[Bruker_CF6] cascade = T1:CF6_ls340,B1:bruker_bec1,sample_stage:normal_sample_stage enabled = False [Default] cascade = sample_stage:normal_sample_stage enabled = True [Knauer and Syringe] cascade = HPLC:knauer_01,Syringe:syringe,sample_stage:normal_sample_stage enabled = False [Knauer, Syringe and MVP] cascade = HPLC:knauer_01,Syringe:syringe,MVP:mvp,sample_stage:normal_sample_stage enabled = False [B1] datype = B enabled = False id = 1 implementation = none name = ma1 optype = magnetic_field [Function_Generator] datype = V enabled = False id = 1 implementation = none name = pulser optype = function_generator [HPLC] datype = pump enabled = False id = 1 implementation = none name = hplc optype = hplc [High_Voltage] datype = V enabled = False id = 1 implementation = none name = hv_val optype = multimeter [I1] datype = I enabled = False id = 1 implementation = none name = curr1 optype = multimeter [I2] datype = I enabled = False id = 2 implementation = none name = curr2 optype = multimeter [MVP] datype = valve enabled = False id = 1 implementation = none name = mvp optype = valve [Power Supply] datype = V enabled = False id = 1 implementation = none name = power_supply optype = power_supply [Syringe] datype = pump enabled = False id = 1 implementation = none name = syr optype = syringe [T1] datype = T enabled = False id = 1 implementation = none name = tc1 optype = temperature [T2] datype = T enabled = False id = 2 implementation = none name = tc2 optype = temperature [T3] datype = T enabled = False id = 3 implementation = none name = tc3 optype = temperature [T4] datype = T enabled = False id = 4 implementation = none name = tc4 optype = temperature [T5] datype = T enabled = False id = 5 implementation = none name = tc5 optype = temperature [T6] datype = T enabled = False id = 6 implementation = none name = tc6 optype = temperature [V1] datype = V enabled = False id = 1 implementation = none name = volts1 optype = multimeter [V2] datype = V enabled = False id = 2 implementation = none name = volts2 optype = multimeter [sample_stage] enabled = Always implementation = normal_sample_stage name = sample_stage optype = motion_axis [5Tmagnet] desc = "The New Zealand magnet" driver = tsi_smc imptype = magnetic_field ip = 137.157.202.151 port = 4004 timeout = 2000 [CF6_ls340] desc = "cf6: Bottom loading cryocooler" driver = "ls340" imptype = temperature ip = 10.157.205.38 port = 4001 terminator = \r\n tol1 = 0.2 tol2 = 0.2 [agilent_33220A] asyncqueue = sct desc = "Function Generator" driver = agilent_33220A imptype = function_generator ip = 10.157.205.16 port = 5025 [bruker_bec1] desc = "Bruker Magnet" driver = "bruker" imptype = magnetic_field ip = 10.157.205.13 port = 4444 tol = 0.1 [hiden_xcs] desc = "Hiden XCS Relative Humidity Flow Control" driver = "hiden_xcs" imptype = flowcontrol ip = 137.157.202.151 port = 4001 [isotech_ps] desc = "Isotech Power Supply:Baud=2400,Data=8,Stop=1,Parity=None,Flow=None" driver = "isotech_ps" imptype = power_supply ip = 137.157.202.151 port = 4001 [knauer_01] asyncprotocol = knauer_ap desc = "Knauer BlueShadow Pump 40P (High Performance/Pressure Liquid Chromatography)" driver = knauer_pump imptype = hplc ip = 10.157.205.51 port = 10001 timeout = 1000 [ls336_01] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.28 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_02] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.29 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_04] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.30 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_12] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.31 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [mercury_01] assoc = 00000124 cards = HHHVLTTP desc = "Oxford Mercury temperature controller (12T)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.5 port = 7020 ptol = 5 terminator = \n timeout = 2000 ttol = 1.0 vtol = 5 [mercury_02] assoc = 00000124 cards = HHTVTTTP desc = "Oxford Mercury temperature controller (CF10)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.46 port = 7020 ptol = 5 terminator = \n timeout = 2000 ttol = 1.0 vtol = 5 [mercury_03] assoc = 00000123 cards = HHHNNTTT desc = "Oxford Mercury temperature controller ()" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.47 port = 7020 ptol = 5 terminator = \n timeout = 2000 ttol = 1.0 vtol = 5 [mvp] desc = "Valve controller" driver = mvp_valve imptype = valve ip = 137.157.202.151 port = 4004 [normal_sample_stage] desc = "This is the default sample stage configuration xyz translation omega rotation but no tilt axes" imptype = motion_axis [platypus_julabo] ctrl_sensor = "bath" desc = "Julabo temperature controller" driver = "julabo_lh45" imptype = temperature ip = 137.157.202.151 port = 4002 tol = 2.0 type = T [protek_01] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.36 port = 4001 [protek_02] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.37 port = 4001 [syringe] desc = "Syringe Pump" driver = syringe_pump imptype = syringe ip = 137.157.202.151 port = 4003 timeout = 1000