# Author: Ferdi Franceschini (ffr@ansto.gov.au)
namespace eval ::environment::temperature { }
# @brief Make a simulated temperature controller object.
#
# @param temp_sobj, name for temperature controller object.
proc ::environment::temperature::mkwest400sim {temp_sobj} {
EvFactory new $temp_sobj sim
sicslist setatt $temp_sobj numsensors 1
sicslist setatt $temp_sobj controlsensor sensora
sicslist setatt $temp_sobj sensorlist sensora
sicslist setatt $temp_sobj units kelvin
sicslist setatt $temp_sobj klass @none
}
#WEST4100 tempcontroller creation
proc ::environment::temperature::mkwest400 {temp_sobj IP ID} {
MakeRS232Controller sertemp $IP 502
sertemp timeout 300
sertemp sendterminator 0x0
sertemp replyterminator 0x0
#ffr 2014-09-22: The modbus addr should be 1 for single port moxas (Not $ID which is a SICS ID)
# EvFactory new tc1 west4100 sertemp $ID 2
EvFactory new $temp_sobj west4100 sertemp 1 2
sicslist setatt $temp_sobj units kelvin
sicslist setatt $temp_sobj klass @none
}
# @brief Adds a west400 temperature controller object.
#
# This must be called when the instrument configuration is loaded and before\n
# the buildHDB function is called. Currently there is no way to add and remove\n
# environment controllers and their hdb paths at runtime.
proc ::environment::temperature::add_west4100 {IP ID} {
set sim_mode [SplitReply [environment_simulation]]
if {$sim_mode == "true"} {
::environment::temperature::mkwest400sim tc1
} else {
::environment::temperature::mkwest400 tc1 $IP $ID
tc1 Upperlimit 1500
tc1 Lowerlimit 0
tc1 tolerance 10
}
sicslist setatt tc1 environment_name tc1
sicslist setatt tc1 long_name control_sensor_reading
::environment::mkenvinfo tc1 {ramprate {priv user} powerlimit {priv manager} }