<html>
|
|
<head>
|
|
<title>SICS Variables</title>
|
|
</head>
|
|
<body>
|
|
<h2>SICS Variables </h2>
|
|
<p>
|
|
In SICS most parameters necessary for instrument control are kept with the SICS
|
|
object implementing the functionality. However, there are some odd bits of
|
|
information which need to be known, mostly additional information about and
|
|
from the user, which should go into data files. Such information is kept in
|
|
SICS variables, created with the command VarMake detailed below.
|
|
</p>
|
|
<p>
|
|
Variables are also used in order to control the SINQ automatic file name
|
|
creation scheme for data files. At SINQ, data files are put into a special
|
|
directory. The actual name consists of a prefix, a sequential number, the
|
|
last two digits of the year and an ending. All these components are
|
|
controlled by variables.
|
|
</p>
|
|
<p>
|
|
The exact syntax for creating variables looks like this:
|
|
<ul>
|
|
<li> <b> VarMake name type access </b> creates a simple variable name. The
|
|
variable type can be Text, Int or Float. The access parameter defines who
|
|
may may change the variable. Possible values are: Internal, Manager, User
|
|
and Spy.
|
|
</ul>
|
|
</p>
|
|
<p>
|
|
There are quite a few SICS variables which have special usages and should be
|
|
present. Some of them may need to be set by the user, all of them should be
|
|
inspectable by the user. Many of these variables are used when writing
|
|
NeXus data files. These special variables are:
|
|
<DL>
|
|
<DT> sample
|
|
<DD> The sample name. To be set by the user.
|
|
<DT> title.
|
|
<DD> The experiment title.
|
|
<DT> User
|
|
<DD> The name of the user to be specified in a data file.
|
|
<DT> Instrument.
|
|
<DD> The name of the instrument.
|
|
<DT> SicsDataPath
|
|
<DD>The full path name of the instruments data directory. Should have a / at
|
|
the end.
|
|
<DT> SicsDataPrefix
|
|
<DD> The prefix to use for data file names.
|
|
<DT> SicsDataPostFix
|
|
<DD> The ending to use for the data file name. Including the '.'.
|
|
<DT> Adress
|
|
<DD> The users adress.
|
|
<DT> phone
|
|
<DD> The users phone number.
|
|
<DT> email
|
|
<DD> The users e-mail adress.
|
|
<DT> fax
|
|
<DD> The users fax number.
|
|
</DL>
|
|
</p>
|
|
<p>
|
|
Some of the variables stated above should never be changed by a user. This
|
|
can be achieved by the variable lock command described in the user
|
|
documentation.
|
|
</p>
|
|
</body>
|
|
</html> |