305 lines
5.1 KiB
INI
305 lines
5.1 KiB
INI
[Bruker_CF6]
|
|
cascade = T1:CF6_ls340,B1:bruker_bec1,sample_stage:normal_sample_stage
|
|
enabled = False
|
|
[Default]
|
|
cascade = sample_stage:normal_sample_stage
|
|
enabled = True
|
|
[Knauer and Syringe]
|
|
cascade = HPLC:knauer_01,Syringe:syringe,sample_stage:normal_sample_stage
|
|
enabled = False
|
|
[Knauer, Syringe and MVP]
|
|
cascade = HPLC:knauer_01,Syringe:syringe,MVP:mvp,sample_stage:normal_sample_stage
|
|
enabled = False
|
|
[B1]
|
|
datype = B
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = ma1
|
|
optype = magnetic_field
|
|
[Function_Generator]
|
|
datype = V
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = pulser
|
|
optype = function_generator
|
|
[HPLC]
|
|
datype = pump
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = hplc
|
|
optype = hplc
|
|
[High_Voltage]
|
|
datype = V
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = hv_val
|
|
optype = multimeter
|
|
[I1]
|
|
datype = I
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = curr1
|
|
optype = multimeter
|
|
[I2]
|
|
datype = I
|
|
enabled = False
|
|
id = 2
|
|
implementation = none
|
|
name = curr2
|
|
optype = multimeter
|
|
[MVP]
|
|
datype = valve
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = mvp
|
|
optype = valve
|
|
[Power Supply]
|
|
datype = V
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = power_supply
|
|
optype = power_supply
|
|
[Syringe]
|
|
datype = pump
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = syr
|
|
optype = syringe
|
|
[T1]
|
|
datype = T
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = tc1
|
|
optype = temperature
|
|
[T2]
|
|
datype = T
|
|
enabled = False
|
|
id = 2
|
|
implementation = none
|
|
name = tc2
|
|
optype = temperature
|
|
[T3]
|
|
datype = T
|
|
enabled = False
|
|
id = 3
|
|
implementation = none
|
|
name = tc3
|
|
optype = temperature
|
|
[T4]
|
|
datype = T
|
|
enabled = False
|
|
id = 4
|
|
implementation = none
|
|
name = tc4
|
|
optype = temperature
|
|
[T5]
|
|
datype = T
|
|
enabled = False
|
|
id = 5
|
|
implementation = none
|
|
name = tc5
|
|
optype = temperature
|
|
[T6]
|
|
datype = T
|
|
enabled = False
|
|
id = 6
|
|
implementation = none
|
|
name = tc6
|
|
optype = temperature
|
|
[V1]
|
|
datype = V
|
|
enabled = False
|
|
id = 1
|
|
implementation = none
|
|
name = volts1
|
|
optype = multimeter
|
|
[V2]
|
|
datype = V
|
|
enabled = False
|
|
id = 2
|
|
implementation = none
|
|
name = volts2
|
|
optype = multimeter
|
|
[sample_stage]
|
|
enabled = Always
|
|
implementation = normal_sample_stage
|
|
name = sample_stage
|
|
optype = motion_axis
|
|
[5Tmagnet]
|
|
desc = "The New Zealand magnet"
|
|
driver = tsi_smc
|
|
imptype = magnetic_field
|
|
ip = 137.157.202.151
|
|
port = 4004
|
|
timeout = 2000
|
|
|
|
[CF6_ls340]
|
|
desc = "cf6: Bottom loading cryocooler"
|
|
driver = "ls340"
|
|
imptype = temperature
|
|
ip = 10.157.205.38
|
|
port = 4001
|
|
terminator = \r\n
|
|
tol1 = 0.2
|
|
tol2 = 0.2
|
|
|
|
[agilent_33220A]
|
|
asyncqueue = sct
|
|
desc = "Function Generator"
|
|
driver = agilent_33220A
|
|
imptype = function_generator
|
|
ip = 10.157.205.16
|
|
port = 5025
