diff --git a/script/scan_guard.py b/script/scan_guard.py index d25267a2..e47f7b5a 100644 --- a/script/scan_guard.py +++ b/script/scan_guard.py @@ -722,7 +722,7 @@ class ScanGuard(object): # False = test mode, do not actually send out commands self.controls_active = False # True = beam is okay - self.beam_ok = False + self.beam_ok = True # True while executing the main loop self.running = False # For test and demo, simulate a beam loss after 15 seconds. @@ -850,8 +850,7 @@ class ScanGuard(object): while self.running: self._ringcurrent.pv.poll() #pend_event(timeout=1) - new_beam_ok = self.check_beam() - print "Beam OK= " , new_beam_ok + new_beam_ok = self.check_beam() if new_beam_ok != self.beam_ok: self.beam_ok = new_beam_ok if new_beam_ok: