diff --git a/Athos-Intensity-Diagnostics/SATFE10-PDIM067.md b/Athos-Intensity-Diagnostics/SATFE10-PDIM067.md index 864e97e..9632e4c 100644 --- a/Athos-Intensity-Diagnostics/SATFE10-PDIM067.md +++ b/Athos-Intensity-Diagnostics/SATFE10-PDIM067.md @@ -23,8 +23,16 @@ Overview panels: Bias: Bias is from a 9V battery and HV supply filter to the cathode Gain paths: -The signal from the anode passes a signal filter and then a tee. 1 path goes to an amplifier and then a second tee. 1 branch goes to channel 0 -the second brann via 20 dB attenuator to channel 2. the other branch hAS 10 db attenuator. +The signal from the anode passes a signal filter and then a tee. One path goes to an amplifier(20 dB) and then a second tee. One branch goes to channel 0 +The second branch is via a 20 dB attenuator to channel 2. The other branch has a 10 dB attenuator. + +flowchart TD + A[Anode] --> B(20 dB amp) + A --> C(10 dB attenuator) + B --> D[Channel 0] + B -->|20 dB att| E[Channel 2] + C --> F[Channel 3] + The following PVs are the integrated signal waveforms. - SATFE10-LSCP2-FNS:CH1:VAL_GET