From b14c98000b1a4464e3776fa9f4dd532a9078ace1 Mon Sep 17 00:00:00 2001 From: arrell_c Date: Wed, 4 Dec 2024 15:12:09 +0100 Subject: [PATCH] Update SAROP31 PSRD132 --- Athos-spatial-diagnostics/SAROP31-PSRD132.md | 39 +++++++++++++++++++- 1 file changed, 38 insertions(+), 1 deletion(-) diff --git a/Athos-spatial-diagnostics/SAROP31-PSRD132.md b/Athos-spatial-diagnostics/SAROP31-PSRD132.md index 1915193..ffa1f7a 100644 --- a/Athos-spatial-diagnostics/SAROP31-PSRD132.md +++ b/Athos-spatial-diagnostics/SAROP31-PSRD132.md @@ -1,5 +1,42 @@ +# Drawings +- [Overview](http://planarchiv.psi.ch/plandb_pub/p_plandb_cus_pub_sucw.viewItem?pId=248988&pPosInQueryList=1&pCount=9626&pIndexInQueryList=3407&pKrz=&pHg=50024&pUg=&pLnr=&pAnlage=&pBaugruppe=&pBenennung=&pFremdNr=&pGueltig=GUL) +- [Device](http://planarchiv.psi.ch/plandb_pub/p_plandb_cus_pub_sucw.viewItem?pId=248991&pPosInQueryList=1&pCount=1&pIndexInQueryList=1&pKrz=&pHg=50024&pUg=24&pLnr=703&pAnlage=&pBaugruppe=&pBenennung=&pFremdNr=&pGueltig=GUL) +- [MCP & mirror holder](http://planarchiv.psi.ch/plandb_pub/p_plandb_cus_pub_sucw.viewItem?pId=248992&pPosInQueryList=1&pCount=1&pIndexInQueryList=1&pKrz=&pHg=50024&pUg=24&pLnr=704&pAnlage=&pBaugruppe=&pBenennung=&pFremdNr=&pGueltig=GUL) +- [Component list](https://docs.google.com/spreadsheets/d/1eIHDSNPKPg-8OtN0jJKNIQ-7eYLKX2pL0iayO4cNoNo/edit?usp=sharing) +# Detector - Micro channel plate: +Double stack, [F2224-21P159](https://www.hamamatsu.com/eu/en/product/optical-sensors/electron_ion-sensor/mcp/circular_multianode_demountable/F2224.html) 32 mm effective area +# Imaging +- Camera:[ACA1300-60GM CS](https://www.baslerweb.com/de-de/shop/aca1300-60gc/?creative=532311824379&keyword=%2Baca1300-60gc&matchtype=b&network=g&device=c&gad_source=1&gclid=Cj0KCQjwtJKqBhCaARIsAN_yS_mp7pHmpzlgwy-e5SafMKNrnMCxLcLLwKBQtCkyAo_QDMZDA9PuK8kaAn_gEALw_wcB) +- Lens: 35 mm [MVL35M23](https://www.thorlabs.com/thorproduct.cfm?partnumber=MVL35M23) +- Camera serial number: 21574220 +# High voltage set points +- MCP_front set point -1500 V +- Screen set point 3000 V +# High voltage set control +Voltage ramp time from turn on/off approx 2 minutes + +**Turn on** +_MCP front_: `caput SATOP31-PSRD132:CH0-ONOFF-SP 1` +_Screen_: `caput SATOP31-PSRD132:CH1-ONOFF-SP 1` +**Turn off** +_MCP front_: `caput SATOP31-PSRD132:CH0-ONOFF-SP 0` +_Screen_: `caput SATOP31-PSRD132:CH1-ONOFF-SP 0` +# Config +- Image preview PV : SATOP31-PSRD132:FPICTURE +- Trigger currently from SGE-CPCW-B1-EVR0, FrontUnivOut11 + +# Stage positions +- In: 10 mm +- Out:70 mm + +# Triggering +**03.11.23** +- Event: 52 +- Pulser: 6 +- Total delay: 6499.006 + 1003.011 = 7502.017 us +- Width: 5.000 us ## BS setup 4.12.24 Sources list updated -` ,{"stream":"tcp://daqsf-daqsync-17.psi.ch:9004","split":6,"backend":"sf-imagebuffer", "labels": ["SATOP31-PMOS132-2D"], "groups": ["Photonics"]}` +` ,{"stream":"tcp://daqsf-daqsync-17.psi.ch:9004","split":6,"backend":"sf-imagebuffer", "labels": ["SATOP31-PSRD132"], "groups": ["Photonics"]}`