Files
sf-op/script/Diagnostics/ICTScan_1406.py
2017-06-19 11:07:40 +02:00

125 lines
4.1 KiB
Python

#import ch.psi.pshell.epics.ChannelDouble as ChannelDouble
import ch.psi.pshell.bs.Scalar as Scalar
import ch.psi.pshell.epics.DiscretePositioner as DiscretePositioner
import ch.psi.pshell.epics.ChannelDouble as ChannelDouble
#Arguments
SAMPLES = 100
ICTS = ["SINEG01-DICT215", "S10DI01-DICT025", "SARMA01-DICT090", "SARBD01-DICT030"]
ICTV = ["SINEG01-DICT009:AL1-ICT-VOLTAGE", "S10DI01-DICT113:AL0-ICT-VOLTAGE", "SARMA01-DICT482:AL0-ICT-VOLTAGE","SARBD01-DICT599:AL0-ICT-VOLTAGE"]
BPMS = ["SINEG01-DBPM340:Q1", "S10DI01-DBPM110:Q1", "SARMA01-DBPM100:Q1", "SARBD01-DBPM040:Q1", "SARUN20-DBPM070:Q1"]
#ROT = ["SLGJG-LMRM-M031:MOT.VAL"] # Polarizer
ROT = ["SLGTV-LAPP:SIZE-SET"] # IRIS
#RANGE = [50.0, 15.0]
#STEP_SIZE = 5.0
RANGE = [4.4, 2.0] # IRIS range
STEP_SIZE = 0.1 # IRIS Step size
SETTLING_TIME = 3
SIMULATION = False
do_elog = True
rot_positioners = []
for i in range(len(ROT)):
rot_positioners.append( DummyPositioner("rot " + str(i+1)) if SIMULATION else Channel(ROT[i], alias = "rot" + str(i+1)))
#Stream creation
sensors = []
line_plots = []
st = Stream("pulse_id", dispatcher)
st.setFilter("SIN-CVME-TIFGUN-EVR0:BEAMOK == 1")
for i in range(len(ICTS)):
ict = Scalar("ict" + str(i+1), st, ICTS[i] + ":B1_CHARGE", 1, 0)
av = create_averager(ict, SAMPLES, interval = -1)
av.setMonitored(i>0)
sensors.append(av)
sensors.append(av.stdev)
sensors.append(av.samples)
line_plots.append(av.samples)
for i in range(len(BPMS)):
bpm = Scalar("bpm" + str(i+1), st, BPMS[i], 1, 0)
av1 = create_averager(bpm, SAMPLES, interval = -1)
av1.setMonitored((i>0) or (len(ICTS)>0))
sensors.append(av1)
sensors.append(av1.stdev)
sensors.append(av1.samples)
line_plots.append(av1.samples)
for i in range(len(ICTV)):
"""
ictv = Scalar("ictv" + str(i+1), st, ICTV[i], 1, 0)
av2 = create_averager(ictv, SAMPLES, interval = -1)
av2.setMonitored((i>0) or (len(ICTS)>0))
sensors.append(av2)
sensors.append(av2.stdev)
sensors.append(av2.samples)
"""
ictv = ChannelDouble("ictv" + str(i+1), ICTV[i])
add_device(ictv, True)
ictv.monitored = True
ictv.initialize()
av2 = create_averager(ictv, SAMPLES/2 , interval = -1)
av2.setMonitored(True)
sensors.append(av2)
add_device(av2, True)
#sensors.append(ictv)
#Scalar("beam_ok" , st, "SIN-CVME-TIFGUN-EVR0:BEAMOK" , 1, 0)
st.initialize()
st.start()
st.waitCacheChange(5000) #Wait stream be running before starting scan
"""
#Averaging
aict1 = create_averager(ict1, SAMPLES, interval = -1)
aict2 = create_averager(ict2, SAMPLES, interval = -1)
aict3 = create_averager(ict3, SAMPLES, interval = -1)
aict2.setMonitored(True)
aict3.setMonitored(True)
"""
#Plot setup
setup_plotting( line_plots = line_plots)
#Metadata
set_attribute("/", "Samples" , SAMPLES)
set_attribute("/", "StepSize" , STEP_SIZE)
set_attribute("/", "SamplingTime" , SETTLING_TIME)
set_attribute("/", "Range" , RANGE)
set_attribute("/", "ICTS" , ICTS)
set_attribute("/", "ICTV" , ICTV)
set_attribute("/", "Rot" , ROT)
set_attribute("/", "BPM" , BPMS)
try:
r=lscan(rot_positioners, sensors, [RANGE[0],] * len(rot_positioners), [RANGE[1],] * len(rot_positioners), [STEP_SIZE,] * len(rot_positioners), latency = SETTLING_TIME)
#r=bscan(st, 10)
finally:
st.close()
# save the entry in the logbook
if do_elog:
if get_option("Generated data file:\n" + get_exec_pars().path + "\n\n" + "Save to ELOG?", "YesNo") == "Yes":
gsa_log_msg = "Data file: " + get_exec_pars().path
gsa_log_msg = gsa_log_msg + "\nSamples = " + str(SAMPLES)
gsa_log_msg = gsa_log_msg + "\nStepSize = " + str(STEP_SIZE)
gsa_log_msg = gsa_log_msg + "\nSamplingTime = " + str(SETTLING_TIME)
gsa_log_msg = gsa_log_msg + "\nRange = " + str(RANGE)
gsa_log_msg = gsa_log_msg + "\nICTS = " + str(ICTS)
gsa_log_msg = gsa_log_msg + "\nBPM = " + str(BPMS)
plots = get_plot_snapshots()
save=[]
for i in range(len(ICTS)):
save.append(plots[3*i])
for i in range(len(BPMS)):
save.append(plots[3*i])
elog("Charge scan", gsa_log_msg, save)