From 70fe5d2af2207d0f3c4f98153d1469a3260c4c8b Mon Sep 17 00:00:00 2001 From: Filip Leonarski Date: Sun, 4 Oct 2026 20:32:03 +0200 Subject: [PATCH] Docs: the footprint stencil reaches 4 sigma Co-Authored-By: Claude Opus 5.5 (1M context) Claude-Session: https://claude.ai/code/session_01K5K8jvPPbmCrbqnWkddTuB --- docs/CPU_DATA_ANALYSIS_INTEGRATION.md | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/docs/CPU_DATA_ANALYSIS_INTEGRATION.md b/docs/CPU_DATA_ANALYSIS_INTEGRATION.md index 17eda627b..bf5046227 100644 --- a/docs/CPU_DATA_ANALYSIS_INTEGRATION.md +++ b/docs/CPU_DATA_ANALYSIS_INTEGRATION.md @@ -108,7 +108,7 @@ What a circular $r_1$ loses is flux, and that loss is **not** a function of reso **Measured spot footprint (automatic).** The radii above are chosen from spots at 5 Å, which at high X-ray energy sit close to the beam. Away from it a spot can grow several times wider — radially from the sensor's parallax and the obliquity of the incidence, tangentially from the crystal's azimuthal spread, which rotates the diffracted beam about the incident one and smears the spot along its ring. On small-molecule data at 20–25 keV the standard deviation grows from ~1 px near the beam to ~5 px at the detector edge: the $r_1 = 4$ disk holds a quarter of the flux there, the $6\ldots13$ px ring a third of it, and the profile widths learned inside $r_1$ (§9.3) saturate near $r_1^2/4$. So the pre-scan measures every spot it finds with a window that follows the spot — three of its own standard deviations, iterated and re-centred — separately along and across the radius, and tabulates the median widths $\sigma_ ho,\sigma_ au$ against the distance from the beam. Wherever $3\max(\sigma_ -ho,\sigma_ au)>r_1$ the integrator then (i) starts the background ring at $3\sigma$ along each axis, (ii) sums the reflection over the $r_1$ disk **and** the $3\sigma$ footprint ellipse, so the summation — the profile fit's seed and its fallback — holds the spot rather than its core, and (iii) builds the per-reflection Gaussian at the measured widths on a grid grown to hold them. Where every spot fits the disk nothing is installed and the integration is unchanged bit for bit, which is the case for compact protein spots; like the measured radius, the footprint applies to the canonical pass and not to the geometry pre-pass, and a canonical pass whose wider rings the neighbours starve falls back to the settings without it. Judged by refining the published structures with SHELXL, it removes the intensity loss that grew with resolution on the small-molecule sets (rugnux/model intensity in the outermost shell 0.81–0.91 → 0.98–1.02). +ho,\sigma_ au)>r_1$ the integrator then (i) starts the background ring at $4\sigma$ along each axis, (ii) sums the reflection over the $r_1$ disk **and** the $4\sigma$ footprint ellipse, so the summation — the profile fit's seed and its fallback — holds the spot rather than its core, and (iii) builds the per-reflection Gaussian at the measured widths on a grid grown to hold them. Where every spot fits the disk nothing is installed and the integration is unchanged bit for bit, which is the case for compact protein spots; like the measured radius, the footprint applies to the canonical pass and not to the geometry pre-pass, and a canonical pass whose wider rings the neighbours starve falls back to the settings without it. The reach is $4\sigma$ rather than the $3\sigma$ that decides whether a spot outgrew the disk because wide spots are not Gaussian: mosaic streaks and diffuse halos carry flux past $3\sigma$, which a ring starting there reads as background. Judged by refining the published structures with SHELXL, it removes the intensity loss that grew with resolution on the small-molecule sets (rugnux/model intensity in the outermost shell 0.81–0.91 → 0.98–1.02). ### 9.2 Box summation (seed and fallback)