#Script imported from: MgE_plus.xml #Parameters """ E1 = 1290 E2 = 1450 TIME = 3 #min DELAY = 10.0 #s MODE = 'CIRC +' FOLDER = '2015_04/20150417' FILE = 'MgE_plus' """ """ E1 = 690 E2 = 755 TIME = 3 #min DELAY = 10.0 #s MODE = 'CIRC +' FOLDER = '2015_04/20150417' FILE = 'Fe_plus' """ #Pre-actions cawait('ACOAU-ACCU:OP-MODE', 'Light Available', type = 's') caput('X07MA-ID:MODE', MODE) time.sleep(1.0) cawait('X07MA-ID:DONE', 'DONE', type = 's') caput('X07MA-ID:ENERGY-OFFS', '-9.0') cawait('X07MA-ID:DONE', 'DONE', type = 's') caput('E1', E1) caput('E2', E2) caput('TIME', TIME) caput('FOLDER', FOLDER) caputq('X07MA-PHS-E:GO.A', E1) cawait('X07MA-PHS:alldone', '1', type = 's') time.sleep(0.5) caput('FILE', FILE) time.sleep(0.1) caput('X07MA-OP-VG13:WT_SET', 'Try open') time.sleep(5.0) caput('X07MA-OP-VG13:WT_SET', 'Try open') time.sleep(DELAY) caput('START', '1') #Post-actions cawait('START', 'STOP', type = 's') time.sleep(2.0)