# -------------------------------------------------------------------------- # Initialization script for DMC at SINQ, SICS server. # # Dr. Mark Koennecke Juli 1997 #--------------------------------------------------------------------------- # O P T I O N S set auto_path "/home/DMC/bin" # first all the server options are set ServerOption ReadTimeOut 100 # timeout when checking for commands. In the main loop SICS checks for # pending commands on each connection with the above timeout, has # PERFORMANCE impact! ServerOption AcceptTimeOut 100 # timeout when checking for connection req. # Similar to above, but for connections ServerOption ReadUserPasswdTimeout 500000 # time to wiat for a user/passwd to be sent from a client. Increase this # if there is a problem connecting to a server due to network overload\ ServerOption LogFileBaseName "/home/DMC/log/dmclog" # the path and base name of the internal server logfile to which all # activity will be logged. ServerOption ServerPort 3006 # the port number the server is going to listen at. The client MUST know # this number in order to connect. It is in client.ini ServerOption StatusFile /home/DMC/log/status.tcl ServerOption InterruptPort 3007 # The UDP port where the server will wait for Interrupts from clients. # Obviously, clients wishing to interrupt need to know this number. # Telnet Options ServerOption TelnetPort 1301 ServerOption TelWord sicslogin #The UDP port for sending quieck messages, telling the world of new data ServerOption QuieckPort 2108 #the token system + the token force grab password TokenInit connan #--------------------------------------------------------------------------- # U S E R S # than the SICS users are specified # Syntax: SicsUser name password userRightsCode SicsUser Manager Lucas 1 SicsUser lnsmanager lnsSICSlns 1 SicsUser User DMC 2 SicsUser lnsuser 98lns2 2 SicsUser Spy 007 3 #-------------------------------------------------------------------------- # D E V I C E S : M O T O R S #Motor a4 EL734 LNSP22 4000 5 6 # EL734 motor with parameters: hostname PortNumber Channel MotorID # Motor nam SIM -20. 20. 5. 1.0 # Simulated motor with name nam, lower limit -20, upper limit +20, # error ratio 5% and speed 1.0. Speed may be omitted # Monochromator motors ClientPut "Installing Motors" Motor OmegaM EL734 lnsp19.psi.ch 4000 2 1 Motor TwoThetaM EL734 lnsp19.psi.ch 4000 2 2 Motor MonoX EL734 lnsp19.psi.ch 4000 2 5 Motor MonoY EL734 lnsp19.psi.ch 4000 2 6 Motor CurveM EL734 lnsp19.psi.ch 4000 2 9 Motor MonoPhi EL734 lnsp19.psi.ch 4000 2 7 Motor MonoChi EL734 lnsp19.psi.ch 4000 2 8 # sample Table Motor Table EL734 lnsp19.psi.ch 4000 2 3 Motor TwoThetaD EL734 lnsp19.psi.ch 4000 2 4 #-------------------------------------------------------------------------- # Configure Detector # needs a EL737 or simualation for count control ClientPut "Installing counter" MakeCounter counter EL737 lnsp19.psi.ch 4000 4 counter SetExponent 6 MakeHM banana SINQHM banana configure HistMode Normal banana configure OverFlowMode Ceil banana configure Rank 1 banana configure Length 400 banana configure BinWidth 4 banana preset 100. banana CountMode Timer banana configure HMComputer lnse01.psi.ch banana configure HMPort 2400 banana configure Counter counter banana init banana exponent 6 #-------------------------------------------------------------------------- # V A R I A B L E S # now a few general variables are created # Syntax: VarMake name type access # type can be one of: Text, Int, Float #access can be one of: Internal, Mugger, User, Spy VarMake SicsDataPath Text Internal SicsDataPath "/home/DMC/data/" VarMake DetStepWidth Float Internal DetStepWidth 0.2 DetStepWidth lock VarMake Instrument Text Internal Instrument "DMC" Instrument lock #initialisation VarMake Title Text User VarMake User Text User VarMake Collimation Text User VarMake Sample Text User Sample Kellerit VarMake comment1 Text User VarMake comment2 Text User VarMake comment3 Text User VarMake SicsDataPrefix Text Internal SicsDataPrefix dmc #--------- make data number MakeDataNumber SicsDataNumber /home/DMC/data/DataNumber VarMake SicsDataPostFix Text Internal SicsDataPostFix ".hdf" VarMake Adress Text User VarMake phone Text User VarMake fax Text User VarMake email Text User VarMake sample_mur Float User # Monochromator variables # Syntax MakeMono name type OmegaMotor 2ThetaMotor CurveMotor1 CurveMotor2 MakeMono Mono "Ge-111" OmegaM TwoThetaM Mono DD 3.3537 # Syntax MakeWaveLength name MonochromatorToUse MakeWaveLength lambda Mono #-------------------------------------------------------------------------- # P R O C E D U R E S # create the drive command MakeDrive #start RuenBuffer system MakeRuenBuffer # aliases SicsAlias OmegaM A1 SicsAlias TwoThetaM A2 SicsAlias Table A3 SicsAlias TwoThetaD A4 SicsAlias MonoX A5 SicsAlias MonoY A6 SicsAlias MonoPhi A7 SicsAlias MonoChi A8 SicsAlias CurveM A9 InitDMC #----- The Logbook stuff source "/home/DMC/bin/log.tcl" Publish LogBook Spy #------ The count command source "/home/DMC/bin/count.tcl" Publish count User Publish Repeat User #------ The scan command for Managers source "/home/DMC/bin/scan.tcl" Publish scan Mugger #---------install beam command source beamdt.tcl