#Parameters """ FIELD = "Hx" START_FIELD = -0.1 END_FIELD = 0.1 ENERGIES = (707.90, 703.90) RAMP_RATE = 0.2 ENERGY_CHANGE_SLEEP = 0.5 MODE = 'CIRC +' OFFSET = -1.0 """ iPS = True FIELD_PRECISION = 0.01 if FIELD == field_z: FIELD = "Hz" field = field_z if FIELD == "Hz" else (field_x_ips if iPS else field_x ) field_done = field_z_done if FIELD == "Hz" else (None if iPS else field_x_done) ramp_rate = ramp_rate_z if FIELD == "Hz" else (ramp_rate_x_ips if iPS else ramp_rate_x) #Pre-actions #cawait('ACOAU-ACCU:OP-MODE', 'Light Available', type = 's') wait_beam() if MODE is not None: pol_mode.write(MODE) if OFFSET is not None: pol_offset.write(OFFSET) #caput('X07MA-ID:ENERGY-OFFS', OFFSET) caputq('X07MA-PC:CSCALER.INPB', '1') if RAMP_RATE is not None: ramp_rate.write(RAMP_RATE) ramp_rate.waitInPosition(RAMP_RATE,10000) if len(ENERGIES) ==2: # dif_series = plot([],"Dif", title="Dif")[0].getSeries(0) dif_series = plot([],"Dif")[0].getSeries(0) else: dif_series = None set_preference(Preference.ENABLED_PLOTS, ['field', 'tey_norm', 'trans_norm']) set_preference(Preference.PLOT_TYPES, {'tey_norm':1, 'trans_norm':1}) scan = ManualScan(['field', 'Energy'], ['TEY', 'I0', 'trans', 'polarization', 'polAngle', 'temperature', 'RingCurrent', 'fieldAnalogX', 'tey_norm','trans_norm'], [0.0, ENERGIES[0]], [0.0, ENERGIES[-1]], [0, len(ENERGIES)-1]) scan.start() print "SKIPPED Waiting for start field" if abs(field.readback.read() - START_FIELD) > FIELD_PRECISION: field.write(START_FIELD) if field_done is None: time.sleep(1.0) caput("X07MA-ES1-IPS:ACTION", 1) time.sleep(3.0) wait_device_in_range(field, START_FIELD, FIELD_PRECISION) print "Waiting field done..." while caget("X07MA-ES1-IPS:OUTPUT_RBV", "i") != 0 : time.sleep(0.1) print "Done waiting" else: time.sleep(3.0) wait_device(field_done, 1) #ramp_done.wait_for_value(1.0) wait_device(pol_done, "DONE") #open_valve(2.0) print "Set end field" field.write(END_FIELD) #caputq('X07MA-PC-PS2:M:GO.A', END_FIELD) if len (ENERGIES)==1: energy.write(setpoint2) sleep( ENERGY_CHANGE_SLEEP ) # Settling time index = 0 while(True): #Dimension 2START_FIELD = -0.2 #ArrayPositioner Energy for setpoint2 in ENERGIES: if len (ENERGIES)>1: #Energy.put(setpoint2, timeout=None) # TODO: Set appropriate timeout energy.write(setpoint2) sleep( ENERGY_CHANGE_SLEEP ) # Settling time else: sleep( 0.1 ) # TODO: Check #TODO: change to Controlled variable? readback2 = energy_readback.read() #EnergyReadback.get() if abs(readback2 - setpoint2) > 0.1 : # TODO: Check accuracy raise Exception('Energy could not be set to the value ' + str(setpoint2)) #Detector field readback field_readback = field.readback.read() #fieldReadback.get() detector1 = signal_tey.read() #TEY.get() detector2 = signal_i0.read() #I0.get() detector3 = signal_trans.read() #trans.get() detector4 = float(pol_mode.getPositions().index(pol_mode.readback.read())) #polarization.get() detector5 = pol_angle.read() #polAngle.get() detector6 = temperature.readback.read() #temperature.get() detector7 = current.read() detector8 = signal_field_analog_x.read() # fieldAnalogX.get() _tey_norm = detector1/detector2 _trans_norm = detector3/detector2 if dif_series is not None: if setpoint2 == ENERGIES[0]: first = _tey_norm else: dif = _tey_norm-first dif_series.appendData(field_readback,dif) scan.append ([field_readback, setpoint2], [field_readback, readback2], [detector1, detector2, detector3, detector4, detector5, detector6, detector7, detector8, _tey_norm, _trans_norm]) #if field_done.read() == 1: #If not ramping #ramp_done.get() == 1: if abs(field_readback - END_FIELD) < 0.007: print "Field has reached target, breaking execution." break index = index+1 scan.end() if RAMP_RATE is not None: ramp_rate.write(2.0) ramp_rate.waitInPosition(2.0,10000)