The play/pause toggle ran its start-time checks (beamline state, busy, baton,
maintenance) before the pause branch, so when running you could be blocked from
pausing if the beamline was in the wrong state or busy.
Handle the pause toggle first and return immediately (unconditional), and run
the start-condition gates only when starting/resuming from paused.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
- promote crystal score to its own RasterGridMetric.RASTER_SCORE; first and
default metric in the GUI dropdown; restore PR to original "Profile Radius"
- send per-cell raster score to AareDB via RasterPayloadModel
- split raster_highest_score (compute_crystal_score_array) from
raster_centre_of_mass (restored to ndimage.center_of_mass); use score-based
targeting for where-to-collect in both simulation and real mode
- add tests covering compute_crystal_score_array and raster_highest_score
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
BeamlineBusyException / TellCommandWhileBusyException fire when a user triggers
an action while the beamline or robot is busy. These are blocking-but-benign
("you can't do that right now"), so route them to the log + status bar instead
of a modal pop-up (and without the defensive automation pause), regardless of
the exception's critical flag. Genuine failures (e.g. No Pin in Gripper) still
get the modal.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Fix the GUI pop-up path and add personnel-safety-system (PSS) gating so
door-open / beam-down / shutter-closed conditions are surfaced and acted on.
- exception pop-ups: connect the previously-orphaned http_error signal;
failed user operations now raise a modal dialog, background/polling errors
a non-modal banner.
- PSS device (devices/pss_state.py) reading EH1-PSYS PROHIBITED-STATE /
ALARM-STATE; new critical DoorSafetyError + DOOR_SAFETY_ERROR code.
- mounting service blocks mount/unmount when the hutch is not prohibited or
an alarm is active; /status now publishes pss_prohibited / pss_alarm.
- GUI blocks manual mount/unmount and the automation Run button immediately
(pop-up) on door-open, and shows a warning banner while an alarm is active.
- centralise per-action precondition checks (ring current, safety shutter,
hutch door) into one combined "continue?" dialog with a session-global
"don't ask again for 1 hour" snooze, applied to all data-collection buttons.
- live automation pauses and auto-resumes on bad conditions (beam, shutter,
door, robot) with continue-now / stop overrides, gated by a default-on
"Pause on bad conditions" checkbox replacing the dead CHECK_ENABLED constant.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add DbOverrideLineEdit: a numeric field holding both a database value and
the user's value, driven by a per-tab Database/User-values toggle. The
user's value persists across samples, can be reverted to the database
value, and recovered again - replacing the clunky per-field checkboxes.
Fix the dtz<->resolution coupling so editing one updates the other in both
Database and User modes (previously it broke whenever a value was
overridden). Wire resolution, detector distance, transmission, exposure,
rotation total/image angle and the raster grid element size through the
new widget; other panels are untouched.
Add tests covering persist/revert/recover, the toggle's downstream emit,
the dtz/resolution coupling in both modes, and cross-sample persistence.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>