str(FOLDER) ,str(FILE) ,str(ALPHA)
if MODE == "LINEAR":
print E1,"eV ->",E2,"eV,",TIME,"min duration,",DELAY,"sec delay,",str(MODE),str(ALPHA),"deg"
else:
print E1,"eV ->",E2,"eV,",TIME,"min duration,",DELAY,"sec delay,",str(MODE)
folder = os.path.expanduser("~/Data1/") + FOLDER + "/";
set_exec_pars(name= FILE)
#Pre-actions
if NO_BEAM_CHECK == False:
print "Wait beam"
wait_beam()
if MODE is not None:
print "Set polarization"
pol_mode.write(MODE)
if MODE == 'LINEAR':
if ALPHA is not None:
pol_angle.write(ALPHA)
wait_pol_done(1.0) # new script to wait for polarization. Wait_device does not work for this channel
print "Set Energy"
if OFFSET is not None:
pol_offset.write(OFFSET) #TODO: CAPUT
#time.sleep(0.5)
#wait_device(pol_done, "DONE")
energy.write(float(E1)) # no need to add wait command. This commands sets and waits.
print "Energy setting done"
caput('X07MA-PGM:CERBK.N',10) # set energy readback averaging to 10 pts
caput('E1', E1)
caput('E2', E2)
caput('TIME', TIME)
#caput('FOLDER', FOLDER)
caput('FOLDER', "OTF/" + FOLDER)
caput('FILE', FILE)
time.sleep(0.1)
#open_valve()
#open_valve(0.0) #TODO: WHY WRITING AGAIN???
time.sleep(DELAY)
#if WAIT_STABLE_TEMPERATURE == True:
# wait_temp()
topup_thresh=402.1
print('wait for topup')
while(caget('ARIDI-PCT:CURRENT') < topup_thresh):
sleep(0.3)
pass;
print('topup done')
scan_completed = False
try:
while True: # if ABORT_ON_ID_ERROR == False, waits reading with no ID error
caput('START', '1')
write_logs()
waiting = True
class Time(Readable):
def __init__(self):
self.start = time.time()
def read(self):
return time.time()-self.start
class NORMtey(Readable):
def read(self):
return float(CADC1.take())/float(CADC2.take())
class NORMdiode(Readable):
def read(self):
return float(CADC3.take())/float(CADC2.take())
pol = pol_angle if (pol_mode.readback.read() == "LINEAR") else pol_mode #Fixed, should be an attribute, not a column
sensors = [Ecrbk, CADC1, CADC2, CADC3,CADC4,CADC5,current,Time(),FieldX,FieldZ,pol, Temperature, NORMtey(), NORMdiode()]
def monitoring_task():
global scan_completed
time.sleep(1.0)
try:
plot_titles = ["TEY raw", "I0", "diode_raw", "TEY_norm", "diode_norm"]
for index, title in enumerate(plot_titles, start=0): get_plots()[index].title = title
except:
pass
wait_channel('START', 'STOP', type = 's')
scan_completed = True
get_exec_pars().currentScan.abort()
ret = fork(monitoring_task)
current.alias="MCurr"
pol.alias="Pol"
print "Scanning...",
try:
mscan(Ecrbk, sensors, -1, None, range="auto", domain_axis="Ecrbk", enabled_plots = ["NORMtey", "NORMdiode", CADC1,CADC3, CADC2], )
finally:
ret[0].cancel(True)
current.alias=None
pol.alias=None
#time.sleep(2.0)
print "Finished Energy scan."
if after_sample(): #Repeat if id error
break
except:
if not scan_completed:
print sys.exc_info()
print("Aborting...")
while caget('START') == 'START':
caput('START', '0')
time.sleep(0.1)
#if get_exec_pars().source != CommandSource.plugin:
# show_message(str(ex))
raise