Startup
This commit is contained in:
80
script/HystScanStep.py
Normal file
80
script/HystScanStep.py
Normal file
@@ -0,0 +1,80 @@
|
||||
#Parameters
|
||||
"""
|
||||
FIELD = "Hx"
|
||||
RANGES = [(-0.1, 0.1, 0,2),]
|
||||
ENERGIES = (707.90, 703.90)
|
||||
ENERGY_CHANGE_SLEEP = 0.5
|
||||
FIELD_CHANGE_SLEEP = 22.0
|
||||
MODE = 'CIRC +'
|
||||
OFFSET = -1.0
|
||||
"""
|
||||
|
||||
|
||||
FIELD_PRECISION = 0.01
|
||||
field = field_z if FIELD == "Hz" else field_x
|
||||
field_setpoint = Channel (field.channelName, 'd') #Not using energy device to have a blocking write
|
||||
|
||||
#Pre-actions
|
||||
wait_beam()
|
||||
if MODE is not None:
|
||||
pol_mode.write(MODE)
|
||||
if OFFSET is not None:
|
||||
pol_offset.write(OFFSET) #caput('X07MA-ID:ENERGY-OFFS', OFFSET)
|
||||
|
||||
pol_done.waitValue("DONE")
|
||||
|
||||
scan = ManualScan(['field', 'Energy'], ['TEY', 'I0', 'trans', 'polarization', 'polAngle', 'temperature', 'RingCurrent', 'fieldAnalogX', 'tey_norm'] , [0.0, 630.0], [0.1, 638.46], [44, 1])
|
||||
scan.start()
|
||||
|
||||
|
||||
Energy = Channel('X07MA-PHS-E:GO.A', type = 'd')
|
||||
EnergyReadback = Channel('X07MA-PGM:CERBK', type = 'd')
|
||||
|
||||
|
||||
#Dimension 1
|
||||
#RegionPositioner field
|
||||
setpoints = []
|
||||
for r in RANGES:
|
||||
setpoints = setpoints + frange(r[0], r[1], r[2], True)
|
||||
for setpoint1 in setpoints:
|
||||
#PRObably not needed for newer HW
|
||||
"""
|
||||
if setpoint1 == 0.002:
|
||||
caputq('X07MA-PC-PS2:SET:RAMP:TARGET', 'Zero')
|
||||
sleep(6.0)
|
||||
caputq('X07MA-PC-PS2:SET:RAMP:DIR', 'Forward')
|
||||
sleep(6.0)
|
||||
caputq('X07MA-PC-PS2:SET:RAMP:TARGET', 'Lower')
|
||||
sleep(6.0)
|
||||
caputq('X07MA-PC-PS2:SET:DMD:POINT:LOWER', '0.002')
|
||||
sleep(15.0)
|
||||
"""
|
||||
field_setpoint.write(setpoint1)
|
||||
readback1 = field.getPosition()
|
||||
if abs(readback1 - setpoint1) > FIELD_PRECISION : # TODO: Check accuracy
|
||||
raise Exception('Actor field could not be set to the value ' + str(setpoint1))
|
||||
sleep( FIELD_CHANGE_SLEEP ) # TODO: Settling time
|
||||
#Dimension 2
|
||||
#ArrayPositioner Energy
|
||||
for setpoint2 in ENERGIES:
|
||||
Energy.put(setpoint2, timeout=None) # TODO: Set appropriate timeout
|
||||
readback2 = EnergyReadback.get()
|
||||
if abs(readback2 - setpoint2) > 0.1 : # TODO: Check accuracy
|
||||
raise Exception('Actor Energy could not be set to the value ' + str(setpoint2))
|
||||
sleep( ENERGY_CHANGE_SLEEP ) # Settling time
|
||||
|
||||
detector1 = signal_tey.read() #TEY.get()
|
||||
detector2 = signal_i0.read() #I0.get()
|
||||
detector3 = signal_trans.read() #trans.get()
|
||||
detector4 = float(pol_mode.getPositions().index(pol_mode.readback.read())) #polarization.get()
|
||||
detector5 = pol_angle.read() #polAngle.get()
|
||||
detector6 = temperature.read() #temperature.get()
|
||||
detector7 = current.read()
|
||||
detector8 = signal_field_analog_x.read() # fieldAnalogX.get()
|
||||
c = detector1
|
||||
d = detector2
|
||||
tey_norm = detector1/detector2
|
||||
|
||||
scan.append ([setpoint1, setpoint2], [readback1, readback2], [detector1, detector2, detector3, detector4, detector5, detector6, detector7, detector8, tey_norm])
|
||||
|
||||
scan.end()
|
||||
Reference in New Issue
Block a user