[12tmagnet_setup] cascade = B1:12tmagnet_oxford,sample_stage:12tmagnet_sample_insert,T1:mercury_scpi_01 enabled = False [Autolab_setup] cascade = sample_stage:normal_sample_stage,I1:protek_01,V1:protek_02 enabled = False [CF1] cascade = T1:CF1_ls340,sample_stage:normal_sample_stage enabled = False [CF8] cascade = T1:ls336_01,T2:ls340_11,sample_stage:normal_sample_stage enabled = False [Default] cascade = sample_stage:normal_sample_stage enabled = True [B1] datype = B enabled = False id = 1 implementation = none name = magnet1 optype = magnetic_field [Function_Generator] datype = V enabled = False id = 1 implementation = none name = pulser optype = function_generator [I1] datype = I enabled = False id = 1 implementation = none name = curr1 optype = multimeter [I2] datype = I enabled = False id = 2 implementation = none name = curr2 optype = multimeter [T1] datype = T enabled = False id = 1 implementation = none name = tc1 optype = temperature [T2] datype = T enabled = False id = 2 implementation = none name = tc2 optype = temperature [T3] datype = T enabled = False id = 3 implementation = none name = tc3 optype = temperature [T4] datype = T enabled = False id = 4 implementation = none name = tc4 optype = temperature [T5] datype = T enabled = False id = 5 implementation = none name = tc5 optype = temperature [T6] datype = T enabled = False id = 6 implementation = none name = tc6 optype = temperature [V1] datype = V enabled = False id = 1 implementation = none name = volts1 optype = multimeter [V2] datype = V enabled = False id = 2 implementation = none name = volts2 optype = multimeter [sample_stage] enabled = Always implementation = normal_sample_stage name = sample_stage optype = motion_axis [12tmagnet_oxford] asyncqueue = sct desc = "12 Tesla Oxford Magnet" driver = "oxford12tlv" imptype = magnetic_field interval = 5 ip = 10.157.205.3 port = 55001 [12tmagnet_sample_insert] desc = "som will be redefined as the magnet sample insert rotation. Sample stage will be renamed to somss" imptype = motion_axis [CF1_ls340] desc = "cf1: Bottom loading cryofurnace" driver = "ls340" imptype = temperature ip = 10.157.205.43 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [agilent_33220A] asyncqueue = sct desc = "Function Generator" driver = agilent_33220A imptype = function_generator ip = 10.157.205.16 port = 5025 [eularian_cradle] desc = "Load the Eulerian cradle configuration" imptype = motion_axis [ls336_01] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.28 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_02] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.29 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_04] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.30 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_05] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 137.157.201.21 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_06] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.30 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_11] desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.27 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_12] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.31 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_01] asyncqueue = sct desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_02] asyncqueue = sct desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4002 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_11] desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls370_1] desc = "Lakeshore 370 Resistance Bridge" driver = "lakeshore_m370" imptype = temperature ip = 10.157.205.42 port = 4001 tol = 1.0 [mercury_01] assoc = 00000124 cards = HHHVLTTP desc = "Oxford Mercury temperature controller (12T)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.5 port = 7020 ptol = 5 terminator = \n ttol = 1.0 vtol = 5 [mercury_02] assoc = 00000124 cards = HHTVTTTP desc = "Oxford Mercury temperature controller (CF10)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.46 port = 7020 ptol = 5 terminator = \n ttol = 1.0 vtol = 5 [mercury_03] assoc = 00000123 cards = HHHNNTTT desc = "Oxford Mercury temperature controller ()" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.47 port = 7020 ptol = 5 terminator = \n ttol = 1.0 vtol = 5 [normal_sample_stage] desc = "This is the default sample stage configuration with xy translation and phi and chi tilt stages" imptype = motion_axis [protek_01] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.36 port = 4001 [protek_02] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.37 port = 4001 [small_omega] desc = "Load the small omega configuration" imptype = motion_axis [vf1_west4100] asyncprotocol = modbus_ap desc = "VF1 Blue furnace temperature controller" dev_id = 1 driver = "west_6100" imptype = temperature ip = 10.157.205.24 port = 502 [vf2_west4100] asyncprotocol = modbus_ap desc = "VF2 Blue furnace temperature controller" dev_id = 1 driver = "west_6100" imptype = temperature ip = 10.157.205.25 port = 502