Files
ecmc_plugin_grbl/doc/csv/build_option_codes_en_US.csv
Sonny Jeon fd2a4ebaee Fixed shared build info code.
- The build info options of “two switches on an axis” and “homing init
lock” shared the same letter ‘L’. The former is now ’T’.
2017-02-27 15:24:51 -07:00

933 B

1OPT: Code Build-Option DescriptionState
2VVariable spindleEnabled
3NLine numbersEnabled
4MMist coolant M7Enabled
5CCoreXYEnabled
6PParking motionEnabled
7ZHoming force originEnabled
8HHoming single axis commandsEnabled
9TTwo limit switches on axisEnabled
10AAllow feed rate overrides in probe cyclesEnabled
11DUse spindle direction as enable pinEnabled
120Spindle enable off when speed is zeroEnabled
13SSoftware limit pin debouncingEnabled
14RParking override controlEnabled
15*Restore all EEPROM commandDisabled
16$Restore EEPROM `$` settings commandDisabled
17#Restore EEPROM parameter data commandDisabled
18IBuild info write user string commandDisabled
19EForce sync upon EEPROM writeDisabled
20WForce sync upon work coordinate offset changeDisabled