@ -5,32 +5,28 @@ The following intensity and position diagnostics are installed in the Aramis FEL
<img src="https://docs.google.com/drawings/d/e/2PACX-1vSUi_Moq5yk7OC--yS0dMFI3A8h-EDZ9fWktFfx_WGW7lJkLWEpS3ky5TfsxJZi-QnkZlN9o19PCecP/pub?w=930&amp;h=182">
> ### Front end
[SARFE10-PBPS053](Aramis-Intensity-Diagnostics/SARFE10-PBPS053)
> ### Optics hutch common
>[SARFE10-PBPS053](Aramis-Intensity-Diagnostics/SARFE10-PBPS053)
> ### Optics hutch Alvra
>[SAROP11-PBPS110](Aramis-Intensity-Diagnostics/SAROP11-PBPS110)
> ### Alvra hutch
>[SAROP11-PBPS122](Aramis-Intensity-Diagnostics/SAROP11-PBPS122)
> ### Optics hutch Bernina
>[SAROP21-PBPS103](Aramis-Intensity-Diagnostics/SAROP21-PBPS103)
> ### Bernina hutch
>[SAROP21-PBPS133](Aramis-Intensity-Diagnostics/SAROP21-PBPS133)
> ### Optics hutch Cristallina
>[SAROP31-PBPS113](Aramis-Intensity-Diagnostics/SAROP31-PBPS113)
> ### Cristallina hutch
>[SAROP31-PBPS149](Aramis-Intensity-Diagnostics/SAROP31-PBPS149)
## Spontaneous radiation detector
**Purpose:** Imaging of spontaneous radiation, primarily for ID commissioning
> ### Optics hutch - Bernina
## Photodiodes
**Purpose:** Detection of low intensity X-rays
# Debug guide