scan_common_t.tcl Remove redundant filename entries from bmonscan and hmscan feedback reflectometer/config/parameters/parameters.tcl Put instrument parameters under hdb parameters section a la Quokka r2645 | ffr | 2008-07-11 11:42:52 +1000 (Fri, 11 Jul 2008) | 7 lines
28 lines
522 B
Tcl
28 lines
522 B
Tcl
##
|
|
# @brief Instrument parameters
|
|
# TODO There should be an NXgeometry entry for each distance, and linked to an NXgeometry
|
|
# entry for the chopper [SICS-108].
|
|
foreach vn {
|
|
detector_distance
|
|
detector_base
|
|
slit4_distance
|
|
slit4_base
|
|
sample_distance
|
|
sample_base
|
|
slit3_distance
|
|
slit3_base
|
|
} {
|
|
::utility::mkVar $vn float manager $vn true parameter true true
|
|
}
|
|
|
|
detector_distance 10000
|
|
detector_base 300
|
|
slit4_distance 6000
|
|
slit4_base 20
|
|
sample_distance 5800
|
|
sample_base 50
|
|
slit3_distance 5600
|
|
slit3_base 20
|
|
|
|
|