|
|
|
|
[bruker_bec1]
|
|
desc = "Bruker Magnet"
|
|
driver = "bruker"
|
|
imptype = magnetic_field
|
|
ip = 10.157.205.13
|
|
port = 4444
|
|
tol = 0.1
|
|
|
|
[hiden_xcs]
|
|
desc = "Hiden XCS Relative Humidity Flow Control"
|
|
driver = "hiden_xcs"
|
|
imptype = flowcontrol
|
|
ip = 137.157.202.151
|
|
port = 4001
|
|
|
|
[isotech_ps]
|
|
desc = "Isotech Power Supply:Baud=2400,Data=8,Stop=1,Parity=None,Flow=None"
|
|
driver = "isotech_ps"
|
|
imptype = power_supply
|
|
ip = 137.157.202.151
|
|
port = 4001
|
|
|
|
[knauer_01]
|
|
asyncprotocol = knauer_ap
|
|
desc = "Knauer BlueShadow Pump 40P (High Performance/Pressure Liquid Chromatography)"
|
|
driver = knauer_pump
|
|
imptype = hplc
|
|
ip = 10.157.205.51
|
|
port = 10001
|
|
timeout = 1000
|
|
|
|
[ls336_01]
|
|
asyncqueue = sct
|
|
desc = "Lakeshore 336 temperature controller"
|
|
driver = "ls336"
|
|
imptype = temperature
|
|
ip = 10.157.205.28
|
|
port = 7777
|
|
terminator = \r\n
|
|
tol1 = 1.0
|
|
tol2 = 1.0
|
|
|
|
[ls336_02]
|
|
asyncqueue = sct
|
|
desc = "Lakeshore 336 temperature controller"
|
|
driver = "ls336"
|
|
imptype = temperature
|
|
ip = 10.157.205.29
|
|
port = 7777
|
|
terminator = \r\n
|
|
tol1 = 1.0
|
|
tol2 = 1.0
|
|
|
|
[ls336_04]
|
|
asyncqueue = sct
|
|
desc = "Lakeshore 336 temperature controller"
|
|
driver = "ls336"
|
|
imptype = temperature
|
|
ip = 10.157.205.30
|
|
port = 7777
|
|
terminator = \r\n
|
|
tol1 = 1.0
|
|
tol2 = 1.0
|
|
|
|
[ls336_12]
|
|
asyncqueue = sct
|
|
desc = "Lakeshore 336 temperature controller"
|
|
driver = "ls336"
|
|
imptype = temperature
|
|
ip = 10.157.205.31
|
|
port = 7777
|
|
terminator = \r\n
|
|
tol1 = 1.0
|
|
tol2 = 1.0
|
|
|
|
[mercury_scpi_01]
|
|
desc = "Oxford Mercury temperature controller in Mercury mode"
|
|
driver = "mercury_scpi"
|
|
imptype = temperature
|
|
ip = 10.157.205.5
|
|
permlink = LT
|
|
port = 7020
|
|
terminator = \r\n
|
|
tol = 1.0
|
|
valve_tol = 2
|
|
|
|
[mercury_scpi_02]
|
|
desc = "Oxford Mercury temperature controller in Mercury mode"
|
|
driver = "mercury_scpi"
|
|
imptype = temperature
|
|
ip = 10.157.205.47
|
|
permlink = LT
|
|
port = 7020
|
|
terminator = \r\n
|
|
tol = 1.0
|
|
valve_tol = 2
|
|
|
|
[mvp]
|
|
desc = "Valve controller"
|
|
driver = mvp_valve
|
|
imptype = valve
|
|
ip = 137.157.202.151
|
|
port = 4004
|
|
|
|
[normal_sample_stage]
|
|
desc = "This is the default sample stage configuration xyz translation omega rotation but no tilt axes"
|
|
imptype = motion_axis
|
|
|
|
[platypus_julabo]
|
|
ctrl_sensor = "bath"
|
|
desc = "Julabo temperature controller"
|
|
driver = "julabo_lh45"
|
|
imptype = temperature
|
|
ip = 137.157.202.151
|
|
port = 4002
|
|
tol = 2.0
|
|
type = T
|
|
|
|
[protek_01]
|
|
asyncqueue = sct
|
|
desc = "Protek Multimeter"
|
|
driver = "protekmm"
|
|
imptype = multimeter
|
|
ip = 10.157.205.36
|
|
port = 4001
|
|
|
|
[protek_02]
|
|
asyncqueue = sct
|
|
desc = "Protek Multimeter"
|
|
driver = "protekmm"
|
|
imptype = multimeter
|
|
ip = 10.157.205.37
|
|
port = 4001
|
|
|
|
[syringe]
|
|
desc = "Syringe Pump"
|
|
driver = syringe_pump
|
|
imptype = syringe
|
|
ip = 137.157.202.151
|
|
port = 4003
|
|
timeout = 1000
|
|
|